ASC
AWWA Indicator Post, Wall
- SKU:
- 4349003410
- Availability:
- Usually Ships Same Day
- Weight:
- 91.00 LBS
Description
UL/FM AWWA Wall Indicator Post – Series 25WP
Series 25WP AWWA Wall Indicator Post is designed to provide remote operation and visible position indication for compatible non-rising-stem gate valves used in fire-protection and water-service systems. The wall-mounted configuration is ideal where the connected valve is located behind a wall, inside a building, or in another location where direct valve access is limited.
The Series 25WP features a cast iron body, stainless steel operating nut, fusion-bonded epoxy coating, and UL Listed / FM Approved construction. SCI® branding provides full product traceability for projects requiring documented valve and fire-protection components.
Product Highlights
- AWWA wall indicator post
- Series 25WP
- Wall-mounted configuration
- Cast iron body
- Stainless steel operating nut
- Fusion-bonded epoxy coating
- Provides remote operation of compatible non-rising-stem gate valves
- Provides visible valve-position indication
- UL Listed
- FM Approved
- SCI® Brand for full traceability
- Suitable for compatible fire-protection and water-service applications
Technical Specifications
| Product Type | Wall Indicator Post |
|---|---|
| Series | 25WP |
| Configuration | Wall Mounted |
| Application | Remote Operation & Position Indication for Compatible Gate Valves |
| Body Material | Cast Iron |
| Operating Nut Material | Stainless Steel |
| Coating | Fusion-Bonded Epoxy |
| Valve Compatibility | Compatible Non-Rising-Stem Gate Valves |
| Position Indication | Open / Closed Visual Indication |
| Listing | UL Listed |
| Approval | FM Approved |
| Brand | SCI® |
| Traceability | SCI® Brand for Full Traceability |
What Is a Wall Indicator Post?
A wall indicator post provides a remote operating point for a compatible gate valve located on the opposite side of a wall or in another location where direct access to the valve operator is limited.
The indicator post connects mechanically to the valve operating mechanism and provides visible indication of whether the connected valve is open or closed.
Wall Indicator Post vs. Vertical Indicator Post
Wall Indicator Post – Series 25WP
- Designed for wall-mounted installations
- Provides remote valve operation through a wall
- Provides visible valve-position indication
- Useful where the valve is inside or behind a structure
- Compact alternative to a vertical post where above-ground mounting is not appropriate
Vertical Indicator Post
- Designed for vertical above-ground installations
- Common with buried gate valves
- Provides above-ground valve operation
- Provides visible open / closed indication
- Typically installed over the connected valve
Cast Iron Body
The Series 25WP uses a cast iron body to provide durable structural support for the indicator-post operating mechanism and enclosure.
Inspect the body and protective coating before installation and follow manufacturer recommendations if coating repairs or other maintenance are required.
Fusion-Bonded Epoxy Coating
The indicator post features a fusion-bonded epoxy coating to provide corrosion protection for the cast iron body and help support long service life in compatible fire-protection and water-system environments.
Review manufacturer documentation when project-specific coating, repair, or corrosion-protection requirements must be verified.
Stainless Steel Operating Nut
The Series 25WP uses a stainless steel operating nut to provide a durable operating interface for opening and closing the connected valve.
Use the appropriate operating wrench or approved tool and follow manufacturer instructions for operation, adjustment, and maintenance.
Common Applications
Fire-Protection Systems
- Fire-sprinkler water supplies
- Fire-service mains
- Private fire-protection piping
- Control valves located behind walls
- Systems requiring visible valve-position indication
Water & Utility Systems
- Remote gate-valve operation
- Building water-service systems
- Utility water installations
- Valves located in inaccessible spaces
- Compatible non-rising-stem gate valves
UL Listed & FM Approved
The Series 25WP is identified as UL Listed and FM Approved. These listings are commonly specified for fire-protection components where recognized third-party listings and approvals are required.
Confirm that the exact indicator-post configuration, connected valve, installation arrangement, and overall system design satisfy project specifications and applicable fire-protection requirements.
SCI® Brand Traceability
The Series 25WP is supplied under the SCI® Brand for full traceability. Product traceability can be important on commercial, municipal, fire-protection, and engineered projects where product identification and documentation must be maintained.
Retain applicable product documentation and manufacturer information when required by the project specifications.
Installation Guidance
- Confirm compatibility with the intended gate valve before ordering.
