PVC DWV Fitting Cleanout Adapter w/C.O Plug (SPG x FPT)

PVC DWV Cleanout Adapters with Cleanout Plug provide a convenient, serviceable access point for inspection, cleaning, and maintenance of non-pressurized drain, waste, and vent piping systems.

Featuring a male spigot (SPG) end and a female pipe thread (FPT) opening with an included removable cleanout plug, this fitting is designed to install into a compatible hub while providing easy future access to the DWV system. Durable PVC construction offers corrosion resistance and dependable performance in residential, commercial, and industrial plumbing installations.

Product Highlights

  • PVC DWV cleanout adapter
  • Spigot (SPG) x Female Pipe Thread (FPT)
  • Includes removable cleanout plug
  • Creates a dedicated maintenance access point
  • Male spigot end fits into a compatible hub fitting
  • Female threaded opening accepts the included cleanout plug
  • Designed for non-pressurized drain, waste, and vent systems
  • Allows convenient inspection and cleaning access
  • Durable corrosion-resistant PVC construction
  • Suitable for residential, commercial, and industrial plumbing systems

Technical Specifications

Product Type DWV Cleanout Adapter with Plug
Material PVC
Connection Type Spigot (SPG) x Female Pipe Thread (FPT)
Spigot Connection Fits Into Compatible Hub
Threaded Connection Female Pipe Thread (FPT)
Included Component Removable Cleanout Plug
System Type Drain, Waste & Vent (DWV)
Pressure Service Non-Pressure
Primary Function Provide Threaded Cleanout Access
Typical Applications Residential, Commercial, and Industrial DWV Systems

Connection Configuration

Male Spigot End

The SPG end is designed to fit into a compatible PVC hub fitting for connection to the permanent DWV piping system.

Cleanout Access

The adapter creates a service opening that can be accessed when inspecting, clearing, or maintaining the drainage system.

Removable Plug

The included threaded cleanout plug closes the female threaded opening and can be removed whenever access to the piping system is required.

Construction Details

The fitting is manufactured from durable PVC for corrosion resistance and long-term service in compatible non-pressure drain, waste, and vent systems.

The male spigot end installs into a compatible hub fitting, allowing the adapter to become part of the permanent DWV piping system.

The female threaded opening and included removable cleanout plug create a reusable maintenance point that can be opened when service is required and resealed afterward.

Why Choose a Cleanout Adapter with Plug?

Ready-to-Use Cleanout

  • Cleanout plug included
  • Creates a complete access point
  • Provides removable threaded closure
  • Useful for new installations and repairs
  • Reduces the need to source a separate plug

Maintenance Access

  • Helps simplify clearing blockages
  • Supports drain inspection
  • Allows repeated access when needed
  • Provides a dedicated service location
  • Helps avoid cutting into piping for access

Typical Applications

Residential DWV Systems

  • Building drain cleanouts
  • Branch drain access
  • Fixture drain systems
  • Horizontal drainage piping
  • General maintenance access

Commercial & Industrial DWV

  • Commercial drainage systems
  • Waste piping cleanouts
  • Building service piping
  • Maintenance access points
  • Compatible industrial drainage systems

Installation Considerations

Install the spigot end into a compatible PVC hub using the appropriate solvent-weld procedure. Clean and prepare mating surfaces and use compatible PVC primer and solvent cement where required.

Install the included cleanout plug into the female threaded opening using a sealing method suitable for PVC threaded connections and the intended DWV application.

Position the fitting so the cleanout plug remains accessible after installation for future inspection, cleaning, and maintenance.

Willy knows his pipe fittings
Ask Willy: Need Help Selecting a PVC DWV Cleanout Adapter?

Our plumbing specialists can help review your pipe size, spigot connection, cleanout requirements, DWV application, and installation location before you order.

Email the GetPipe.com Team Visit Quick Support

Frequently Asked Questions

What is a PVC DWV cleanout adapter?

A cleanout adapter provides a removable access point in a drain, waste, and vent system for inspection, cleaning, and maintenance.

Does this fitting include the cleanout plug?

Yes. The supplied product information identifies an included removable cleanout plug.

What does SPG mean?

SPG means spigot. The male spigot end is designed to fit into a compatible hub fitting.

What does FPT mean?

FPT means Female Pipe Thread and refers to the internally threaded opening that accepts the cleanout plug.

Why is a cleanout useful?

A cleanout provides access to the piping system so blockages can be cleared and the drain can be inspected or maintained without cutting into the pipe.

Can the plug be removed after installation?

Yes. The plug is designed to be removable so the cleanout can be accessed for future service.

Does the spigot end fit into a hub?

Yes. The supplied product information identifies the male spigot end as fitting into a compatible hub fitting.

Is this fitting intended for pressure service?

No. This product is intended for non-pressurized drain, waste, and vent systems.

What material is the adapter made from?

The adapter is manufactured from durable, corrosion-resistant PVC.

Should the cleanout remain accessible?

Yes. The cleanout should be positioned so the plug can be reached for future inspection and maintenance.

What should I verify before ordering?

Confirm nominal size, spigot-to-hub compatibility, threaded cleanout size, DWV application, and installation location.

Important Ordering & Installation Notes

  • This listing is for a PVC DWV Fitting Cleanout Adapter with Cleanout Plug.
  • The connection configuration is SPG x FPT.
  • A removable cleanout plug is included as identified in the supplied product information.
  • Verify the required nominal connection size before ordering.
  • The male spigot end is designed to fit into a compatible PVC hub fitting.
  • The included plug installs into the female threaded opening.
  • Designed for non-pressurized drain, waste, and vent applications.
  • Use compatible PVC primer and solvent cement on the spigot-side connection where required.
  • Clean and prepare mating surfaces before solvent welding.
  • Allow solvent-weld joints to cure according to the cement manufacturer's recommendations.
  • Use a sealing method suitable for PVC threaded connections when installing the cleanout plug.
  • Avoid overtightening the cleanout plug.
  • Position the fitting so the cleanout remains accessible after installation.
  • Do not permanently cover or obstruct required cleanout access.
  • Do not use this fitting for pressure applications.
  • Check completed connections for proper assembly before normal use.
  • Follow applicable plumbing codes and installation requirements.