Spears
PVC DWV Double Sanitary Tee w/ R & L Inlets
- SKU:
- P439
- Availability:
- Usually Ships Same Day
- Weight:
- 0.00 LBS
Description
PVC DWV Double Sanitary Tee w/ R & L Inlets
PVC DWV Double Sanitary Tee w/ R & L Inlets provides a multi-directional branch connection within compatible PVC DWV piping. The double sanitary tee configuration incorporates right and left inlet connections so multiple compatible drain, waste, or vent lines can connect at one fitting location.
The right and left inlet configuration combines the main piping run with opposing branch inlets within one PVC DWV fitting. Selection should account for nominal connection sizes, inlet orientation, adjoining pipe, joining requirements, piping alignment, slope where applicable, support, and available installation clearance.
Product Highlights
- PVC construction
- DWV fitting design
- Double sanitary tee
- Right and left inlets
- Multi-directional connection
- Provides opposing branch connections
- Connects multiple compatible PVC DWV lines
- Combines a main piping run with right- and left-side inlet connections
Technical Specifications
| Product Type | Double Sanitary Tee |
|---|---|
| Material | PVC |
| System Type | DWV |
| Fitting Configuration | Double Sanitary Tee |
| Inlet Configuration | Right & Left Inlets |
| Connection Function | Main Run with Opposing Branch Inlets |
| Connection Interface | Compatible PVC DWV Piping |
| Material Compatibility | Compatible PVC DWV Components |
| Joining Method | Compatible PVC DWV Joining Procedure |
| Piping Configuration | Multi-Directional Branch Connection |
| Primary Function | Provide Right and Left Branch Connections Within Compatible PVC DWV Piping |
| Selection Requirement | Match Nominal Sizes and Inlet Orientation |
Double Sanitary Tee Design
The double sanitary tee configuration provides opposing branch connections from the main DWV piping run. This allows compatible right- and left-side branch lines to connect at a common fitting location while maintaining the required piping arrangement.
The fitting orientation should be established before permanent joining so the right and left inlets correspond with the intended branch directions. Planning the installation helps coordinate adjoining pipe, nearby fittings, piping support, and available working clearance.
Right & Left Inlet Connections
The right and left inlets provide opposing branch connection points from the main fitting body. Each connection should be matched to the correct nominal size and adjoining PVC DWV pipe before permanent assembly.
The mating surfaces should be prepared using the appropriate PVC DWV joining procedure. Compatible joining materials, proper insertion, correct inlet orientation, and careful alignment help establish the connections without placing unnecessary stress on the fitting.
PVC DWV Integration
The PVC DWV construction allows the double sanitary tee to integrate into compatible drain, waste, and vent piping arrangements requiring opposing branch connections. Matching the nominal sizes and connection interfaces to the adjoining PVC pipe helps maintain the intended piping configuration.
Application suitability should be evaluated using the requirements of the complete DWV system. Adjoining materials, connection compatibility, joining materials, piping support, slope where applicable, and local installation requirements should all be considered during fitting selection.
Opposing Branch Configuration
A PVC DWV Double Sanitary Tee with Right & Left Inlets allows multiple compatible piping lines to meet within one fitting. The opposing inlet arrangement can simplify layouts where branch connections are required on both sides of the main piping run.
Installation planning should consider each branch direction, nominal connection size, adjoining pipe alignment, nearby components, and available clearance. Connected piping should align naturally so the fitting is not relied upon to correct offsets or support improperly positioned pipe.
Installation & Selection Considerations
- Confirm every nominal size.
- Verify the right and left inlet arrangement.
- Check PVC DWV compatibility.
- Match each inlet to the adjoining pipe.
- Set the fitting orientation before assembly.

Our PVC fitting specialists can help review your nominal connection sizes, DWV requirements, right and left inlet configuration, adjoining PVC pipe, branch orientation, joining requirements, piping alignment, support requirements, and available installation clearance before you order.
Frequently Asked Questions
What is a PVC DWV Double Sanitary Tee with right and left inlets used for?
It provides opposing branch connections from a compatible PVC DWV main piping run.
What do right and left inlets mean?
They identify branch connections positioned on opposite sides of the main fitting body.
What type of system is this fitting intended for?
It is intended for compatible PVC drain, waste, and vent piping arrangements.
Does fitting orientation matter?
Yes. The fitting should be positioned so the right and left inlets correspond with the intended branch directions.
How are the connections assembled?
Compatible PVC DWV components should be joined using the appropriate preparation and joining procedure for the installation.
What should I confirm before ordering?
Confirm every nominal size, right and left inlet orientation, PVC DWV compatibility, and adjoining piping arrangement.
Important Ordering & Installation Notes
- Inspect all connections before use.
- Confirm every nominal connection size.
- Verify the right and left inlet positions.
- Prepare adjoining pipe correctly.
- Set the fitting orientation before assembly.