Midland Industries

Midland Brass Swing Check Valve

(No reviews yet) Write a Review
Availability:
Allow 2-3 Days to Ship
Weight:
0.00 LBS
*Images are for visual reference only.
  • Midland Brass Swing Check Valve
  • Midland Industries
$11.51 - $268.03

Represents the combined quantity sold of all the sizes under this product SKU.
Sold:
Frequently bought together:

Description

Midland Brass Swing Check Valve

Midland Brass Swing Check Valves are designed to provide dependable one-way flow control by automatically preventing reverse flow in compatible piping systems.

Constructed from durable brass with a swing-type internal disc, these valves offer reliable performance in water, oil, air, and other compatible non-corrosive fluid applications. Available in sizes from 1/2" through 4", they are well suited for residential, commercial, industrial, and general plumbing systems.

Product Highlights

  • Midland brass swing check valve
  • Automatic swing-disc operation
  • Helps prevent reverse flow
  • Female IPS threaded connections
  • Durable brass construction
  • Corrosion-resistant for compatible service
  • Low pressure drop during forward flow
  • Suitable for water, oil, air, and other compatible fluids
  • Available in sizes from 1/2" through 4"
  • Maintenance-friendly check valve design

Technical Specifications

Product Type Swing Check Valve
Brand Midland
Body Material Brass
Connection Type Female IPS Threaded
Check Mechanism Hinged Swing Disc
Operation Automatic
Primary Function Reverse Flow Prevention
Available Sizes 1/2" through 4"
Typical Media Water, Oil, Air, and Other Compatible Fluids
Installation Orientation Horizontal or Vertical with Upward Flow, as Applicable

Valve Configuration

Swing Disc

The hinged internal disc swings open with forward flow and closes automatically when flow stops or reverses.

Female IPS Ends

Female IPS threaded connections provide straightforward installation into compatible threaded piping systems.

Brass Body

Durable brass construction provides dependable strength and corrosion resistance in compatible service environments.

Construction Details

The valve body is manufactured from brass for dependable durability and resistance to corrosion in compatible plumbing and fluid handling applications.

The internal swing disc opens freely during forward flow, helping maintain relatively low restriction through the valve.

When flow stops or reverses, the disc closes against the seat to help prevent backflow without requiring manual operation.

How It Works

Forward Flow

Normal system flow pushes the swing disc away from the seat, allowing fluid to pass through the valve.

Reverse Flow

When forward flow decreases or reverses, the disc returns toward the seat and closes the flow path to help prevent backflow.

Why Choose a Swing Check Valve?

Low Flow Restriction

  • Disc swings away from the main flow path
  • Helps minimize pressure drop
  • Suitable for continuous forward flow
  • Simple internal mechanism
  • Useful in general fluid systems

Automatic Backflow Protection

  • No manual operator required
  • Responds automatically to flow direction
  • Helps protect pumps and piping
  • Provides one-way flow control
  • Simple mechanical operation

Typical Applications

Residential & Commercial

  • Water piping
  • General plumbing systems
  • Utility piping
  • Pump discharge lines
  • Equipment protection

Industrial Fluid Handling

  • Oil service
  • Air systems
  • General fluid transfer
  • Process support piping
  • Compatible non-corrosive media

Installation Orientation

Horizontal Installation

The valve is designed for horizontal piping installations when the flow arrow is aligned with normal system flow.

Vertical Installation

Vertical installation may be suitable when upward flow is maintained and the specific valve configuration permits proper swing-disc operation.

Willy knows his pipe sizes
Ask Willy: Need Help Selecting a Ball Valve?

Our valve, fitting, and industrial product specialists can help review your valve size, FIP connection requirements, pressure rating, handle configuration, media compatibility, and application before you order.

Email the GetPipe.com Team Visit Quick Support

Frequently Asked Questions

What type of valve is this?

This is a Midland brass swing check valve designed for automatic one-way flow control.

What material is the valve made from?

The supplied product information identifies durable brass construction.

What type of connections does it use?

The valve uses female IPS threaded connections.

How does the swing check mechanism work?

The hinged disc opens with forward flow and closes automatically when flow stops or reverses.

What sizes are available?

The supplied product information identifies sizes from 1/2" through 4".

What media can it be used with?

The supplied information identifies water, oil, air, and other compatible fluids, subject to pressure, temperature, and material limitations.

Can the valve be installed vertically?

Vertical installation may be suitable when upward flow is maintained and the manufacturer permits that orientation for the specific valve.

Does installation direction matter?

Yes. Install the valve with the flow arrow on the body pointing in the intended direction of normal system flow.

What should I verify before ordering?

Confirm valve size, IPS thread compatibility, installation orientation, intended media, operating pressure, and temperature requirements.

Important Ordering & Installation Notes

  • This listing is for Midland Brass Swing Check Valves.
  • Available sizes range from 1/2" through 4".
  • Confirm the required nominal valve size before ordering.
  • Verify female IPS thread compatibility with the intended piping system.
  • Install with the flow arrow pointing in the intended direction of system flow.
  • Horizontal installation is generally suitable for this swing-check configuration.
  • For vertical installation, maintain upward flow and verify manufacturer requirements.
  • Verify brass compatibility with the intended media.
  • Confirm system pressure and operating temperature requirements before installation.
  • Use an appropriate thread sealant where permitted.
  • Avoid excessive installation torque that could damage the brass body or threaded connections.
  • Support connected piping to prevent excessive mechanical load on the valve.
  • Check operation after installation to confirm proper forward flow and reverse-flow closure.
  • Fully isolate and depressurize the system before maintenance or replacement.
  • Follow applicable plumbing or mechanical codes and manufacturer recommendations.
View AllClose

Reviews