Description
ABS DWV Sanitary Tee (HUB x HUB x HUB)
ABS DWV Sanitary Tees provide a branch connection in non-pressure drain, waste, and vent systems while maintaining a smooth transition into the main piping run.
Featuring three hub connections, this fitting is designed to connect compatible ABS DWV pipe in sanitary drainage, waste, vent, sewer, and general drainage applications. The branch enters the main run through a curved sanitary pattern to support proper drainage flow and venting. Manufactured for ABS DWV service, it conforms to ASTM D2661, CSA B181.1, and NSF Standard 14.
Product Highlights
- ABS DWV sanitary tee
- Hub x Hub x Hub connection configuration
- Three hub connections for compatible ABS DWV pipe
- Provides a branch connection into the main piping run
- Sanitary-pattern branch transition
- Designed for solvent-cement installation
- Suitable for drain, waste, and vent systems
- Suitable for sewer and general drainage applications
- Non-pressure fitting
- Maximum operating temperature of 140°F
- Not intended for compressed air or gas service
- Not intended for testing
- Manufactured from virgin ABS polymers and blends suitable for molded fittings
- Conforms to ASTM D2661
- Conforms to CSA B181.1
- Meets NSF Standard 14 requirements
Technical Specifications
| Product Type | ABS DWV Sanitary Tee |
|---|---|
| Material | ABS |
| Connection Type | Hub x Hub x Hub |
| Number of Connections | 3 |
| Joint Method | Solvent Cement |
| System Type | Drain, Waste, and Vent (DWV) |
| Pressure Service | Non-Pressure |
| Maximum Operating Temperature | 140°F |
| Primary Function | Provide a Sanitary Branch Connection into an ABS DWV Piping Run |
| Referenced Standards | ASTM D3965, ASTM D2661, CSA B181.1, NSF Standard 14 |
| Typical Applications | Sanitary Drainage, Waste Lines, Vent Systems, Sewer, and General Drainage |
Connection Configuration
Main Run Hubs
Two hub connections form the primary piping run and accept compatible ABS DWV pipe for solvent-cement installation.
Branch Hub
The third hub forms the branch connection and accepts compatible ABS DWV pipe entering the sanitary tee.
Sanitary Tee Design
The sanitary tee uses a curved branch transition rather than an abrupt intersection, helping guide flow into the main run in drainage and vent applications.
This configuration is commonly used where a branch line connects to a vertical or otherwise code-approved DWV piping arrangement.
All three hub connections are designed for compatible ABS solvent-cement joining and non-pressure drainage service.
Why Choose an ABS DWV Sanitary Tee?
Branch Connection
- Provides a dedicated branch connection
- Three hub connections
- Sanitary-pattern transition
- Compact one-piece fitting
- Useful in drainage and vent piping layouts
ABS DWV Benefits
- Lightweight construction
- Easy handling and installation
- Suitable for non-pressure drainage systems
- Compatible with ABS DWV piping systems
- Designed for long-term sanitary drainage service
Typical Applications
Drainage Systems
- Sanitary drain lines
- Waste piping
- General building drainage
- Sewer piping
- ABS DWV branch connections
Vent Systems
- Fixture vent piping
- Branch vent connections
- Vertical DWV layouts
- Residential plumbing
- Commercial plumbing systems
Standards & Compliance
- ASTM D3965: Covers virgin ABS polymers and blends suitable for pipe extrusion and molding of fittings
- ASTM D2661: Covers Schedule 40 ABS drain, waste, and vent pipe and fittings
- CSA B181.1: Covers ABS drain, waste, and vent pipe, fittings, and related accessories
- NSF Standard 14: Plastic piping system components and related materials
Installation
Verify the nominal sizes of all three hub connections before installation and confirm compatibility with the intended ABS DWV piping layout.
Cut all mating pipe ends square and remove burrs. Clean and prepare the pipe and hub surfaces according to accepted ABS solvent-cement installation procedures.
Dry-fit the assembly first to confirm branch orientation before applying solvent cement.
Apply compatible ABS solvent cement as required and fully seat each pipe into its corresponding hub while maintaining proper alignment.
Allow completed joints to cure according to the solvent cement manufacturer's recommendations before placing the drainage or vent system into service.

Our piping specialists can help review your run size, branch size, piping orientation, and ABS DWV compatibility before you order.
Email the GetPipe.com Team Visit Quick SupportFrequently Asked Questions
What is an ABS DWV sanitary tee used for?
It is used to create a branch connection within a non-pressure ABS drain, waste, or vent piping system.
What does HUB x HUB x HUB mean?
It means all three connections are hubs designed to accept compatible ABS DWV pipe for solvent-cement installation.
How many connections does this fitting have?
It has three hub connections: two for the main run and one for the branch.
What makes this a sanitary tee?
The branch connection uses a curved sanitary pattern intended to guide flow into the main piping run more smoothly than an abrupt square intersection.
Does this fitting require solvent cement?
Yes. All three hub connections are intended for compatible ABS solvent-cement installation.
Is this fitting intended for pressure systems?
No. The supplied product information identifies ABS DWV fittings for non-pressure applications.
Can it be used for compressed air or gas?
No. The supplied product information states that LESSO America ABS DWV fittings are not for the distribution or transportation of compressed air or gas.
Can this fitting be used for testing?
No. The supplied product information states that LESSO America ABS DWV fittings are not intended for test use.
What is the maximum operating temperature?
The supplied product information specifies a maximum operating temperature of 140°F.
What should I verify before ordering?
Confirm all three hub sizes, the intended branch orientation, mating ABS DWV pipe sizes, and the intended non-pressure drainage or vent application.
Important Ordering & Installation Notes
- This listing is for an ABS DWV Sanitary Tee with HUB x HUB x HUB connections.
- Verify all three nominal connection sizes before ordering.
- Two hubs form the main piping run.
- The third hub forms the branch connection.
- Confirm branch orientation before installation.
- Dry-fit the complete assembly before applying solvent cement.
- This fitting is intended for non-pressure DWV, sewer, and general drainage applications.
- Do not use for transporting compressed air or gas.
- Do not use for testing.
- Maximum operating temperature is 140°F.
- Use compatible ABS solvent cement for installation.
- Cut pipe square and remove burrs before assembly.
- Clean and prepare all mating surfaces before solvent-cement installation.
- Fully seat each ABS pipe into its corresponding hub.
- Maintain proper branch and run alignment during installation.
- Allow completed joints to cure according to the solvent cement manufacturer's recommendations before service.
- Protect the system from chemical agents, fire-stopping materials, thread sealants, and other aggressive materials not compatible with ABS compounds.
- Consult manufacturer documentation for complete dimensions and installation requirements.
- Follow applicable plumbing codes and manufacturer installation recommendations.