- Verify that the connected valve uses a compatible non-rising-stem operating arrangement.
- Confirm the required wall location and mounting configuration.
- Verify wall thickness, valve location, and operating-shaft alignment before installation.
- Inspect the cast iron body, operating nut, internal mechanism, coating, and mounting components before installation.
- Align the indicator-post operating mechanism carefully with the connected valve.
- Mount the indicator post securely to a suitable wall or structural surface.
- Confirm that the connecting operating mechanism is free from binding.
- Adjust the OPEN and SHUT indication to correspond correctly with actual valve position.
- Operate the connected valve fully open and fully closed after installation to verify proper function.
- Do not force the operating mechanism if excessive resistance is encountered.
- Maintain clear access around the operating nut and visual indicators.
- Inspect the post periodically for coating damage, corrosion, mechanical damage, or operating problems.
- Confirm that installation complies with applicable fire-protection requirements and project specifications.
- Installation should be completed by qualified personnel familiar with fire-protection and water-system indicator posts.

Use the supplied ASC Series 25WP product data sheet to confirm wall-mounting requirements, gate-valve compatibility, operating arrangement, dimensions, UL listing, FM approval, and other product-specific information before ordering.
Need Help Selecting an AWWA Wall Indicator Post?
Need help confirming wall-post configuration, valve compatibility, operating requirements, fire-protection application, mounting conditions, or installation requirements? The GetPipe.com Team can help you verify the right indicator post before ordering.
Frequently Asked Questions
What is the Series 25WP?
The Series 25WP is a wall-mounted AWWA indicator post designed to provide remote operation and visible position indication for a compatible gate valve.
What is a wall indicator post used for?
A wall indicator post allows a compatible gate valve to be operated remotely through a wall while providing visible indication of whether the valve is open or closed.
What material is the body?
The Series 25WP uses a cast iron body.
What material is the operating nut?
The operating nut is stainless steel.
What type of coating does the post have?
The Series 25WP has a fusion-bonded epoxy coating for corrosion protection.
What type of valve does a wall indicator post operate?
A wall indicator post is designed for use with compatible non-rising-stem gate valves. Confirm exact valve compatibility before ordering.
What does the indicator post show?
The post provides visible indication of whether the connected valve is in the open or closed position.
What is the difference between a wall post and a vertical indicator post?
A wall indicator post is mounted to a wall and operates a valve remotely through the wall. A vertical indicator post is generally installed above a buried valve and extends vertically above grade.
Is the Series 25WP UL Listed?
Yes. The supplied product information identifies the Series 25WP as UL Listed.
Is the Series 25WP FM Approved?
Yes. The supplied product information identifies the Series 25WP as FM Approved.
What does SCI® Brand for full traceability mean?
The product is supplied under the SCI® Brand, providing product identification and traceability for applications where documentation of installed components is important.
Where are wall indicator posts commonly used?
Typical applications include fire-sprinkler systems, fire-service mains, commercial buildings, utility water systems, and other installations where a gate valve must be operated and monitored remotely through a wall.
Does the wall thickness matter?
Yes. Wall thickness, valve location, operating-shaft alignment, and installation geometry should be confirmed before installation using the manufacturer product data.
Does the indicator need to be adjusted after installation?
Yes. The indicator mechanism should be adjusted so the OPEN and SHUT indication accurately corresponds with the actual position of the connected valve.
Can this post be used with any gate valve?
No. Confirm that the connected valve and operating mechanism are compatible with the Series 25WP before ordering or installation.
Should I review the product data sheet before ordering?
Yes. Review the Series 25WP product data sheet for dimensions, valve compatibility, installation requirements, UL listing, FM approval, and other product-specific information.
Important Ordering Notes
- Confirm the required wall-indicator-post configuration before ordering.
- This product is the Series 25WP wall indicator post.
- Body material: cast iron.
- Operating nut: stainless steel.
- Fusion-bonded epoxy coating.
- UL Listed.
- FM Approved.
- SCI® Brand for full traceability.
- Confirm compatibility with the intended non-rising-stem gate valve.
- Verify wall thickness, valve position, operating-shaft alignment, and mounting requirements.
- Confirm the operating connection and stem arrangement before installation.
- Adjust OPEN and SHUT indication to match actual valve position.
- Maintain clear access to the operating nut and visual indicators.
- Review manufacturer technical information when project-specific dimensions, listings, approvals, or mounting requirements are required.