Lesso America
PVC SDR 35 Fitting Cleanout Adapter W/ C.O. Plug (SPG x FPT)
- SKU:
- LSW105X
- Availability:
- Usually Ships Same Day
- Weight:
- 0.00 LBS
Description
PVC SDR 35 Fitting Cleanout Adapter W/ C.O. Plug (SPG x FPT)
PVC SDR 35 Cleanout Adapters with Plug provide a dedicated, serviceable access point for inspection, cleaning, flushing, and maintenance in non-pressure sewer and drainage systems.
Featuring a spigot (SPG) connection on one end and a female pipe thread (FPT) cleanout opening on the other, this fitting is designed to integrate with compatible SDR 35 sewer fittings while providing removable threaded access to the piping system. The included cleanout plug seals the threaded opening during normal service and can be removed when access is needed for inspection or maintenance. Constructed from durable PVC, the adapter is suitable for sanitary sewer, stormwater, wastewater, and underground drainage applications.
Product Highlights
- PVC SDR 35 cleanout adapter with cleanout plug
- Spigot x Female Pipe Thread (FPT) configuration
- Includes threaded cleanout plug
- Provides dedicated inspection and maintenance access
- Supports cleaning, flushing, rodding, and blockage removal
- Spigot end fits into a compatible SDR 35 hub
- Designed for solvent-weld installation at the spigot connection
- Female threaded opening remains serviceable
- Removable plug allows repeated access as needed
- Durable rigid PVC construction
- Lightweight for easier handling and installation
- Resistant to corrosion
- Resistant to moisture exposure
- Resistant to many compatible chemicals
- Suitable for underground installations
- Suitable for sanitary sewer systems
- Suitable for stormwater drainage
- Suitable for wastewater piping
- Designed for non-pressure applications
- Useful for new installations, repairs, and maintenance access points
Technical Specifications
| Product Type | PVC SDR 35 Fitting Cleanout Adapter with Cleanout Plug |
|---|---|
| Material | PVC |
| Connection Type | Spigot (SPG) x Female Pipe Thread (FPT) |
| Sewer-Side Connection | SDR 35 Spigot |
| Cleanout Connection | Female Pipe Thread (FPT) |
| Included Component | Threaded Cleanout Plug |
| Joint Method | Solvent Weld x Threaded |
| System Type | Sewer and Drainage |
| Pressure Service | Non-Pressure |
| Primary Function | Provide Removable Threaded Cleanout Access in an SDR 35 Sewer or Drainage System |
| Typical Applications | Sanitary Sewer, Stormwater, Wastewater, Underground Drainage, Inspection, Cleaning, and Maintenance |
Connection Configuration
SDR 35 Spigot
The spigot end is designed to fit into a compatible SDR 35 sewer hub for solvent-weld installation.
Female Threaded Cleanout with Plug
The FPT opening accepts the included male-threaded cleanout plug, creating a removable closure for routine operation and future maintenance access.
Cleanout Access Design
This fitting creates a dedicated access point in an SDR 35 sewer or drainage system without requiring the piping to be cut open for routine maintenance.
The spigot end becomes part of the permanent piping assembly through a solvent-weld connection into a compatible hub.
The opposite female-threaded opening is sealed by the included cleanout plug during normal operation. When inspection or cleaning is required, the plug can be removed to provide direct access to the line.
Why Choose a PVC SDR 35 Cleanout Adapter with Plug?
Ready-to-Use Cleanout
- Includes matching cleanout plug
- Provides a complete service-access point
- Allows repeated access for maintenance
- Supports rodding and cleaning operations
- Convenient for inspection and flushing
Compact Integration
- Spigot end fits directly into a compatible hub
- Compact fitting-to-fitting connection
- Can reduce the need for additional couplings
- Designed for solvent-weld installation
- Suitable for SDR 35 sewer systems
Typical Applications
Sewer & Drainage
- Sanitary sewer systems
- Stormwater drainage
- Wastewater piping
- Underground drainage
- Building sewer connections
Maintenance Access
- Cleanout locations
- Inspection points
- Drain-line cleaning
- Rodding access
- Flushing and blockage removal
Construction Details
Manufactured from high-strength PVC, this cleanout adapter is designed for dependable long-term service in underground sewer and drainage environments.
The PVC material provides resistance to corrosion, moisture, and many compatible chemicals while remaining lightweight for easier handling during installation.
