Midland Brass In-Line Check Valve Vertical or Horizontal

Midland Brass In-Line Check Valves are designed to provide dependable one-way flow control while automatically preventing reverse flow in compatible liquid piping systems.

Suitable for either vertical or horizontal installation, these compact valves combine corrosion-resistant brass construction with female threaded connections and a space-saving inline body. Available in sizes from 1/8" through 1", they are well suited for residential, commercial, and industrial fluid handling applications.

Product Highlights

  • Midland brass in-line check valve
  • Automatically prevents reverse flow
  • Suitable for vertical or horizontal installation
  • Corrosion-resistant brass construction
  • Female threaded pipe connections
  • Compact inline body
  • Low-maintenance operation
  • Designed for efficient one-way flow control
  • Available in 1/8", 1/4", 1/2", 3/4", and 1" sizes
  • Suitable for compatible residential, commercial, and industrial liquid systems

Technical Specifications

Product Type In-Line Check Valve
Brand Midland
Body Material Brass
Connection Type Female Threaded
Operation Automatic
Primary Function Reverse Flow Prevention
Installation Orientation Vertical or Horizontal
Available Sizes 1/8", 1/4", 1/2", 3/4", and 1"
Typical Service Compatible Liquid Piping Systems
Typical Applications Residential, Commercial, and Industrial Fluid Handling

Valve Configuration

Inline Body

The compact body installs directly in the piping run, making it useful where available space is limited.

Female Threaded Ends

Female threaded connections provide straightforward installation into compatible male-threaded piping and fittings.

Flexible Orientation

The valve is designed for dependable operation in either vertical or horizontal piping when installed in the correct flow direction.

Construction Details

The valve body is manufactured from durable brass to provide corrosion resistance and dependable service in compatible fluid handling systems.

The compact in-line configuration helps maintain a simple piping layout while providing automatic one-way flow control.

Its internal check mechanism is designed to allow forward flow and close when flow stops or reverses, helping protect connected equipment and piping from unwanted backflow.

Why Use an In-Line Check Valve?

Automatic Backflow Protection

  • No manual operation required
  • Helps prevent reverse flow
  • Protects piping and equipment
  • Works automatically with system flow
  • Suitable for continuous service applications

Compact Installation

  • Space-saving inline body
  • Simple threaded connections
  • Useful in tight piping layouts
  • Multiple sizes available
  • Vertical or horizontal installation flexibility

Available Sizes

  • 1/8"
  • 1/4"
  • 1/2"
  • 3/4"
  • 1"

Typical Applications

Residential & Commercial

  • Water piping
  • General plumbing systems
  • Utility piping
  • Equipment protection
  • General liquid transfer

Industrial Systems

  • Process support piping
  • Pump discharge lines
  • Fluid transfer systems
  • Equipment inlet protection
  • Compatible liquid service

Vertical vs. Horizontal Installation

Horizontal Installation

The valve may be installed in a horizontal piping run when the flow arrow on the body points in the normal direction of system flow.

Vertical Installation

The valve is also identified as suitable for vertical piping. Always maintain the manufacturer-specified flow direction and installation requirements.

Willy knows his pipe sizes
Ask Willy: Need Help Selecting a Ball Valve?

Our valve, fitting, and industrial product specialists can help review your valve size, FIP connection requirements, pressure rating, handle configuration, media compatibility, and application before you order.

Email the GetPipe.com Team Visit Quick Support

Frequently Asked Questions

What is this valve used for?

This valve is designed to permit flow in one direction while automatically helping prevent reverse flow.

What material is the valve made from?

The supplied product information identifies corrosion-resistant brass construction.

What type of connections does it use?

The valve uses female threaded pipe connections.

Can this valve be installed horizontally?

Yes. The supplied product information identifies horizontal installation as suitable.

Can this valve be installed vertically?

Yes. The supplied product information also identifies vertical installation as suitable when the proper flow direction is maintained.

What sizes are available?

The supplied product information identifies 1/8", 1/4", 1/2", 3/4", and 1" sizes.

Does the valve require manual operation?

No. The check valve is designed to operate automatically with system flow.

Does installation direction matter?

Yes. Install the valve with the flow arrow on the body pointing in the intended direction of normal system flow.

What should I verify before ordering?

Confirm valve size, thread compatibility, installation orientation, intended media, pressure, and temperature requirements before ordering.

Important Ordering & Installation Notes

  • This listing is for Midland Brass In-Line Check Valves.
  • Available sizes are 1/8", 1/4", 1/2", 3/4", and 1".
  • Confirm the required nominal valve size before ordering.
  • Verify female thread compatibility with the intended piping system.
  • Install with the flow arrow pointing in the intended direction of system flow.
  • Suitable for vertical or horizontal installation according to the supplied product information.
  • Verify brass compatibility with the intended media.
  • Confirm system pressure and operating temperature requirements before installation.
  • Use an appropriate thread sealant where permitted.
  • Avoid excessive installation torque that could damage the valve or threaded connections.
  • Support connected piping to prevent excessive mechanical load on the valve.
  • Check operation after installation to confirm proper forward flow and reverse-flow closure.
  • Fully isolate and depressurize the system before maintenance or replacement.
  • Follow applicable plumbing or mechanical codes and manufacturer recommendations.