ABB
Load Center Plug-On Neutral Panelboard Interior – MCB Aluminum Bus
- Availability:
- Allow 2-3 Days to Ship
- Weight:
- 0.00 LBS
Description
Load Center Plug-On Neutral Panelboard Interior – MCB Aluminum Bus
Load Center Plug-On Neutral Panelboard Interiors – MCB Aluminum Bus are ABB ReliaHome P-Series load centers designed for residential electrical distribution applications requiring a main circuit breaker, plug-on neutral construction, and aluminum bus.
This product family includes 100A and 200A configurations with circuit capacities ranging from 16/32 through 40/80. Indoor NEMA 1 and outdoor NEMA 3R configurations are available depending on the selected catalog number.
Product Highlights
- ABB ReliaHome P-Series load centers
- Main Circuit Breaker (MCB) configuration
- Plug-on neutral design
- Aluminum bus construction
- Single-phase electrical configuration
- 3-wire, 120/240 VAC system
- 100A and 200A options
- 16/32, 20/40, 30/60, and 40/80 configurations
- Indoor NEMA 1 models available
- Outdoor NEMA 3R model available
- Galvanized enclosure construction
- Integrated circuit breaker mounting rails
- One-tool installation design
- Backed-out neutral screws
- Field-extendable neutral bars
- Factory-installed bonding screw on main circuit breaker models
- UL 67 certified
Technical Specifications
| Manufacturer | ABB |
|---|---|
| Product Family | ReliaHome P-Series |
| Product Type | Load Center / Panelboard Interior |
| Main Configuration | Main Circuit Breaker (MCB) |
| Neutral Design | Plug-On Neutral |
| Bus Material | Aluminum |
| Phase | Single Phase |
| Wire Configuration | 3 Wire |
| System Voltage | 120/240 VAC |
| Available Ampere Ratings | 100A, 200A |
| Available Circuit Configurations | 16/32, 20/40, 30/60, 40/80 |
| Enclosure Options | NEMA 1 Indoor, NEMA 3R Outdoor |
| Enclosure Construction | Galvanized |
| Certification | UL 67 |
| Available Catalog Numbers | PAM1610, PAM2010, PAM2010R, PAM3010, PAM3020, PAM4020 |
Construction Details
ABB ReliaHome P-Series load centers use galvanized enclosure construction with integrated circuit breaker mounting rails and a plug-on neutral design intended to simplify compatible branch breaker installation.
The standard P-Series uses aluminum bus bars and is designed for single-phase, 3-wire, 120/240 VAC residential electrical distribution.
ABB also incorporates elevated neutral bars with backed-out neutral screws, field-extendable neutral bars, and a one-tool installation approach into the ReliaHome P-Series platform.
A factory-installed bonding screw is standard on main circuit breaker ReliaHome P-Series configurations.
Available Load Center Configurations
Catalog Number & Configuration
| Catalog Number | Ampere Rating | Spaces / Circuits | Main Type | NEMA Type |
|---|---|---|---|---|
| PAM1610 | 100A | 16/32 | Main Circuit Breaker | NEMA 1 |
| PAM2010 | 100A | 20/40 | Main Circuit Breaker | NEMA 1 |
| PAM2010R | 100A | 20/40 | Main Circuit Breaker | NEMA 3R |
| PAM3010 | 100A | 30/60 | Main Circuit Breaker | NEMA 1 |
| PAM3020 | 200A | 30/60 | Main Circuit Breaker | NEMA 1 |
| PAM4020 | 200A | 40/80 | Main Circuit Breaker | NEMA 1 |
Selecting the Correct Load Center
100A | 16/32
Select PAM1610 for a 100A indoor NEMA 1 main-breaker configuration with 16 spaces and capacity for up to 32 circuits.
100A | 20/40 Indoor
Select PAM2010 for a 100A indoor NEMA 1 main-breaker configuration with 20 spaces and capacity for up to 40 circuits.
