Description

PVC SDR 35 Pipe Increaser-Reducer (Hub x Hub)

PVC SDR 35 Pipe Increaser-Reducers provide a smooth transition between different SDR 35 pipe diameters in gravity-flow, non-pressure sewer and drainage systems.

Featuring hub connections on both ends, this increaser-reducer is designed to connect two different SDR 35 PVC pipe sizes within the same drainage system. The molded transition helps maintain proper alignment and efficient flow while reducing the need for multiple fittings. Constructed from durable PVC, the fitting provides lightweight handling along with resistance to corrosion, moisture, and many compatible chemicals for dependable use in residential, commercial, and municipal underground sewer and drainage applications.

Product Highlights

  • PVC SDR 35 pipe increaser-reducer
  • Hub x Hub connection configuration
  • Transitions between different SDR 35 pipe diameters
  • Can be used as an increaser or reducer depending on flow direction and system layout
  • Designed for gravity-flow sewer and drainage systems
  • Suitable for non-pressure applications
  • Designed for solvent-weld installation
  • Helps provide a smooth pipe-size transition
  • Supports proper alignment between different pipe sizes
  • Can reduce the need for multiple transition fittings
  • Durable PVC construction
  • Lightweight for easier handling and installation
  • Resistant to corrosion
  • Resistant to moisture exposure
  • Resistant to many compatible chemicals
  • Suitable for underground installations
  • Suitable for sanitary sewer systems
  • Suitable for stormwater drainage
  • Suitable for residential applications
  • Suitable for commercial applications
  • Suitable for municipal sewer and drainage systems

Technical Specifications

Product Type PVC SDR 35 Pipe Increaser-Reducer
Material PVC
Connection Type Hub x Hub
Configuration Increaser / Reducer
Pipe Compatibility Compatible SDR 35 PVC Sewer Pipe
Joint Method Solvent Weld
System Type Sewer and Drainage
Flow Type Gravity Flow
Pressure Service Non-Pressure
Primary Function Transition Between Different SDR 35 PVC Pipe Sizes
Typical Applications Sanitary Sewer, Stormwater, Underground Drainage, Residential, Commercial, and Municipal Sewer Systems

Connection Configuration

Larger Hub Connection

The larger hub accepts the corresponding larger SDR 35 PVC pipe size for solvent-weld installation.

Smaller Hub Connection

The smaller hub accepts the corresponding smaller SDR 35 PVC pipe size, creating the size transition within the fitting.

Increaser-Reducer Design

The fitting combines two different hub diameters in a single molded transition to connect different SDR 35 pipe sizes.

Depending on system orientation, the same fitting may function as either an increaser or a reducer. The key requirement is matching each hub to the correct SDR 35 pipe size.

The gradual transition helps maintain continuity through the piping system while avoiding the additional joints that may be required when multiple separate fittings are used.

Why Choose a PVC SDR 35 Increaser-Reducer?

Integrated Size Transition

  • Connects two different SDR 35 pipe sizes
  • Functions as an increaser or reducer
  • Combines the transition into one fitting
  • Can reduce overall fitting count
  • Supports compact drainage layouts

PVC Construction

  • Corrosion resistant
  • Lightweight construction
  • Suitable for underground service
  • Resistant to moisture exposure
  • Suitable for many compatible drainage environments

Typical Applications

Sewer Systems

  • Sanitary sewer piping
  • Building sewer connections
  • Residential sewer lines
  • Commercial sewer systems
  • Municipal sewer installations

Drainage Systems

  • Stormwater drainage
  • Underground drainage
  • Gravity-flow drain systems
  • Pipe-size transitions
  • General non-pressure drainage

Construction Details

Manufactured from rigid PVC, this increaser-reducer is designed for long-term underground sewer and drainage service.

The material provides resistance to corrosion, moisture, and many compatible chemicals while remaining lightweight for easier handling during installation.

Precision-molded hub connections help provide proper fit and alignment with the corresponding SDR 35 PVC pipe sizes.

Installation

Verify both nominal hub sizes before installation and confirm which side connects to the larger SDR 35 pipe and which side connects to the smaller pipe.