The molded spigot connection is designed to fit into a compatible SDR 35 hub, while the female threaded opening and included plug create a serviceable closure for ongoing maintenance access.
Installation
Verify the nominal spigot size, mating SDR 35 hub size, female thread size, and cleanout plug size before installation.
Clean and prepare the spigot end and mating SDR 35 hub according to accepted PVC solvent-weld installation procedures.
Dry-fit the adapter before applying primer or solvent cement to confirm insertion depth, orientation, and accessibility of the cleanout opening.
Apply approved PVC primer and solvent cement as required and fully seat the spigot into the compatible SDR 35 hub.
Install the included cleanout plug using a thread-sealing method compatible with PVC and approved for the intended application. Avoid overtightening the plastic threaded connection.
Position the fitting so the cleanout plug remains accessible after installation and provide sufficient working clearance for future removal and maintenance.
Allow the solvent-weld joint to cure according to the solvent cement manufacturer's recommendations before placing the system into service.

Our piping specialists can help review your SDR 35 hub size, spigot size, cleanout thread size, and sewer or drainage application before you order.
Email the GetPipe.com Team Visit Quick SupportFrequently Asked Questions
What is a PVC SDR 35 cleanout adapter with plug used for?
It is used to provide a removable access point for inspection, cleaning, flushing, and maintenance in an SDR 35 sewer or drainage system.
What does SPG x FPT mean?
It means one end is a spigot connection designed to fit into a compatible hub, while the opposite end has female pipe threads.
What does SPG mean?
SPG means spigot. The spigot end inserts into a compatible SDR 35 hub rather than receiving pipe inside a socket.
What does FPT mean?
FPT means female pipe thread. The threaded opening accepts the included male-threaded cleanout plug.
Is the cleanout plug included?
Yes. The supplied product information specifically states that this version includes a threaded cleanout plug.
Can the cleanout plug be removed after installation?
Yes. The plug is intended to remain removable so the piping system can be accessed for inspection and maintenance.
What maintenance can be performed through the cleanout?
The supplied product information identifies inspection, cleaning, flushing, and rodding as typical maintenance uses.
How is the spigot end installed?
The spigot end is intended for solvent-weld installation into a compatible SDR 35 sewer hub.
Should the threaded cleanout connection be solvent welded?
No. The threaded opening and cleanout plug should remain mechanically removable for service access.
Can any thread sealant be used on the plug?
No. Use only a thread-sealing method that is compatible with PVC and appropriate for the intended drainage application.
Is this fitting intended for pressure service?
No. The supplied product information identifies it for non-pressure sewer, stormwater, wastewater, and drainage systems.
What should I verify before ordering?
Confirm the SDR 35 spigot size, mating hub size, female thread size, included cleanout plug size, and compatibility with the intended sewer or drainage system.
Important Ordering & Installation Notes
- This listing is for a PVC SDR 35 Fitting Cleanout Adapter with C.O. Plug.
- Connection configuration is SPG x FPT.
- A threaded cleanout plug is included.
- Verify both nominal connection sizes before ordering.
- Confirm the SDR 35 spigot size and mating hub size.
- Confirm the female pipe thread and cleanout plug size.
- The spigot end is designed to fit into a compatible SDR 35 hub.
- The FPT opening accepts the included male-threaded cleanout plug.
- The spigot connection is intended for solvent-weld installation.
- The cleanout plug is intended to remain removable for service access.
- Position the fitting so the cleanout remains accessible after installation.
- Provide sufficient working clearance for plug removal, inspection, and cleaning.
- Dry-fit the adapter before applying primer or solvent cement.
- Confirm proper insertion depth and cleanout orientation before final assembly.
- Use approved PVC primer and solvent cement according to manufacturer instructions.
- Fully seat the spigot into the compatible SDR 35 hub.
- Use only PVC-compatible thread-sealing materials on the cleanout plug.
- Avoid excessive thread sealant.
- Avoid overtightening the plastic cleanout plug.
- Remove the plug only when appropriate for inspection or maintenance.
- Reinstall and secure the plug before returning the system to normal service.
- This fitting is intended for non-pressure sewer and drainage applications.
- Suitable applications may include sanitary sewer, stormwater, wastewater, and underground drainage systems.
- Allow the solvent-weld joint to cure according to the cement manufacturer's recommendations before service.
- Consult manufacturer documentation for complete dimensions and thread details.
- Consult manufacturer documentation for installation and operating limitations.
- Follow applicable plumbing, sewer, and drainage codes.