100A | 20/40 Outdoor
Select PAM2010R for a 100A outdoor NEMA 3R main-breaker configuration with 20 spaces and capacity for up to 40 circuits.
100A | 30/60
Select PAM3010 for a 100A indoor NEMA 1 main-breaker configuration with 30 spaces and capacity for up to 60 circuits.
200A | 30/60
Select PAM3020 for a 200A indoor NEMA 1 main-breaker configuration with 30 spaces and capacity for up to 60 circuits.
200A | 40/80
Select PAM4020 for a 200A indoor NEMA 1 main-breaker configuration with 40 spaces and capacity for up to 80 circuits.
Main Circuit Breaker Configuration
These PAM models use a Main Circuit Breaker (MCB) configuration. The main breaker provides the primary disconnecting and overcurrent-protection function for the compatible load center assembly.
ABB identifies main circuit breaker configurations as part of the ReliaHome P-Series offering and specifies factory-installed bonding screws on main circuit breaker models.
Confirm the required service rating, available fault current, conductor size, branch breaker requirements, and complete service-equipment configuration before installation.
Plug-On Neutral Design
Simplified Breaker Connections
The ReliaHome plug-on neutral design provides a dedicated neutral connection system for compatible plug-on neutral branch breakers.
Accessible Neutral Bars
Elevated neutral bars, backed-out neutral screws, and field-extendable neutral bars help provide easier conductor access and installation flexibility.
Aluminum Bus Construction
ABB identifies the standard ReliaHome P-Series as using aluminum bus bars. Copper bus construction is available in the separate P-Series+ family.
The bus material should be considered along with service amperage, breaker configuration, conductor requirements, and project specifications when selecting the complete load center.
NEMA 1 vs. NEMA 3R
NEMA 1 Indoor
PAM1610, PAM2010, PAM3010, PAM3020, and PAM4020 are listed here as indoor NEMA 1 configurations.
NEMA 3R Outdoor
PAM2010R is the outdoor configuration in this product group. ABB identifies outdoor ReliaHome P-Series enclosures as NEMA 3R.
120/240V Residential Distribution
Single Phase
ReliaHome P-Series load centers are designed for compatible single-phase residential electrical distribution.
3-Wire System
ABB specifies a three-wire electrical configuration for the ReliaHome P-Series.
120/240 VAC
The published system voltage for the ReliaHome P-Series is 120/240 VAC.
Installation-Friendly Features
One-Tool Installation
ABB identifies a one-tool installation approach as a standard ReliaHome P-Series design feature.
Integrated Breaker Rails
Integrated circuit breaker mounting rails provide the mounting structure for compatible ReliaHome branch circuit breakers.
Maximized Gutter Space
The ReliaHome design provides increased gutter space to improve conductor routing and working room during installation.
Common Applications
Residential Electrical Distribution
- Single-family residences
- Residential branch circuit distribution
- Electrical service equipment
- New residential construction
- Home additions
- Panel replacement projects
Service & Panel Upgrades
- 100A residential services
- 200A residential services
- Indoor NEMA 1 load center replacements
- Outdoor NEMA 3R installations
- Plug-on neutral breaker systems
- Electrical service upgrades
Spaces & Circuit Capacity
The listed configurations identify the number of standard breaker spaces and the corresponding maximum circuit capacity for each model.
- PAM1610: 16 spaces / 32 circuits
- PAM2010: 20 spaces / 40 circuits
- PAM2010R: 20 spaces / 40 circuits
- PAM3010: 30 spaces / 60 circuits
- PAM3020: 30 spaces / 60 circuits
- PAM4020: 40 spaces / 80 circuits
Confirm breaker compatibility and the approved circuit configuration for the exact load center before installation.
Installation & Selection Considerations
- Confirm that a main circuit breaker load center is required.
- Verify a single-phase, 3-wire, 120/240 VAC electrical system.
- Select the required 100A or 200A ampere rating.
- Confirm the required number of spaces and circuits.
