Domestic Cleaned & Bagged Wrot Copper Male Adapter – FTG x MIP
Domestic cleaned and bagged FTG x MIP wrot copper male adapters transition from a female copper fitting socket to a male threaded connection. The male copper fitting end inserts directly into a compatible female copper sweat socket, while the male pipe-thread connection threads into a compatible female NPT component.
Select the required nominal connection size from the product options above. The selected variation determines the Cello item number, online selling price, shipping weight, cost, and other size-specific product information.
Product Highlights
- Domestic wrot copper construction
- Cleaned and individually bagged for protected handling
- Male copper fitting end x male pipe-thread connection
- FTG x MIP connection configuration
- Inserts directly into a compatible female copper fitting socket
- Threads into a compatible female NPT connection
- Provides a compact copper-fitting-to-threaded transition
- Suitable for approved soldered or brazed copper joints
- Available in 1/2", 3/4", and 1" nominal sizes
- Suitable for medical gas, laboratory, institutional, mechanical, and other controlled piping applications when approved
Technical Specifications
| Material | Wrot Copper |
|---|---|
| Product Type | Domestic Cleaned & Bagged Copper Male Adapter |
| Connection | Male Copper Fitting End x Male Pipe Thread |
| Connection Abbreviation | FTG x MIP |
| Copper Connection | Male Copper Fitting End |
| Threaded Connection | Male NPT |
| Configuration | Straight Male Adapter |
| Installation Method | Approved Soldered or Brazed Copper Joint and Male Threaded Connection |
| Applicable Copper Fitting Standard | ASME B16.22 |
| Thread Standard | NPT |
| Manufacturer | Cello Products |
| Available Sizes | 1/2", 3/4", and 1" |
How an FTG x MIP Male Adapter Works
The male copper fitting end inserts directly into a compatible female copper sweat socket. The opposite male threaded end connects to a compatible female NPT valve, fitting, equipment port, or other threaded component. The copper connection is soldered or brazed, while the threaded connection is assembled using an approved sealing method.
FTG x MIP Adapter vs. C x MIP Adapter
FTG x MIP Male Adapter
- Uses a male copper fitting end
- Inserts directly into a female copper fitting socket
- Has external male pipe threads on the opposite end
- Creates a compact fitting-to-threaded connection
C x MIP Male Adapter
- Uses a female copper sweat socket
- Fits over properly sized copper tube
- Has external male pipe threads on the opposite end
- Creates a tube-to-threaded connection
Cleaned & Bagged Construction
Each adapter is cleaned and enclosed in protective packaging to help preserve the condition of the copper fitting end and threaded connection during storage, transportation, and handling. Keep the fitting sealed in its original bag until immediately before installation.
Cleaned and bagged copper components are commonly specified for piping systems where dirt, oil, grease, moisture, metal particles, and other contaminants must be carefully controlled. Confirm that the fitting, cleaning level, packaging, joining procedure, thread-sealing method, and installation requirements satisfy the project specifications and applicable codes.
Common Applications
Clean and Controlled Piping
- Medical-gas piping installations
- Laboratory piping systems
- Institutional piping projects
- Clean mechanical piping
- Process piping requiring protected fittings
- Projects specifying cleaned and bagged copper components
Threaded Component Connections
- Female threaded valves
- Equipment and fixture connections
- Regulators and instrumentation
- Commercial mechanical systems
- Heating and cooling equipment
- Maintenance and retrofit work
Installation Guidance
- Confirm the required nominal size before ordering.
- Verify that the receiving copper connection is a compatible female fitting socket.
- Confirm that the mating threaded component has compatible female NPT threads.
- Keep the fitting sealed until immediately before installation.
- Handle the fitting using clean gloves and approved tools when required.
- Do not use the fitting if the protective package is damaged or the fitting appears contaminated.
- Inspect the male copper fitting end and male pipe threads before assembly.
- Clean and prepare the fitting end and receiving copper socket using approved procedures.
- Insert the male fitting end fully into the receiving female copper fitting socket.
- Use approved solder, brazing alloy, purge gas, flux, and joining procedures.
- Allow the copper joint to cool before assembling the threaded connection.
- Use only a thread-sealing method approved for the system and piping media.
- Prevent thread-sealing material from entering the piping system.
- Use proper wrenching techniques and avoid overtightening or overstressing the copper adapter.
- Follow applicable medical-gas procedures when installed in medical-gas piping.
- Pressure-test and inspect the completed system before placing it into service.
Product Resources
Review the Cello product catalog and NSF Annex G listing before ordering or installation.
Need Help Selecting a Cleaned & Bagged FTG x MIP Copper Adapter?
Our industrial PVF specialists can help confirm the required fitting-end size, male NPT connection, receiving copper fitting, joining method, cleanliness requirements, and product availability.
Frequently Asked Questions
What is an FTG x MIP copper male adapter?
It is a straight copper adapter with a male copper fitting end on one side and a male NPT connection on the other side.
What does FTG x MIP mean?
FTG identifies a male copper fitting end that inserts into a female copper fitting socket. MIP identifies a male pipe-thread connection that threads into a compatible female NPT component.
Does the copper end fit over copper tube?
No. The male fitting end inserts into a compatible female copper fitting socket rather than fitting over copper tube.
What connects to the male threaded end?
The male NPT connection threads into a compatible female threaded fitting, valve, equipment connection, or other component.
Is this the same as a C x MIP male adapter?
No. A C x MIP adapter has a female copper socket that fits over tube. This adapter has a male fitting end that inserts directly into another copper fitting.
Can the copper fitting end be brazed?
Yes, when brazing is appropriate and completed using approved materials, procedures, purge requirements, and applicable codes.
Can the copper fitting end be soldered?
It may be soldered when permitted by the application, project specifications, and applicable codes.
Should the threaded connection be assembled before brazing?
The copper joint should generally be completed and allowed to cool before the threaded connection is assembled. Follow the approved project procedure.
Why is the fitting cleaned and bagged?
The protective packaging helps prevent dirt, oil, grease, moisture, metal particles, and other contaminants from contacting the fitting before installation.
Is this a domestic copper fitting?
Yes. It is listed as a domestic cleaned and bagged wrot copper fitting manufactured by Cello Products.
Can it be used in medical-gas piping?
It may be used when the fitting, cleaning level, packaging, joining procedure, thread-sealing method, and installation satisfy the project specifications and applicable medical-gas requirements.
Important Ordering Notes
- Select the required nominal size before adding the product to your cart.
- The selected variation determines the Cello SKU, price, shipping weight, and cost.
- This adapter has a male copper fitting end and a male NPT connection.
- The copper fitting end inserts into a compatible female copper fitting socket.
- The male threaded end connects to a compatible female NPT component.
- This is not a C x MIP adapter that fits over copper tube.
- Keep the fitting sealed in its protective bag until installation.
- Confirm that the package is intact and the fitting is free from visible contamination.
- Use an approved thread-sealing method compatible with the piping media.
- Prevent thread-sealing material from entering the piping system.
- Use approved solder, brazing alloy, purge gas, preparation methods, and installation procedures.
- Confirm pressure, temperature, media compatibility, cleanliness, and applicable code requirements.
- Installation should be completed by qualified personnel.