ASC

AWWA Indicator Post, Vertical

(No reviews yet) Write a Review
SKU:
4349003400
Availability:
Usually Ships Same Day
Weight:
214.14 LBS
*Images are for visual reference only.
  • AWWA Indicator Post, Vertical
  • AWWA Indicator Post, Vertical Data Sheet
$1,042.08

Represents the combined quantity sold of all the sizes under this product SKU.
Sold:
Frequently bought together:

Description

UL/FM AWWA Vertical Indicator Post – Adjustable 36" to 72"

UL/FM AWWA Vertical Indicator Post is designed for operation and visual indication of compatible non-rising-stem gate valves used in fire-protection and water-service systems. The post provides above-ground access to the valve operating mechanism while allowing personnel to visually confirm whether the connected valve is in the open or closed position.

Designed with an adjustable height range from 36" to 72", this vertical indicator post features a cast iron body, stainless steel operating nut, fusion-bonded epoxy coating, and UL Listed / FM Approved construction for compatible fire-protection and water-system installations.

Product Highlights

  • Vertical AWWA indicator post
  • Adjustable from 36" to 72"
  • Cast iron body
  • Stainless steel operating nut
  • Fusion-bonded epoxy coating
  • Provides above-ground operation of compatible buried gate valves
  • Provides visible valve-position indication
  • Designed for compatible non-rising-stem gate valves
  • UL Listed
  • FM Approved
  • Suitable for compatible fire-protection and water-service applications

Technical Specifications

Product Type Vertical Indicator Post
Application Operation & Position Indication for Compatible Gate Valves
Configuration Vertical
Adjustable Height 36" to 72"
Body Material Cast Iron
Operating Nut Material Stainless Steel
Coating Fusion-Bonded Epoxy
Valve Compatibility Compatible Non-Rising-Stem Gate Valves
Position Indication Open / Closed Visual Indication
Listing UL Listed
Approval FM Approved

What Is a Vertical Indicator Post?

A vertical indicator post provides an above-ground operating point for a compatible gate valve installed below grade or otherwise inaccessible for direct operation. The post connects mechanically to the valve stem or operating mechanism so the buried valve can be opened or closed from the surface.

The indicator post also provides a visible indication of valve position, allowing personnel to confirm whether the connected valve is open or closed without accessing the buried valve directly.

Vertical Indicator Post vs. Direct Valve Access

Vertical Indicator Post

  • Provides above-ground valve operation
  • Provides visible valve-position indication
  • Useful for buried or difficult-to-access valves
  • Adjustable installation height
  • Common in fire-protection systems

Direct Valve Access

  • Requires physical access to the valve operator
  • May require valve box, vault, or mechanical-room access
  • No separate above-ground position indicator
  • May be suitable for exposed or easily accessible valves
  • Access requirements depend on installation conditions

Adjustable 36" to 72" Height

The vertical indicator post is adjustable from 36 inches to 72 inches, allowing the installed height to be adapted to site conditions, burial depth, finished grade, and the location of the connected valve.

Confirm the required extension, valve depth, and finished installation height before ordering and installation.

Cast Iron Body

The cast iron body provides durable structural support for the indicator-post operating mechanism and enclosure. This construction is commonly used for fire-protection and water-system indicator posts because of its strength and long service history.

Inspect the body and protective coating before installation and repair any installation damage according to manufacturer recommendations.

Fusion-Bonded Epoxy Coating

The indicator post features a fusion-bonded epoxy coating to provide corrosion protection for the cast iron body and help extend service life in outdoor and utility environments.

Review manufacturer documentation when coating requirements, repair procedures, or project-specific corrosion-protection requirements must be verified.

Stainless Steel Operating Nut

The indicator post uses a stainless steel operating nut to provide a durable operating interface for opening and closing the connected valve.

Use the appropriate operating wrench or approved tool and follow manufacturer instructions for valve operation, adjustment, and maintenance.

Common Applications

Fire-Protection Systems

  • Fire-sprinkler water supplies
  • Fire-service mains
  • Private fire-protection piping
  • Buried control-valve installations
  • Systems requiring visible valve-position indication

Water & Utility Systems

  • Buried gate-valve installations
  • Utility water systems
  • Municipal water-service applications
  • Valve locations requiring above-ground access
  • Compatible non-rising-stem gate valves

UL Listed & FM Approved

This vertical indicator post is identified as UL Listed and FM Approved. These listings are commonly required on fire-protection equipment where system components must meet recognized third-party performance and safety requirements.

