Lesso America
PVC DWV Sanitary Tee (HUB x HUB x HUB)
- SKU:
- LP400
- Availability:
- Usually Ships Same Day
- Weight:
- 0.00 LBS
Description
PVC DWV Sanitary Tee (HUB x HUB x HUB)
PVC DWV Sanitary Tees provide a dependable branch connection for non-pressure drain, waste, and vent piping systems.
Featuring hub connections on all three openings, this fitting accepts compatible PVC DWV pipe for permanent solvent-weld installation. The sanitary tee configuration is designed to introduce a branch into the main piping run while helping maintain proper flow through residential, commercial, and industrial drainage systems.
Product Highlights
- PVC DWV sanitary tee fitting
- Hub x Hub x Hub connection configuration
- Creates a branch connection in DWV piping
- Designed for drain, waste, and vent systems
- All three hubs accept compatible PVC DWV pipe
- Solvent-weld installation
- Smooth internal surfaces support efficient drainage flow
- Durable corrosion-resistant PVC construction
- Lightweight and easy to install
- Suitable for residential, commercial, and industrial DWV systems
- Designed for non-pressure applications
Technical Specifications
| Product Type | DWV Sanitary Tee |
|---|---|
| Material | PVC |
| Connection Type | Hub x Hub x Hub |
| Joint Method | Solvent Weld |
| System Type | Drain, Waste & Vent (DWV) |
| Pressure Service | Non-Pressure |
| Primary Function | Branch Connection in DWV Piping |
| Referenced Standards | ASTM D2665, ASTM D1784, CSA B181.2, and Applicable NSF/ANSI Standards |
| Typical Applications | Residential, Commercial, and Industrial DWV Systems |
Connection Configuration
Run Inlet
The first hub accepts compatible PVC DWV pipe as part of the main piping run.
Branch Connection
The branch hub provides the additional connection used to introduce another DWV line into the fitting.
Run Outlet
The opposite hub continues the main piping run with another compatible section of PVC DWV pipe.
Construction Details
The sanitary tee is manufactured from durable PVC for resistance to corrosion, chemicals, moisture, and long-term wear in compatible drain, waste, and vent systems.
Hub connections on all three openings are designed for solvent-cement joining to compatible PVC pipe, creating secure permanent joints when properly installed.
The internal geometry provides a defined branch transition while smooth interior surfaces help maintain drainage flow and reduce unnecessary restriction.
Why Choose a Sanitary Tee?
DWV Branch Connection
- Adds a branch to the main piping run
- Connects three compatible PVC DWV lines
- Useful in drainage and vent layouts
- Suitable for new installations and repairs
- Provides permanent solvent-weld connections
PVC DWV Construction
- Corrosion-resistant material
- Lightweight construction
- Resistant to many common plumbing chemicals
- Designed for solvent-weld assembly
- Suitable for long-term non-pressure service
Typical Applications
Residential DWV Systems
- Fixture drain connections
- Waste piping branches
- Vent piping layouts
- Building drainage systems
- General residential plumbing
Commercial & Industrial DWV
- Commercial drainage systems
- Building waste piping
- Branch drainage connections
- Repair and retrofit work
- Compatible industrial DWV systems
Solvent-Weld Installation
Cut compatible PVC DWV pipe square and remove burrs before installation. Clean and prepare the pipe ends and fitting hubs according to accepted PVC solvent-weld procedures.
Apply compatible PVC primer and solvent cement where required, fully seat each pipe into the appropriate hub, and confirm the branch orientation before the cement begins to set.
Allow all completed joints to cure according to the solvent-cement manufacturer's recommendations before placing the system into normal service.

Our plumbing specialists can help review your pipe size, branch layout, DWV application, and solvent-weld installation requirements before you order.
Email the GetPipe.com Team Visit Quick SupportFrequently Asked Questions
What is a PVC DWV sanitary tee?
A sanitary tee is a three-opening fitting used to create a branch connection in compatible drain, waste, and vent piping systems.
What does HUB x HUB x HUB mean?
It means all three openings are hub or socket connections designed to accept compatible PVC DWV pipe.
What is the primary purpose of this fitting?
Its primary purpose is to connect a branch line into a compatible main DWV piping run.
How is the sanitary tee installed?
All three hub connections are installed using compatible PVC solvent-weld procedures.
Is this fitting intended for pressure piping?
No. This fitting is intended for non-pressure drain, waste, and vent systems.
What material is the fitting made from?
The sanitary tee is manufactured from durable, corrosion-resistant PVC.
Can this fitting be used for vent piping?
Yes. It can be used in compatible DWV vent layouts where the fitting configuration is appropriate for the installation.
Do I need PVC primer and solvent cement?
Use compatible PVC primer and solvent cement as required by the manufacturer, solvent-cement instructions, and applicable plumbing requirements.
What standards are referenced for this fitting?
The supplied product information references ASTM D2665, ASTM D1784, CSA B181.2, and applicable NSF/ANSI standards.
What should I verify before ordering?
Confirm the nominal pipe size, Hub x Hub x Hub configuration, branch requirements, and compatibility with the intended PVC DWV system.
Important Ordering & Installation Notes
- This listing is for a PVC DWV Sanitary Tee with HUB x HUB x HUB connections.
- Verify the required nominal pipe size before ordering.
- All three hubs accept compatible PVC DWV pipe.
- The fitting is designed to create a branch connection in a DWV piping system.
- Designed for non-pressure drain, waste, and vent applications.
- Use compatible PVC primer and solvent cement where required.
- Cut pipe square before installation.
- Remove burrs and clean all mating surfaces before solvent welding.
- Fully seat pipe into each hub during assembly.
- Confirm branch orientation before the solvent cement begins to set.
- Allow completed joints to cure according to the cement manufacturer's recommendations.
- Do not use this fitting for pressure applications.
- Verify the sanitary tee configuration is appropriate for the specific DWV layout.
- Check completed joints for proper assembly before normal use.
- Follow applicable plumbing codes and manufacturer installation requirements.