Description
ABS DWV P-Trap W/ Plug (HUB x HUB x Cleanout W/ Plug)
ABS DWV P-Traps with Cleanout Plug create a water seal to help block sewer gases while also providing convenient access for cleaning, inspection, and maintenance.
Featuring hub connections on the inlet and outlet plus a cleanout opening with removable plug, this fitting is designed for non-pressure ABS drain, waste, and vent systems. The curved trap body retains water to form the trap seal, while the cleanout plug provides a service-access point for clearing debris or inspecting the trap without cutting apart the piping system. Manufactured for ABS DWV service, it meets recognized standards including ASTM D2661, CSA B181.1, and NSF Standard 14.
Product Highlights
- ABS DWV P-trap with cleanout plug
- HUB x HUB x Cleanout with Plug configuration
- Hub connections on inlet and outlet
- Includes a removable cleanout plug
- Creates a water seal in the drainage line
- Helps prevent sewer gases from entering occupied spaces
- Provides convenient cleaning and maintenance access
- Allows trap servicing without cutting the piping system
- Supports efficient wastewater drainage
- Hub connections accept compatible ABS DWV pipe
- Designed for solvent-cement installation
- Suitable for drain, waste, and vent systems
- Non-pressure fitting
- Maximum operating temperature of 140°F
- Not intended for compressed air or gas service
- Not intended for pressure testing
- Manufactured from virgin ABS polymers
- Complies with ASTM D2661
- Certified to CSA B181.1
- Meets NSF Standard 14 requirements
Technical Specifications
| Product Type | ABS DWV P-Trap with Cleanout Plug |
|---|---|
| Material | ABS |
| Connection Type | Hub x Hub x Cleanout with Plug |
| Inlet Connection | Hub |
| Outlet Connection | Hub |
| Cleanout | Cleanout Opening with Removable Plug |
| Joint Method | Solvent Cement at Hub Connections |
| System Type | Drain, Waste, and Vent (DWV) |
| Pressure Service | Non-Pressure |
| Maximum Operating Temperature | 140°F |
| Primary Function | Create a Trap Seal While Providing Cleanout Access |
| Referenced Standards | ASTM D3965, ASTM D2661, CSA B181.1, NSF Standard 14 |
| Typical Applications | Sinks, Lavatories, Fixture Drains, Sanitary Drainage, Residential Plumbing, Commercial Plumbing, and Serviceable Trap Installations |
Connection Configuration
Hub Inlet & Outlet
The two hub connections form the trap inlet and outlet and accept compatible ABS DWV pipe for solvent-cement installation.
Cleanout with Plug
The cleanout opening includes a removable plug that provides access to the trap interior for cleaning, inspection, and maintenance.
P-Trap & Cleanout Design
The curved P-trap body retains a small amount of water after drainage, creating a trap seal between the fixture side and sanitary drainage system.
This water seal helps prevent sewer gases from traveling backward through the drainage line and entering occupied spaces.
The integrated cleanout opening provides an additional maintenance advantage by allowing access to the trap interior when debris or buildup needs to be removed.
Why Choose an ABS DWV P-Trap with Plug?
Trap Seal Protection
- Creates a water barrier in the drain line
- Helps block sewer gases
- Supports sanitary fixture drainage
- Designed for common fixture-drain layouts
- Maintains a permanent trap connection
Built-In Service Access
- Includes removable cleanout plug
- Provides direct trap access
- Useful for clearing debris
- Supports inspection and maintenance
- Can reduce the need to disassemble the piping system
Typical Applications
Fixture Drainage
- Sinks
- Lavatories
- Utility fixtures
- Residential fixture drains
- Commercial fixture drains
Serviceable DWV Installations
- Sanitary drain lines
- Waste piping
- Fixture branch piping
- Trap locations requiring cleanout access
- Residential and commercial plumbing
Standards & Compliance
- ASTM D3965: ABS material requirements for pipe extrusion and molded fittings
- ASTM D2661: Schedule 40 ABS drain, waste, and vent pipe and fittings
- CSA B181.1: ABS drain, waste, and vent pipe, fittings, and accessories
- NSF Standard 14: Plastic piping system components and related materials
Installation
Verify both nominal hub sizes and confirm that the P-trap configuration is appropriate for the intended fixture and DWV piping layout.