Confirm that the exact indicator-post configuration, connected valve, installation method, and system design satisfy the project specifications and applicable fire-protection requirements.

Installation Guidance

  • Confirm compatibility with the intended gate valve before ordering.
  • Verify that the connected valve uses a compatible non-rising-stem operating arrangement.
  • Confirm the required installed height and adjustment range.
  • Verify valve burial depth and finished-grade elevation before installation.
  • Inspect the cast iron body, operating nut, internal mechanism, coating, and mounting components before installation.
  • Position the indicator post vertically over the valve operating mechanism.
  • Align the operating connection carefully to prevent binding.
  • Adjust the post height according to site conditions and manufacturer instructions.
  • Confirm that the OPEN and SHUT indication corresponds correctly with actual valve position.
  • Operate the connected valve fully open and fully closed after installation to verify proper function.
  • Do not force the operating mechanism if binding or resistance is encountered.
  • Protect the indicator post from vehicle impact or other site hazards where required.
  • Maintain clear access around the operating nut and visual indicators.
  • Inspect the post periodically for coating damage, corrosion, mechanical damage, or operating problems.
  • Installation should be completed by qualified personnel familiar with fire-protection and water-system indicator posts.
Willy knows his pipe sizes
Ask Willy: Need help confirming this AWWA Vertical Indicator Post?

Use the supplied ASC product data sheet to confirm the adjustable height range, gate-valve compatibility, installation requirements, UL listing, FM approval, and other product-specific information before ordering.

Need Help Selecting an AWWA Vertical Indicator Post?

Need help confirming indicator-post height, valve compatibility, operating requirements, fire-protection application, or installation conditions? The GetPipe.com Team can help you verify the right indicator post before ordering.

Frequently Asked Questions

What is a vertical indicator post?

A vertical indicator post provides above-ground operation and visible open-or-closed indication for a compatible gate valve installed below grade or in another difficult-to-access location.

What is the adjustable height range?

The indicator post is adjustable from 36 inches to 72 inches.

What material is the body?

The indicator post uses a cast iron body.

What material is the operating nut?

The operating nut is stainless steel.

What type of coating does the post have?

The indicator post has a fusion-bonded epoxy coating for corrosion protection.

What type of valve does an indicator post operate?

A vertical indicator post is designed to operate compatible non-rising-stem gate valves. Confirm exact valve compatibility before ordering.

What does the indicator post show?

The post provides visible indication of whether the connected valve is in the open or closed position.

Why use an indicator post instead of accessing the valve directly?

An indicator post allows personnel to operate and visually confirm the position of a buried or otherwise inaccessible valve from above grade.

Is this indicator post UL Listed?

Yes. The supplied product information identifies the vertical indicator post as UL Listed.

Is this indicator post FM Approved?

Yes. The supplied product information identifies the vertical indicator post as FM Approved.

Where are vertical indicator posts commonly used?

Typical applications include fire-sprinkler water supplies, fire-service mains, buried water-system gate valves, utility installations, and other systems requiring above-ground valve operation and position indication.

How do I determine the correct installed height?

Determine the valve burial depth, finished-grade elevation, required operating height, and manufacturer adjustment requirements before installation. This model provides an adjustable range from 36 inches to 72 inches.

Does the indicator need to be adjusted after installation?

Yes. The indicator mechanism should be adjusted so the OPEN and SHUT indication accurately matches the actual position of the connected valve.

Can this post be used with any gate valve?

No. Confirm that the gate valve and operating mechanism are compatible with the indicator post before ordering or installation.

Should I review the product data sheet before ordering?

Yes. Review the manufacturer product data sheet for dimensions, adjustment range, valve compatibility, installation requirements, UL listing, FM approval, and other product-specific information.

Important Ordering Notes

  • Confirm the required indicator-post configuration before ordering.
  • This product is a vertical indicator post.
  • Adjustable height range: 36" to 72".
  • Body material: cast iron.
  • Operating nut: stainless steel.
  • Fusion-bonded epoxy coating.
  • UL Listed.
  • FM Approved.
  • Confirm compatibility with the intended non-rising-stem gate valve.
  • Verify valve burial depth and required finished installation height.
  • Confirm the operating connection and stem arrangement before installation.
  • Adjust OPEN and SHUT indication to match actual valve position.
  • Maintain clear access to the operating nut and visual indicators.
  • Review manufacturer technical information when project-specific dimensions, listings, or approvals are required.
  • Installation should be completed by qualified personnel.
View AllClose