Midland Industries

Type DC SS Cam & Groove Dust Cap Female Camlock

(No reviews yet) Write a Review
Availability:
Allow 1-2 Business Days to Ship
Weight:
0.00 LBS
*Images are for visual reference only.
  • Type DC SS Cam & Groove Dust Cap Female Camlock
  • Midland Industries
$18.07 - $277.79

Represents the combined quantity sold of all the sizes under this product SKU.
Sold:
Frequently bought together:

Description

Type DC SS Cam & Groove Dust Cap Female Camlock

Type DC Stainless Steel Cam & Groove Dust Caps feature a female camlock coupler connection designed to fit over and protect a compatible male cam & groove adapter when the connection is not in use.

The stainless steel construction provides corrosion resistance and durability for compatible water transfer, agricultural, construction, industrial, petroleum-transfer, chemical-processing, tank-transfer, marine, and general fluid-handling applications.

Product Highlights

  • Type DC cam & groove dust cap configuration
  • Female camlock connection
  • Stainless steel construction
  • Corrosion-resistant and durable design
  • Includes cam arms for quick attachment and removal
  • Fits over compatible male camlock adapters
  • Helps protect unused connections from dirt, debris, and contamination

Technical Specifications

Product Type Cam & Groove Dust Cap
Camlock Type Type DC
Material Stainless Steel
Connection Female Camlock
Cam Arms Included
Mating Connection Compatible Male Cam & Groove Adapter
Primary Function Protective Closure for an Unused Male Camlock Connection

Construction Details

The Type DC fitting features a durable stainless steel dust-cap body with a female cam & groove connection and operating cam arms.

The female opening fits over a compatible male camlock adapter. Closing the cam arms secures the dust cap onto the adapter and helps protect the exposed connection while the hose, piping, pump, tank, or other equipment is disconnected.

Unlike standard couplers that include a threaded or hose connection on the opposite end, a Type DC dust cap is designed specifically to cover and protect a male camlock adapter when it is not connected to another fitting.

Connection Configuration

Female Camlock Dust Cap

The female cam & groove opening fits over a compatible male camlock adapter. The connection should be matched by nominal camlock size.

Cam Arms

The cam arms close around the male adapter and hold the Type DC dust cap in position. Opening the arms allows the cap to be quickly removed when the connection is needed again.

How a Type DC Dust Cap Works

With the system safely depressurized and disconnected, open both cam arms on the Type DC dust cap.

Place the female dust cap over a compatible male cam & groove adapter and close both cam arms using normal hand pressure to secure the cap.

When the connection is needed again, open the cam arms and remove the dust cap before connecting the appropriate female cam & groove coupler.

Camlock Connection Reference

Camlock Type Connection Mates With Cam Arms
Type DC Female Camlock Dust Cap Male Camlock Adapter Included

Type DC vs. Type DP

Type DC

Female Camlock Dust Cap

Type DC fits over and protects a compatible male cam & groove adapter. The dust cap includes cam arms that secure it to the male adapter.

Type DP

Male Camlock Dust Plug

Type DP inserts into a compatible female cam & groove coupler. The cam arms on the female coupler secure the dust plug in position.

Common Applications

Hose, Pump & Tank Connections

  • Unused male camlock adapters
  • Water-transfer systems
  • Pump inlet and outlet connections
  • Tank and tote connections
  • Agricultural transfer equipment
  • Construction and dewatering systems

Corrosion-Resistant Fluid Handling

  • Compatible chemical-transfer equipment
  • Petroleum-transfer applications
  • Marine and washdown systems
  • Industrial process equipment
  • Plant maintenance systems
  • General fluid-transfer applications

Why Stainless Steel?

Stainless steel provides corrosion resistance and durability for demanding hose, piping, and fluid-transfer applications.

This construction can be especially useful where moisture, outdoor exposure, washdown, compatible chemicals, or corrosive operating environments make material resistance an important consideration.

Installation & Selection Considerations

  • Confirm the male camlock adapter size before ordering the Type DC dust cap.
  • Use with a compatible male cam & groove adapter.
  • Inspect the dust cap body, gasket, cam arms, pins, and mating adapter before use.
  • Do not connect or disconnect the fitting while the system is pressurized.
  • Verify stainless steel, gasket, media, temperature, and application compatibility before use.
Willy knows his pipe sizes
Ask Willy: Need Help Selecting a Cam & Groove Fitting?

Our hose, fitting, and industrial product specialists can help review your camlock connection, mating male adapter, stainless steel material requirements, gasket compatibility, connection configuration, and fluid-transfer application before you order.

Email the GetPipe.com Team Visit Quick Support

Frequently Asked Questions

What is a Type DC stainless steel cam & groove fitting?

Type DC is a female cam & groove dust cap designed to fit over a compatible male camlock adapter.

Does a Type DC dust cap have cam arms?

Yes. The Type DC female dust cap includes cam arms that secure it onto a compatible male camlock adapter.

What does the Type DC dust cap connect to?

The Type DC dust cap fits over a compatible male cam & groove adapter.

What is the purpose of a Type DC dust cap?

The dust cap covers an unused male camlock connection and helps protect the exposed adapter from dirt, debris, and contamination while disconnected.

What material is this Type DC dust cap made from?

This Type DC cam & groove dust cap features stainless steel construction.

What is the difference between Type DC and Type DP?

Type DC is a female dust cap used with male camlock adapters, while Type DP is a male dust plug used with female camlock couplers.

How do I select the correct Type DC dust cap?

Match the female camlock connection of the dust cap to the nominal size of the male cam & groove adapter you need to protect.

Should the system be depressurized before removing the dust cap?

Yes. Safely depressurize and drain the system as appropriate before opening the cam arms or removing the dust cap.

Important Ordering & Installation Notes

  • Confirm the mating male camlock connection before ordering.
  • Type DC configuration is a female camlock dust cap.
  • Use with a compatible male cam & groove adapter.
  • Inspect the gasket, cam arms, pins, body, and mating adapter before use.
  • Verify stainless steel, gasket, media, temperature, and application compatibility before use.
View AllClose

Reviews