Cello

Domestic Cleaned & Bagged Wrot Copper Female Adapter – FTG x FIP

(No reviews yet) Write a Review
Availability:
Usually in Stock – Ships Quickly
Weight:
0.00 LBS
*Images are for visual reference only.
  • Domestic cleaned and bagged wrot copper female adapter with FTG x FIP connection for clean and controlled piping systems.
  • Domestic cleaned and bagged wrot copper female adapter FTG x FIP infographic showing product features, applications, and available sizes from 1/4 inch through 4 inches.
$15.95 - $31.95

Represents the combined quantity sold of all the sizes under this product SKU.
Sold:
Frequently bought together:

Description

Domestic Cleaned & Bagged Wrot Copper Female Adapter – FTG x FIP

Domestic cleaned and bagged FTG x FIP wrot copper female adapters transition from a female copper fitting socket to a female threaded connection. The male copper fitting end inserts directly into a compatible female copper sweat socket, while the female pipe-thread connection accepts a compatible male NPT component.

Select the required nominal connection size from the product options above. The selected variation determines the Cello item number, online selling price, shipping weight, cost, and other size-specific product information.

Product Highlights

  • Domestic wrot copper construction
  • Cleaned and individually bagged for protected handling
  • Male copper fitting end x female pipe-thread connection
  • FTG x FIP connection configuration
  • Inserts directly into a compatible female copper fitting socket
  • Accepts a compatible male NPT component
  • Provides a compact copper-fitting-to-threaded transition
  • Suitable for approved soldered or brazed copper joints
  • Available in nominal sizes from 3/8" through 1"
  • Suitable for medical gas, laboratory, institutional, mechanical, and other controlled piping systems when approved

Technical Specifications

Material Wrot Copper
Product Type Domestic Cleaned & Bagged Copper Female Adapter
Connection Male Copper Fitting End x Female Pipe Thread
Connection Abbreviation FTG x FIP / FTG x FE
Copper Connection Male Copper Fitting End
Threaded Connection Female NPT
Configuration Straight Female Adapter
Installation Method Approved Soldered or Brazed Copper Joint and Female Threaded Connection
Applicable Copper Fitting Standard ASME B16.22
Thread Standard NPT
Manufacturer Cello Products
Available Sizes 3/8" Through 1"

How an FTG x FIP Female Adapter Works

The male copper fitting end inserts directly into a compatible female copper sweat socket. The opposite female threaded end accepts a compatible male NPT pipe, nipple, valve, regulator, gauge, instrument, or equipment connection. The copper joint is soldered or brazed, while the threaded connection is assembled using a sealing method approved for the piping system.

FTG x FIP Adapter vs. C x FIP Adapter

FTG x FIP Female Adapter

  • Uses a male copper fitting end
  • Inserts into a female copper fitting socket
  • Has female pipe threads on the opposite end
  • Creates a compact fitting-to-threaded connection

C x FIP Female Adapter

  • Uses a female copper sweat socket
  • Fits over properly sized copper tube
  • Has female pipe threads on the opposite end
  • Creates a tube-to-threaded connection

Cleaned & Bagged Construction

Each adapter is cleaned and enclosed in protective packaging to help preserve the condition of the copper joining surface and threaded connection during storage, transportation, and handling. Keep the fitting sealed in its original bag until immediately before installation.

Cleaned and bagged copper components are commonly specified for piping systems where dirt, oil, grease, moisture, metal particles, and other contaminants must be controlled. Confirm that the selected fitting, cleaning level, packaging, joining procedure, and thread-sealing method satisfy the project specifications and applicable codes.

