Midland Industries

Type DC Brass Cam & Groove Dust Cap Female Camlock

(No reviews yet) Write a Review
Availability:
Allow 1-2 Business Days to Ship
Weight:
0.00 LBS
*Images are for visual reference only.
  • Type DC Brass Cam & Groove Dust Cap Female Camlock
  • Midland Industries
$12.96 - $53.62

Represents the combined quantity sold of all the sizes under this product SKU.
Sold:
Frequently bought together:

Description

Type DC Brass Cam & Groove Dust Cap Female Camlock

Type DC Brass Cam & Groove Dust Caps feature a female camlock connection designed to cover and protect a compatible male cam & groove adapter when the connection is not in use.

The durable brass construction and quick-operating cam arms make the Type DC dust cap a practical protective accessory for compatible water transfer, agricultural, construction, industrial, petroleum-transfer, marine, and general fluid-handling systems.

Product Highlights

  • Type DC cam & groove dust cap configuration
  • Female camlock connection
  • Durable brass construction
  • Cam arms provide quick attachment and removal
  • Connects over a compatible male camlock adapter
  • Helps protect unused connections from dirt, debris, and contamination
  • Intended as a protective closure rather than a pressure-rated fitting

Technical Specifications

Product Type Cam & Groove Dust Cap
Camlock Type Type DC
Material Brass
Connection Female Camlock
Cam Arms Included
Mating Connection Compatible Male Cam & Groove Adapter
Primary Function Protective Closure for an Unused Male Camlock Connection
Pressure Service Not Intended for Pressure Applications

Construction Details

The Type DC fitting features a durable brass dust-cap body with a female cam & groove connection and operating cam arms.

The cap fits over a compatible male camlock adapter. Closing the cam arms secures the dust cap onto the adapter, helping cover the exposed connection while equipment, piping, tanks, or hose assemblies are disconnected.

Unlike Type B, C, and D couplers, a Type DC dust cap does not provide a secondary hose or threaded connection. Its purpose is to close and protect the male camlock end when the connection is not being used.

Connection Configuration

Female Camlock Dust Cap

The female cam & groove opening fits over a compatible male camlock adapter of the appropriate nominal size.

Cam Arms

The cam arms close around the male adapter and hold the dust cap in position. Opening the arms allows the cap to be quickly removed when the connection is needed.

How a Type DC Dust Cap Works

With the system safely depressurized and the male camlock adapter disconnected, open both cam arms on the Type DC dust cap.

Place the female dust cap over the compatible male cam & groove adapter and close both cam arms using normal hand pressure. This secures the cap over the exposed adapter.

When the connection is needed again, open the cam arms and remove the dust cap before attaching the appropriate female cam & groove coupler.

Camlock Connection Reference

Camlock Type Connection Mates With Cam Arms
Type DC Female Camlock Dust Cap Male Camlock Adapter Yes

Type DC vs. Type DP

Type DC

Female Camlock Dust Cap

Type DC fits over and protects a compatible male camlock adapter. The dust cap includes cam arms for securing it to the adapter.

Type DP

Male Camlock Dust Plug

Type DP inserts into and protects a compatible female camlock coupler. The cam arms on the female coupler secure the dust plug in position.

Common Applications

Hose, Pump & Tank Connections

  • Unused male camlock adapters
  • Transfer hose connections
  • Pump inlet and outlet connections
  • Tank and tote connections
  • Irrigation equipment
  • Portable transfer systems

Industrial & Fluid-Handling Systems

  • Industrial transfer equipment
  • Compatible petroleum-transfer systems
  • Construction and dewatering equipment
  • Agricultural fluid-transfer systems
  • Marine transfer equipment
  • General plant and maintenance applications

Installation & Selection Considerations

  • Confirm the male camlock adapter size before ordering the Type DC dust cap.
  • Use the dust cap only with a compatible male cam & groove adapter.
  • Inspect the cam arms, pins, gasket, cap body, and mating adapter before use.
  • Do not use a dust cap as a pressure-rated termination or substitute for a pressure-rated valve or closure.
  • Verify brass, gasket, temperature, media, and environmental compatibility for the application.
Willy knows his pipe sizes
Ask Willy: Need Help Selecting a Cam & Groove Fitting?

Our hose, fitting, and industrial product specialists can help review your camlock size, mating adapter, brass material requirements, gasket compatibility, connection configuration, and fluid-transfer application before you order.

Email the GetPipe.com Team Visit Quick Support

Frequently Asked Questions

What is a Type DC cam & groove fitting?

Type DC is a female cam & groove dust cap designed to fit over a compatible male camlock adapter.

What does a Type DC dust cap connect to?

A Type DC dust cap connects to a compatible male cam & groove adapter of the appropriate nominal size.

Does a Type DC dust cap have cam arms?

Yes. The female dust cap uses cam arms to secure the cap onto the male camlock adapter.

What is the purpose of a camlock dust cap?

A dust cap covers an unused male camlock connection and helps protect the exposed connection from dirt, debris, and contamination while disconnected.

What material is this Type DC dust cap made from?

This Type DC cam & groove dust cap features brass construction.

What is the difference between Type DC and Type DP?

Type DC is a female dust cap used on male camlock adapters. Type DP is a male dust plug used with female camlock couplers.

Is a Type DC dust cap a pressure-rated closure?

No. Cam & groove dust caps are intended as protective closures and should not be used as pressure-rated terminations.

Can a camlock dust cap be used for compressed air or steam?

No. Cam & groove couplings should not be used for compressed air or steam service.

Important Ordering & Installation Notes

  • Confirm the male camlock adapter size before ordering.
  • Type DC configuration is a female camlock dust cap.
  • Use only with a compatible male cam & groove adapter.
  • Do not use the dust cap as a pressure-rated system closure.
  • Verify brass, gasket, media, temperature, and application compatibility before use.
View AllClose

Reviews