Spears

PVC DWV 90 Degree Sanitary Tee w/ 2" R & L Side Inlets

(No reviews yet) Write a Review
SKU:
P418
Availability:
Usually Ships Same Day
Weight:
0.00 LBS
*Images are for visual reference only.
  • PVC DWV 90 Degree Sanitary Tee w/ 2" R and L Side Inlets (H x H x H x H)
  • Spears Logo
  • PVC DWV 90 Degree Sanitary Tee w/ 2" R and L Side Inlets (H x H x H x H)
$34.18 - $148.14

Represents the combined quantity sold of all the sizes under this product SKU.
Sold:
Frequently bought together:

Description

PVC DWV 90 Degree Sanitary Tee w/ 2" R & L Side Inlets

Spears® PVC DWV 90 Degree Sanitary Tee w/ 2" Right & Left Side Inlets combines a sanitary tee configuration with two additional 2" side inlets positioned on the right and left sides of the fitting. This multi-connection design allows several compatible PVC drain, waste, and vent lines to enter a common fitting location.

The integrated right and left 2" side inlets provide additional branch-entry points beyond the primary sanitary tee connections. This configuration can simplify DWV layouts where multiple drainage or vent connections need to converge within a limited area while maintaining a single molded fitting assembly.

Product Highlights

  • PVC construction
  • 90-degree sanitary tee
  • Two 2" side inlets
  • Right and left inlet locations
  • Multiple DWV connection points
  • Combines sanitary and side connections
  • Reduces the need for separate nearby branch fittings
  • Designed for compatible PVC drain, waste, and vent systems

Technical Specifications

Product Type DWV Sanitary Tee with Side Inlets
Manufacturer Spears® Manufacturing Company
Material PVC
System Type Drain, Waste & Vent (DWV)
Fitting Configuration 90 Degree Sanitary Tee
Side Inlet Size 2"
Side Inlet Locations Right & Left
Branch Arrangement Sanitary Tee Branch with Dual Side Inlets
Connection Sizes Dependent on Selected Product Variation
Application Compatible PVC DWV Piping Systems
Primary Function Combine Multiple DWV Connections at a Sanitary Tee Location

90-Degree Sanitary Tee Configuration

The 90-degree sanitary tee configuration provides a primary branch connection into the main DWV piping while incorporating the curved directional transition associated with a sanitary tee. This allows the primary branch to enter the common drainage arrangement within one molded fitting.

The sanitary tee portion should be positioned according to the intended direction of the main piping and primary branch connection. Planning this orientation before assembly helps keep the fitting aligned with the surrounding DWV layout and the additional side branches.

Right & Left 2" Side Inlets

Two additional 2" side inlets are incorporated into the fitting, with one located on the right and the other on the left. These opposing inlet locations provide dedicated connection points for compatible 2" DWV lines entering from both sides of the sanitary tee.

The dual-side arrangement is especially useful when the piping layout requires connections approaching from opposite directions. Both 2" inlet locations should be considered during rough-in so the adjoining branch lines can reach the fitting without unnecessary offsets.

Multi-Connection DWV Layout

This fitting combines the main sanitary tee arrangement and two side-entry connections into one component. Consolidating these connection points can reduce the number of individual fittings required where several DWV lines converge in the same section of the piping system.

Because several lines meet at one fitting, available space should be evaluated for every adjoining pipe rather than only the main run. Nearby framing, other fittings, and pipe routing can affect how easily each connection can be assembled and supported.

Side-Inlet Orientation

The specified right and left inlet positions are important when matching this sanitary tee to the planned piping arrangement. Both side connections need to face the corresponding 2" branch lines while the primary sanitary tee remains oriented with the main DWV route.

Dry-positioning the fitting with the surrounding piping helps establish all connection directions before permanent assembly. This is particularly useful with a multi-inlet fitting because rotating the body changes the position of several branch connections at the same time.

Installation & Selection Considerations

  • Confirm the main fitting size.
  • Verify both 2" branch connections.
  • Identify the right and left inlet locations.
  • Check clearance for every adjoining pipe.
  • Match the sanitary tee orientation to the layout.
Willy knows his pipe sizes
Ask Willy: Need Help Selecting a PVC DWV 90 Degree Sanitary Tee with 2" R & L Side Inlets?

Our PVC DWV fitting specialists can help review the sanitary tee size, two 2" side connections, right and left inlet orientation, adjoining branch piping, main DWV layout, and available installation clearance to help confirm the correct fitting before you order.

Frequently Asked Questions

What type of fitting is this?

It is a PVC DWV 90-degree sanitary tee with two additional 2" side inlets.

How many side inlets are included?

The fitting has two side inlets in addition to its primary sanitary tee connections.

What size are the side inlets?

Both additional side inlets are identified as 2" connections.

Where are the 2" side inlets positioned?

One 2" inlet is located on the right side and the other is located on the left side of the fitting.

Why use a sanitary tee with two side inlets?

The configuration allows multiple compatible DWV lines to converge at one fitting location instead of requiring several separate branch fittings nearby.

Does the side-inlet orientation matter?

Yes. The right and left inlets should correspond with the direction of the adjoining 2" branch piping in the planned DWV layout.

Should this fitting be positioned before permanent assembly?

Yes. Dry-positioning helps establish the sanitary tee direction and both side-inlet locations before the connections are permanently completed.

What should I confirm before ordering?

Confirm the primary fitting size, two 2" side connections, right and left inlet arrangement, sanitary tee orientation, and available space for the adjoining piping.

Important Ordering & Installation Notes

  • Mark both 2" branch locations.
  • Dry-position the complete fitting first.
  • Keep the main piping properly aligned.
  • Seat each connection evenly during assembly.
  • Support the adjoining branch piping independently.
View AllClose

Reviews