Common Applications

Clean and Controlled Piping

  • Medical-gas piping installations
  • Laboratory piping systems
  • Institutional piping projects
  • Clean mechanical piping
  • Process piping requiring protected fittings
  • Projects specifying cleaned and bagged copper components

Threaded Component Connections

  • Valves and regulators
  • Gauges and instruments
  • Male threaded pipe nipples
  • Equipment connections
  • Commercial plumbing systems
  • Maintenance and retrofit work

Installation Guidance

  • Confirm the required nominal connection size before ordering.
  • Verify that the receiving copper connection is a compatible female fitting socket.
  • Confirm that the mating threaded component has compatible male NPT threads.
  • Keep the fitting sealed until immediately before installation.
  • Handle the fitting using clean gloves and approved tools when required.
  • Do not use the fitting if the protective package is damaged or the fitting appears contaminated.
  • Inspect the male fitting end and female pipe threads before assembly.
  • Clean and prepare the fitting end and receiving copper socket using approved procedures.
  • Insert the male fitting end fully into the receiving female copper fitting socket.
  • Use approved solder, brazing alloy, purge gas, flux, and joining procedures.
  • Allow the copper joint to cool before assembling the threaded connection.
  • Use only a thread sealant or sealing method approved for the system and piping media.
  • Prevent thread sealant from entering the piping system.
  • Use proper wrenching techniques and avoid overstressing the copper adapter.
  • Follow applicable medical-gas procedures when installed in medical-gas piping.
  • Pressure-test and inspect the completed installation before placing it into service.

Product Resources

Review the Cello product catalog and NSF Annex G listing before ordering or installation.

Need Help Selecting a Cleaned & Bagged FTG x FIP Copper Adapter?

Our industrial PVF specialists can help confirm the required fitting-end size, female NPT connection, receiving copper fitting, joining method, cleanliness requirements, and product availability.

Frequently Asked Questions

What is an FTG x FIP copper female adapter?

It is a straight copper adapter with a male copper fitting end on one side and a female NPT connection on the other side.

What does FTG x FIP mean?

FTG identifies a male copper fitting end that inserts into a female copper fitting socket. FIP identifies a female pipe-thread connection that accepts a compatible male NPT component.

What does FTG x FE mean?

FTG x FE is another description used for a male copper fitting end connected to a female threaded end.

Does the copper end fit over copper tube?

No. The male fitting end inserts into a compatible female copper fitting socket. It does not fit over copper tube like a female sweat socket.

What connects to the female threaded end?

The female NPT connection accepts compatible male threaded pipe, nipples, valves, regulators, gauges, instruments, or equipment connections.

Is this the same as a C x FIP female adapter?

No. A C x FIP adapter has a female copper socket that fits over tube. This adapter has a male fitting end that inserts into another copper fitting.

Can the copper fitting end be brazed?

Yes, when brazing is appropriate and completed using approved materials, procedures, purge requirements, and applicable codes.

Can the copper fitting end be soldered?

It may be soldered when permitted by the application, project specifications, and applicable codes.

Should the threaded component be installed before brazing?

The copper joint should generally be completed and allowed to cool before the threaded component is installed. Follow the approved project procedure.

What thread sealant should be used?

Use only a sealing method approved for the piping media, system cleanliness requirements, and applicable codes.

Why is this fitting cleaned and bagged?

The protective packaging helps prevent dirt, grease, oil, moisture, metal particles, and other contaminants from contacting the fitting before installation.

Is this a domestic copper fitting?

Yes. It is listed as a domestic cleaned and bagged wrot copper fitting manufactured by Cello Products.

Can it be used in medical-gas piping?

It may be used when the fitting, cleaning level, packaging, joining procedure, thread-sealing method, and installation satisfy the project specifications and applicable medical-gas requirements.

Important Ordering Notes

  • Select the required nominal size before adding the product to your cart.
  • The selected variation determines the Cello SKU, price, shipping weight, and cost.
  • This adapter has a male copper fitting end and a female NPT connection.
  • The fitting end inserts into a compatible female copper fitting socket.
  • The female threaded end accepts a compatible male NPT component.
  • This is not a C x FIP adapter that fits over copper tube.
  • Keep the fitting sealed in its protective bag until installation.
  • Confirm that the package is intact and the fitting is free from visible contamination.
  • Use an approved thread-sealing method compatible with the piping media.
  • Prevent thread sealant from entering the piping system.
  • Use approved solder, brazing alloy, purge gas, preparation methods, and installation procedures.
  • Confirm pressure, temperature, media compatibility, cleanliness, and applicable code requirements.
  • Installation should be completed by qualified personnel.
View AllClose