PVC Sch. 80 Van Stone Flange (Spigot x Multi Bolt)
PVC Sch. 80 Van Stone Flange (Spigot x Multi Bolt) provides a detachable flanged transition using a spigot connection and a multi-bolt flange interface. The spigot end fits into an appropriately sized compatible receiving socket, while the flange side connects to a compatible mating flange.
The Van Stone flange configuration combines a spigot connection with a multi-bolt flange arrangement for integration into compatible Schedule 80 PVC piping. Selection should account for nominal size, Schedule 80 PVC compatibility, receiving socket, adjoining flange configuration, bolt-hole alignment, gasket selection, piping support, and available installation clearance.
Product Highlights
- PVC construction
- Schedule 80 design
- Van Stone flange configuration
- Multi-bolt flange interface
- Spigot connection
- Provides a detachable piping connection
- Connects a compatible receiving socket to a mating flange
- Provides a spigot-to-flange transition within Schedule 80 PVC piping
Technical Specifications
| Product Type | Van Stone Flange |
|---|---|
| Material | PVC |
| Schedule | Schedule 80 |
| Connection | Spigot x Multi Bolt |
| Connection Count | Two |
| Fitting Configuration | Van Stone Flange |
| Spigot Interface | Compatible Receiving Socket |
| Flange Interface | Compatible Multi-Bolt Mating Flange |
| Connection Style | Spigot x Bolted Flange |
| Joining Method | Compatible PVC Solvent-Cement Joining x Bolted Flange Connection |
| Piping Configuration | Spigot-to-Flange Transition |
| Primary Function | Provide a Detachable Flanged Connection from a Compatible Schedule 80 PVC Socket Connection |
Van Stone Flange Design
The Van Stone flange configuration provides a detachable connection between compatible PVC piping and an adjoining flanged component. The multi-bolt flange interface allows the piping joint to be separated when access to adjoining piping or equipment is required.
The flange should be installed with adequate access for bolt placement, tightening, inspection, and future servicing. Adjoining piping and equipment should be aligned and supported so the flange connection is not relied upon to correct piping offsets or carry unnecessary mechanical loads.
Spigot & Multi-Bolt Connections
The spigot connection fits into an appropriately sized compatible receiving socket, while the multi-bolt flange interface connects to a compatible mating flange. Each connection should be matched to the intended adjoining component before permanent assembly.
The spigot and receiving socket should be prepared using the appropriate PVC solvent-cement joining procedure. At the flanged connection, gasket placement, bolt-hole alignment, mating-flange condition, and even bolt tightening should be considered during assembly.
Schedule 80 PVC Integration
The Schedule 80 PVC construction allows the flange to integrate into compatible PVC piping arrangements requiring a detachable spigot-to-flange transition. Matching the nominal size, spigot interface, and flange arrangement to the adjoining components helps maintain the intended piping configuration.
Application suitability should be evaluated using the requirements of the complete piping system rather than the schedule designation alone. Intended service conditions, adjoining materials, connection compatibility, gasket selection, joining materials, piping support, and applicable practices should all be considered during fitting selection.
Multi-Bolt Flange Connection
The multi-bolt flange interface provides the bolted connection used to join the Van Stone flange to a compatible mating flange. Proper bolt-hole alignment and gasket positioning should be established before tightening the connection.
Installation planning should consider flange alignment, gasket placement, bolt access, surrounding components, and available service clearance. The adjoining piping should be properly supported so the completed flange assembly remains aligned without unnecessary external stress.
Installation & Selection Considerations
- Confirm the nominal size.
- Verify the spigot x multi-bolt configuration.
- Check Schedule 80 PVC compatibility.
- Confirm the receiving socket and mating flange.
- Allow adequate clearance for bolted assembly.

Our PVC fitting specialists can help review your nominal size, Schedule 80 requirements, spigot x multi-bolt configuration, receiving socket, adjoining flange, gasket requirements, bolt-hole alignment, piping support, and available installation clearance before you order.
Frequently Asked Questions
What is a PVC Sch. 80 Van Stone Flange used for?
It provides a detachable flanged transition between a compatible Schedule 80 PVC socket connection and a compatible mating flange.
What does Spigot x Multi Bolt mean?
It identifies a spigot connection for a compatible receiving socket and a multi-bolt flange interface for connection to a mating flange.
What connects to the spigot end?
The spigot end fits into an appropriately sized compatible receiving socket.
What connects to the flange side?
The flange side connects to an appropriately sized compatible mating flange using the applicable bolted connection arrangement.
Does the flange connection use a gasket?
The completed flanged joint should use the gasket arrangement appropriate for the mating components and intended piping application.
What should I confirm before ordering?
Confirm the nominal size, Schedule 80 PVC compatibility, spigot connection, receiving socket, multi-bolt flange arrangement, and mating flange.
Important Ordering & Installation Notes
- Inspect both connection interfaces before use.
- Confirm the nominal connection size.
- Prepare the PVC spigot connection correctly.
- Align the mating flange before tightening bolts.
- Confirm gasket placement before final assembly.