Midland Industries
Midland AWWA C515 Non-Rising Stem Gate Valve (FL x MJ)
- Availability:
- Allow 2-3 Days to Ship
- Weight:
- 0.00 LBS
Description
Midland AWWA C515 Non-Rising Stem Gate Valve (FL x MJ)
Midland AWWA C515 Non-Rising Stem Gate Valves (FL x MJ) are designed for dependable isolation service in municipal water distribution and utility piping systems.
Constructed from heavy-duty ductile iron, these resilient seated gate valves feature a flanged inlet, mechanical joint outlet, stainless steel non-rising stem, and a 300 PSI working pressure rating. Available in sizes from 3" through 12", they are manufactured to meet AWWA C515 requirements for reliable waterworks service.
Product Highlights
- Midland AWWA C515 resilient seated gate valve
- Flanged x Mechanical Joint (FL x MJ) end connections
- Non-rising stem (NRS) design
- 300 PSI working pressure rating
- Heavy-duty ductile iron body construction
- Stainless steel stem for corrosion resistance
- Resilient wedge for dependable shutoff
- Designed for municipal water distribution systems
- Suitable for buried and above-ground potable water applications
- Available in 3", 4", 6", 8", 10", and 12" nominal sizes
- Manufactured to AWWA C515 requirements
Technical Specifications
| Product Type | Resilient Seated Gate Valve |
|---|---|
| Brand | Midland |
| Standard | AWWA C515 |
| Body Material | Ductile Iron |
| Stem Material | Stainless Steel |
| Stem Design | Non-Rising Stem (NRS) |
| Closure Type | Resilient Wedge |
| Connection Type | Flanged x Mechanical Joint |
| Pressure Rating | 300 PSI |
| Available Sizes | 3", 4", 6", 8", 10", and 12" |
| Primary Function | On/Off Water Isolation |
| Typical Service | Municipal Water Distribution and Potable Water Systems |
Available Options
9600FJ3
Size: 3"
9600FJ4
Size: 4"
9600FJ6
Size: 6"
9600FJ8
Size: 8"
9600FJ10
Size: 10"
9600FJ12
Size: 12"
Valve Configuration
Flanged Connection
The flanged end provides a bolted connection to a compatible mating flange within the water distribution system.
Resilient Wedge Body
The internal resilient wedge moves through the valve body to provide dependable full-open or full-closed isolation.
Mechanical Joint Connection
The MJ end provides a mechanical connection to compatible waterworks piping using the appropriate joint accessories.
Construction Details
The Midland AWWA C515 gate valve uses a high-strength ductile iron body designed for long-term service in demanding municipal and commercial water systems.
A stainless steel non-rising stem provides corrosion resistance while remaining protected within the valve body during operation.
The resilient wedge provides dependable sealing performance, while the FL x MJ end configuration allows the valve to transition between flanged piping and mechanical joint waterworks connections.
Why Choose an AWWA C515 Gate Valve?
Waterworks Design
- Manufactured to AWWA C515 requirements
- Designed for municipal water distribution
- 300 PSI working pressure rating
- Resilient seated shutoff
- Ductile iron construction
Installation Flexibility
- Flanged connection on one end
- Mechanical joint connection on the other
- Suitable for buried or above-ground installations
- Multiple nominal sizes available
- Useful for water main transitions and isolation points
Non-Rising Stem Design
Compact Operation
The non-rising stem remains within the valve body during opening and closing, reducing the amount of vertical operating clearance required.
Suitable for Underground Service
The compact stem design is well suited for buried installations where above-valve clearance is limited.
FL x MJ Connection
Flanged End
The flanged side connects to a compatible mating flange using the appropriate gasket, bolts, and installation procedures.
Mechanical Joint End
The mechanical joint side connects to compatible waterworks pipe using the required gland, gasket, bolts, and related joint components.
Typical Applications
Municipal Water Systems
- Water distribution mains
- Transmission piping
- Utility service lines
- Municipal isolation points
- Potable water infrastructure
Commercial & Utility Systems
- Site water mains
- Commercial water distribution
- Underground utility piping
- Mechanical room water systems
- Infrastructure isolation valves
Flanged vs. Mechanical Joint Connections
Flanged Connection
A flanged connection uses bolted mating flanges and a gasket to create a rigid, serviceable joint in the piping system.
Mechanical Joint Connection
A mechanical joint uses a gland, gasket, and bolts to form a secure connection with compatible waterworks piping.

Our valve, fitting, and industrial product specialists can help review your valve size, FIP connection requirements, pressure rating, handle configuration, media compatibility, and application before you order.
Email the GetPipe.com Team Visit Quick SupportFrequently Asked Questions
What does FL x MJ mean?
FL x MJ indicates a flanged connection on one end and a mechanical joint connection on the other.
What standard does this valve meet?
The supplied product information identifies the valve as manufactured to AWWA C515 requirements.
What is the pressure rating?
The supplied product information lists a 300 PSI working pressure rating.
What sizes are available?
The supplied product information lists 3", 4", 6", 8", 10", and 12" nominal sizes.
What material is the valve body made from?
The supplied product information identifies heavy-duty ductile iron body construction.
What material is the stem?
The supplied product information identifies a stainless steel stem.
What does NRS mean?
NRS means non-rising stem. The stem remains within the valve body rather than extending upward as the valve opens.
Can this valve be installed underground?
Yes. The supplied product information identifies buried and above-ground potable water systems as suitable applications.
Is this valve designed for throttling?
Gate valves are generally intended for full-open or full-closed isolation service rather than routine throttling.
What are the available Midland part numbers?
The supplied part numbers are 9600FJ3, 9600FJ4, 9600FJ6, 9600FJ8, 9600FJ10, and 9600FJ12.
What should I verify before ordering?
Confirm nominal valve size, flange compatibility, mechanical joint requirements, pressure rating, installation location, piping dimensions, and project specifications before ordering.
Important Ordering & Installation Notes
- This listing is for a Midland AWWA C515 Non-Rising Stem Gate Valve with FL x MJ end connections.
- Available sizes are 3", 4", 6", 8", 10", and 12".
- Available Midland part numbers are 9600FJ3, 9600FJ4, 9600FJ6, 9600FJ8, 9600FJ10, and 9600FJ12.
- The supplied product information lists a 300 PSI working pressure rating.
- Confirm compatibility with the intended mating flange dimensions and pressure class.
- Verify all required mechanical joint accessories before installation.
- Confirm pipe outside diameter and mechanical joint compatibility.
- Use the appropriate flange gasket and bolting for the installation.
- Ensure mating piping is properly aligned before tightening flange or mechanical joint hardware.
- Do not use joint bolts to force misaligned piping into position.
- Gate valves should generally be operated fully open or fully closed rather than used for routine throttling.
- For buried installations, maintain proper access for future valve operation and maintenance.
- Verify system pressure, water service requirements, installation depth, and project specifications before placing the valve into service.
- Install according to AWWA requirements, applicable utility standards, project specifications, and manufacturer recommendations.