Cut both mating PVC pipe ends square and remove burrs or debris that could interfere with proper insertion.

Clean and prepare the pipe ends and fitting hubs according to accepted PVC solvent-weld installation procedures.

Dry-fit both pipe sections into the fitting before applying primer or solvent cement to confirm size compatibility, insertion depth, orientation, and alignment.

Apply approved PVC primer and solvent cement as required for the piping system and fully seat each pipe into its corresponding hub.

Maintain proper alignment while the joints set and allow the solvent-weld connections to cure according to the solvent cement manufacturer's recommendations before placing the drainage system into service.

Willy knows his pipe fittings
Ask Willy: Need Help Selecting a PVC SDR 35 Pipe Increaser-Reducer?

Our piping specialists can help review your larger and smaller pipe sizes, SDR 35 compatibility, flow layout, and sewer or drainage application before you order.

Email the GetPipe.com Team Visit Quick Support

Frequently Asked Questions

What is a PVC SDR 35 pipe increaser-reducer used for?

It is used to connect two different SDR 35 PVC pipe diameters within a gravity-flow sewer or drainage system.

Why is it called an increaser-reducer?

The fitting can function as either an increaser or a reducer depending on the direction of the piping layout and which size is upstream or downstream.

What does Hub x Hub mean?

It means both ends are socket-style hub connections designed to receive compatible SDR 35 PVC pipe.

Are both hubs the same size?

No. An increaser-reducer is specifically designed with different hub sizes so it can transition between two pipe diameters.

How is the fitting installed?

Both hub connections are intended for solvent-weld installation using compatible PVC preparation materials, primer, and solvent cement as required.

Is this fitting designed for pressure piping?

No. The supplied product information identifies it for non-pressure gravity-flow sewer and drainage applications.

Can it be used underground?

Yes. The supplied product information identifies underground sewer and drainage systems as typical applications.

Can it be used in sanitary sewer systems?

Yes. Sanitary sewer service is identified as an intended application.

Can it be used for stormwater drainage?

Yes. The supplied product information identifies stormwater systems as a suitable application.

Does the fitting help reduce the number of joints?

It can. Because the pipe-size transition is incorporated into one fitting, fewer separate transition components may be needed.

Does pipe orientation matter?

Yes. Confirm which hub connects to each pipe size and make sure the fitting orientation is appropriate for the intended drainage layout.

What should I verify before ordering?

Confirm both SDR 35 pipe sizes, the required increase or reduction, system orientation, application type, and compatibility with the intended sewer or drainage system.

Important Ordering & Installation Notes

  • This listing is for a PVC SDR 35 Pipe Increaser-Reducer with Hub x Hub connections.
  • Verify both nominal hub sizes before ordering.
  • The two hub sizes are different.
  • Confirm which hub connects to the larger SDR 35 pipe.
  • Confirm which hub connects to the smaller SDR 35 pipe.
  • The fitting may function as either an increaser or reducer depending on system orientation.
  • Both hubs are designed to receive compatible SDR 35 PVC pipe.
  • Do not assume both ends accept the same pipe size.
  • Confirm the intended pipe-size transition before installation.
  • This fitting is intended for gravity-flow sewer and drainage applications.
  • This fitting is intended for non-pressure service.
  • Dry-fit both pipe sections before applying primer or solvent cement.
  • Confirm correct pipe insertion depth and alignment before final assembly.
  • Cut pipe ends square before installation.
  • Remove burrs and debris from mating pipe ends.
  • Clean and prepare all mating surfaces before solvent welding.
  • Use approved PVC primer and solvent cement according to manufacturer instructions.
  • Fully seat each pipe into the correct hub.
  • Maintain proper alignment while the joints set.
  • Allow completed solvent-weld joints to cure according to the cement manufacturer's recommendations before service.
  • Suitable applications may include sanitary sewer, stormwater, and underground drainage systems.
  • Verify installation requirements for residential, commercial, or municipal applications.
  • Consult manufacturer documentation for complete dimensions and available size combinations.
  • Consult manufacturer documentation for installation and operating limitations.
  • Follow applicable plumbing, sewer, and drainage codes.