Jomar TB-150G RecircSetter™ Thermostatic Balancing Valve
Jomar TB-150G RecircSetter™ lead-free thermostatic balancing valves are designed for domestic hot-water recirculation systems where automatic thermal balancing and controlled recirculation-loop temperature are required. The valve modulates flow to maintain a constant temperature and includes actuated thermal disinfection capability for use with a building management system (BMS).
Select the required nominal pipe size and check-valve configuration from the product options above. The selected variation determines the Jomar part number, UPC, selling price, and configuration.
Product Highlights
- Thermostatic balancing valve for domestic hot-water recirculation systems
- Lead-free dezincification-resistant (DZR) brass construction
- Variable temperature set point with protective cap
- 95°F to 140°F temperature setting range
- Modulates flow to maintain constant recirculation-loop temperature
- Actuated thermal disinfection for use with a building management system (BMS)
- Drywell with temperature gauge included
- Factory-plugged 1/2" NPT temperature port
- Available with or without optional check valve
- Female NPT end connections
- NSF/ANSI/CAN 61 and NSF/ANSI/CAN 372 certified
- Conforms to ANSI B1.20.1
- Made in Italy
Technical Specifications
| Series | TB-150G RecircSetter™ |
|---|---|
| Valve Type | Thermostatic Balancing Valve |
| Application | Domestic Hot-Water Recirculation |
| Body Material | Lead-Free DZR Brass C27453 |
| Connection | Female NPT (FNPT) |
| Sizes | 1/2" and 3/4" |
| Maximum Working Pressure | 232 psi |
| Maximum Differential Pressure | 14.5 psi |
| Maximum Working Temperature | 194°F |
| Temperature Setting Range | 95°F to 140°F |
| Cv Minimum / Maximum | 0.23 / 2.10 |
| Cv Design | 0.53–0.59 |
| Cv, Actuated Disinfection | 1.16 |
| Certifications | NSF/ANSI/CAN 61; NSF/ANSI/CAN 372 |
| Thread Standard | ANSI B1.20.1 |
| Manufacturer | Jomar Valve |
Available Configurations
| Jomar Part Number | Size | Check Valve | UPC |
|---|---|---|---|
| 180-103G-A | 1/2" | Without Check Valve | 662527314826 |
| 180-104G-A | 3/4" | Without Check Valve | 662527314833 |
| 180-103G-A-C | 1/2" | With Check Valve | 662527314901 |
| 180-104G-A-C | 3/4" | With Check Valve | 662527314918 |
Common Applications
Domestic Hot-Water Recirculation
- Commercial domestic hot-water recirculation loops
- Multi-branch recirculation systems
- Hotels and hospitality facilities
- Healthcare and institutional facilities
- Schools, universities, and multi-family buildings
Automatic Thermal Balancing
- Temperature-controlled balancing of recirculation branches
- Systems requiring variable temperature set points
- BMS-controlled thermal disinfection applications
- Lead-free potable-water piping systems
- New construction and retrofit applications
Product Resources
Review the Jomar TB-150G specification sheet for dimensions, materials, pressure and temperature ratings, flow characteristics, and configuration details before installation.
Need Help Selecting a RecircSetter™?
Our industrial PVF specialists can help confirm valve size, check-valve configuration, temperature requirements, connection requirements, and application compatibility.
Frequently Asked Questions
What does the Jomar TB-150G RecircSetter™ do?
It modulates flow in a domestic hot-water recirculation loop to help maintain a constant temperature.
What temperature range can the TB-150G be set to?
Jomar specifies an adjustable temperature setting range of 95°F to 140°F.
What is the actuated thermal disinfection feature for?
It is intended for use with a building management system (BMS) to support a controlled thermal-disinfection operating mode.
Is a check valve included?
The TB-150G is offered in configurations with and without the optional check valve. Select the required configuration above.
Does it include a temperature gauge?
Yes. Jomar specifies that a drywell with temperature gauge is included.
What certifications apply?
The TB-150G is certified to NSF/ANSI/CAN 61 and NSF/ANSI/CAN 372 and conforms to ANSI B1.20.1.
Important Ordering Notes
- Select both nominal pipe size and check-valve configuration before adding the product to your cart.
- The selected variation determines the Jomar part number, UPC, and selling price.
- Confirm system pressure, temperature, flow, connection, and thermal-disinfection requirements before installation.
- Installation and commissioning should be completed by qualified personnel and comply with applicable codes and project specifications.
- Refer to the linked Jomar specification sheet for the latest manufacturer technical information.