- Verify whether the installation requires NEMA 1 indoor or NEMA 3R outdoor construction.
- Select PAM2010R for the listed outdoor NEMA 3R 100A 20/40 configuration.
- Confirm compatible plug-on neutral branch breakers.
- Verify available fault current and complete equipment ratings.
- Confirm service conductor size and terminal requirements.
- Maintain NEMA 3R enclosure integrity on outdoor installations.
- Maintain applicable electrical working clearances.
- Follow manufacturer terminal torque requirements.
- De-energize equipment before installation or service.
- Verify absence of voltage before working on electrical equipment.
- Installation should be performed by qualified electrical personnel.
- Follow current ABB instructions and applicable electrical codes.
Product Documents
Review the ABB ReliaHome Load Centers datasheet for P-Series construction details, plug-on neutral design, aluminum bus construction, main circuit breaker configurations, NEMA 1 and NEMA 3R enclosure options, electrical specifications, certification information, and manufacturer guidance.
Need Help Selecting a Load Center?
Our electrical and industrial product specialists can help review your service amperage, number of spaces, circuit requirements, indoor or outdoor enclosure needs, main breaker configuration, and compatible branch breakers before you order.
Frequently Asked Questions
What product family are these load centers part of?
These models are part of ABB's ReliaHome P-Series load center family.
Are these main breaker or main lug load centers?
These PAM models are listed as main circuit breaker configurations.
What bus material is used?
ABB specifies aluminum bus construction for the standard ReliaHome P-Series.
What voltage are these load centers designed for?
The ReliaHome P-Series is designed for single-phase, 3-wire, 120/240 VAC systems.
What is PAM1610?
PAM1610 is the 100A, 16/32, NEMA 1 main-breaker configuration.
What is PAM2010?
PAM2010 is the 100A, 20/40, NEMA 1 main-breaker configuration.
What is PAM2010R?
PAM2010R is the 100A, 20/40 outdoor NEMA 3R main-breaker configuration.
What is PAM3010?
PAM3010 is the 100A, 30/60, NEMA 1 main-breaker configuration.
What is PAM3020?
PAM3020 is the 200A, 30/60, NEMA 1 main-breaker configuration.
What is PAM4020?
PAM4020 is the 200A, 40/80, NEMA 1 main-breaker configuration.
Do these load centers use plug-on neutral?
Yes. ABB identifies plug-on neutral as a standard ReliaHome P-Series feature.
Is the bonding screw factory installed?
Yes. ABB states that a factory-installed bonding screw is standard on ReliaHome main circuit breaker configurations.
Are ReliaHome P-Series load centers UL certified?
Yes. ABB identifies the P-Series as UL 67 certified.
Where can I find ABB's product information?
The ABB ReliaHome Load Centers Datasheet PDF is linked in the Product Documents section above.
Important Ordering & Installation Notes
- Product: Load Center Plug-On Neutral Panelboard Interior – MCB Aluminum Bus.
- PAM1610: 100A | 16/32 | NEMA 1.
- PAM2010: 100A | 20/40 | NEMA 1.
- PAM2010R: 100A | 20/40 | NEMA 3R.
- PAM3010: 100A | 30/60 | NEMA 1.
- PAM3020: 200A | 30/60 | NEMA 1.
- PAM4020: 200A | 40/80 | NEMA 1.
- Main configuration: Main Circuit Breaker.
- Neutral design: Plug-On Neutral.
- Bus material: Aluminum.
- Phase: Single phase.
- Wire configuration: 3 wire.
- Voltage: 120/240 VAC.
- Indoor models: NEMA 1.
- Outdoor PAM2010R model: NEMA 3R.
- Factory-installed bonding screw is standard on main breaker configurations.
- UL 67 certified.
- Confirm ampere rating, circuit capacity, enclosure type, and breaker compatibility before ordering.
- De-energize equipment before installation or service.
- Installation should be performed by qualified electrical personnel.
- Follow current ABB instructions and applicable electrical codes.