Position the fitting so the cleanout plug remains accessible after installation and adequate clearance is available for future removal and maintenance.
Cut all mating ABS pipe ends square and remove burrs. Clean and prepare the pipe and hub surfaces according to accepted ABS solvent-cement installation procedures.
Dry-fit the trap and adjoining piping before applying solvent cement to confirm proper orientation, trap positioning, and cleanout accessibility.
Apply compatible ABS solvent cement as required and fully seat each pipe into its corresponding hub while maintaining correct alignment.
Install and secure the cleanout plug according to the manufacturer's instructions. Allow completed solvent-cement joints to cure before placing the drainage system into service.

Our piping specialists can help review your trap size, fixture connection, cleanout access, drain layout, and ABS DWV compatibility before you order.
Email the GetPipe.com Team Visit Quick SupportFrequently Asked Questions
What is an ABS DWV P-trap with plug used for?
It is used to create a water seal in a fixture drainage line while also providing a removable cleanout opening for trap inspection and maintenance.
What does HUB x HUB x Cleanout with Plug mean?
It means the trap has two hub-style pipe connections plus a separate cleanout opening equipped with a removable plug.
How does the P-trap help block sewer gases?
The curved trap body retains water after drainage. This standing water forms a seal between the fixture and sanitary drainage system.
What is the purpose of the cleanout plug?
The plug closes the cleanout opening during normal operation and can be removed to provide access to the trap interior for cleaning or inspection.
Does the cleanout plug come with this fitting?
Yes. The supplied product description identifies this fitting as a P-Trap with Plug and specifies a cleanout opening with a removable plug.
Should the cleanout plug remain accessible?
Yes. The trap should be positioned so the cleanout can be reached for future servicing.
Does this fitting require solvent cement?
Yes. The hub inlet and outlet are intended for compatible ABS solvent-cement installation.
Is this fitting intended for pressure systems?
No. This fitting is intended for non-pressure drain, waste, and vent applications.
Can it be used for compressed air or gas?
No. The supplied product information states that ABS DWV fittings are not intended for transporting compressed air or gas.
Can this fitting be used for pressure testing?
No. The supplied product information states that ABS DWV fittings should not be used for pressure testing.
What is the maximum operating temperature?
The supplied product information specifies applications where operating temperatures do not exceed 140°F.
What should I verify before ordering?
Confirm both hub sizes, fixture-drain size, trap configuration, cleanout plug accessibility, mating ABS DWV pipe size, and intended non-pressure application.
Important Ordering & Installation Notes
- This listing is for an ABS DWV P-Trap with HUB x HUB x Cleanout with Plug configuration.
- Verify both nominal hub sizes before ordering.
- The fitting includes a removable cleanout plug.
- Confirm the trap size matches the intended fixture drain and ABS DWV piping.
- The curved trap body is designed to retain water and form a trap seal.
- Position the cleanout so it remains accessible after installation.
- Provide sufficient clearance for future cleanout plug removal.
- Both pipe connections are hub-style connections.
- Both hubs accept compatible ABS DWV pipe.
- Confirm trap orientation before installation.
- Dry-fit the complete assembly before applying solvent cement.
- This fitting is intended for non-pressure drain, waste, and vent applications.
- Do not use for transporting compressed air or gas.
- Do not use for pressure testing.
- Maximum operating temperature is 140°F.
- Use compatible ABS solvent cement for installation.
- Cut pipe square and remove burrs before assembly.
- Clean and prepare all mating surfaces before solvent-cement installation.
- Fully seat each ABS pipe into its corresponding hub.
- Install and secure the cleanout plug according to manufacturer recommendations.
- Maintain proper trap and drainage alignment while the solvent-cement joints set.
- Allow completed joints to cure according to the solvent cement manufacturer's recommendations before service.
- Protect the fitting from incompatible chemicals, fire-stopping materials, thread sealants, and other aggressive agents that may damage ABS compounds.
- Consult manufacturer documentation for complete dimensions and installation requirements.
- Follow applicable plumbing codes and manufacturer installation recommendations.