Spears
PVC-95 Flexible Blue Solvent Cement
- SKU:
- PVC95B
- Availability:
- Usually Ships Same Day
- Weight:
- 0.00 LBS
Description
PVC-95 Flexible Blue Solvent Cement
Spears® Manufacturing PVC-95 Flexible Blue Solvent Cement is a fast-setting, medium-bodied PVC solvent cement specially formulated for joining compatible flexible-to-flexible and flexible-to-rigid PVC pipe and fitting connections.
The flexible formulation is designed to maintain high-strength, flexible joints while supporting interference-fit PVC connections through 6" diameter and Schedule 80 applications through 3", making it well suited for compatible piping systems where flexibility at the completed joint is important.
Product Highlights
- Blue cement
- Fast-setting formula
- Medium-bodied consistency
- Maintains flexible PVC joints
- Designed for high-strength connections
- For flexible-to-flexible PVC connections
- For flexible-to-rigid PVC connections through 6"
- Compatible with Schedule 80 applications through 3"
Technical Specifications
| Product Type | Low VOC Flexible PVC Solvent Cement |
|---|---|
| Manufacturer | Spears® Manufacturing |
| Product Series | PVC-95 Flexible |
| Color | Blue |
| Resin | PVC |
| Body | Medium Body |
| Relative Set | Fast |
| Specific Gravity | 0.945 ± 0.04 |
| Minimum Viscosity | 500 cP @ 73 ± 2°F |
| Connection Types | Flexible-to-Flexible & Flexible-to-Rigid PVC |
| General Maximum Size | Through 6" Interference Fit |
| Schedule 80 Maximum Size | Through 3" Interference Fit |
| ASTM Standard | ASTM D2564 |
| Maximum VOC Emissions | 425 g/L |
| Shelf Life | 3 Years from Date Stamped on Container |
Flexible PVC Joining
PVC-95 Flexible is specially formulated for compatible flexible PVC piping systems where ordinary rigid-PVC solvent cement may not provide the joint characteristics required for movement and flexibility within the completed connection.
The medium-bodied consistency and fast relative set support properly prepared flexible-to-flexible and flexible-to-rigid PVC connections while helping maintain the high-strength, flexible joint characteristics intended for these specialized piping applications.
Flexible-to-Flexible & Flexible-to-Rigid Connections
PVC-95 is designed for both flexible-to-flexible and flexible-to-rigid PVC connections, allowing the same specialized solvent cement to be used where compatible flexible PVC components connect either to other flexible components or to rigid PVC piping and fittings.
Always verify that the pipe and fitting materials are compatible with PVC-95 and confirm the nominal size, schedule, interference fit, service conditions, and applicable Spears® joining requirements before assembling the connection.
High-Strength Flexible Joints
The PVC-95 formulation is designed to maintain high-strength, flexible joints, providing an important advantage in compatible piping applications where the completed connection must retain greater flexibility than a conventional rigid PVC joint.
Proper preparation and assembly remain essential to joint performance, so mating surfaces should be clean and properly prepared and the completed connection should receive the required set and cure time before the piping system is placed into service.
Size & Schedule Compatibility
PVC-95 Flexible is suitable for compatible flexible-to-flexible and flexible-to-rigid PVC connections with interference fit through 6", providing coverage across a broad range of flexible PVC piping sizes and configurations.
Schedule 80 applications are limited to interference-fit connections through 3", so the pipe schedule and nominal size should always be confirmed before selecting PVC-95 and beginning the solvent-cement joining procedure.
Installation & Selection Considerations
- Check the cement before use.
- Keep the container tightly sealed.
- Confirm flexible PVC material compatibility.
- Verify pipe size and schedule are within product limits.
- Follow Spears® joining and cure requirements before placing the system in service.

Review the supplied Spears® documents for additional PVC-95 specifications, flexible-to-flexible and flexible-to-rigid PVC compatibility, size and Schedule 80 limitations, product standards, handling guidance, and solvent-cement joining information before use.
Need Help Selecting Flexible PVC Solvent Cement?
Our PVC product specialists can help review your flexible PVC application, pipe size, schedule, flexible-to-flexible or flexible-to-rigid connection, fitting configuration, service conditions, and installation requirements before you order.
Frequently Asked Questions
What color is PVC-95 cement?
This PVC-95 product is supplied in blue, providing visible cement coverage while installers assemble compatible flexible-to-flexible and flexible-to-rigid PVC connections.
How fast does PVC-95 set?
Spears® identifies PVC-95 as a fast-setting, medium-bodied PVC solvent cement specially formulated for compatible flexible PVC piping connections.
What is PVC-95 designed for?
PVC-95 is specifically formulated for joining compatible flexible-to-flexible and flexible-to-rigid PVC connections while maintaining high-strength, flexible joints.
Can PVC-95 connect flexible PVC to rigid PVC?
Yes. Flexible-to-rigid PVC joining is one of the primary intended uses of PVC-95 when the selected pipe and fitting materials are compatible with the solvent cement.
Can PVC-95 join flexible PVC to flexible PVC?
Yes. PVC-95 is specifically formulated for compatible flexible-to-flexible PVC connections and is designed to maintain flexibility within the completed high-strength joint.
What size PVC can PVC-95 be used with?
PVC-95 is suitable for compatible flexible-to-flexible and flexible-to-rigid PVC connections with interference fit through 6" diameter.
Can PVC-95 be used with Schedule 80 PVC?
Yes. PVC-95 is suitable for compatible Schedule 80 PVC interference-fit connections through 3" diameter when installed according to the applicable Spears® joining requirements.
What is the shelf life of PVC-95?
PVC-95 has a specified shelf life of three years from the date stamped on the bottom of the container when properly stored and tightly sealed between uses.
Important Ordering & Installation Notes
- Check the container date before use.
- Do not add thinner to thickened cement.
- Confirm flexible PVC compatibility before joining.
- Verify pipe size and Schedule 80 limitations before use.
- Allow the completed solvent-cement connection to cure before placing the system in service.