Spears

CPVC-29 Solvent Cement

(No reviews yet) Write a Review
SKU:
CPVC29
Availability:
Usually Ships Same Day
Weight:
0.00 LBS
*Images are for visual reference only.
  • CPVC-29 Solvent Cement
  • CPVC-29 Solvent Cement Spec Sheet
$39.70 - $133.20

Represents the combined quantity sold of all the sizes under this product SKU.
Sold:
Frequently bought together:

Description

CPVC-29 Solvent Cement

Spears® Manufacturing CPVC-29 Solvent Cement is an industrial-grade, extra-heavy-bodied CPVC solvent cement with a slow-setting formulation developed for large-diameter CPVC and PVC piping systems requiring chemical resistance, high gap-filling properties, and additional assembly time.

CPVC-29 is suitable for all classes and schedules of compatible CPVC and PVC pipe and fittings with interference-fit connections through 24" nominal pipe size. Its versatile formulation is particularly useful for chemical piping, large fabricated fittings, and fume and duct applications.

Product Highlights

  • Industrial grade
  • Slow-setting formula
  • Extra-heavy-bodied cement
  • Available in gray or orange
  • Suitable for CPVC and PVC systems
  • Provides high gap-filling properties
  • Designed for chemically resistant piping applications
  • All classes and schedules through 24" nominal pipe size

Technical Specifications

Product Type Low VOC CPVC Solvent Cement
Manufacturer Spears® Manufacturing
Product Series CPVC-29
Available Colors Gray or Orange
Resin CPVC
Body Extra-Heavy Body
Relative Set Slow
Specific Gravity 0.986 ± 0.01
Minimum Viscosity 1600 cP @ 73 ± 2°F
Material Compatibility CPVC & PVC
Maximum Nominal Pipe Size Through 24"
Pipe Compatibility All Classes & Schedules of Compatible CPVC or PVC
ASTM Standard ASTM F493
Maximum VOC Emissions ≤490 g/L
Shelf Life 2 Years from Date Stamped on Container
Certification UL 2818 GREENGUARD GOLD

Chemically Resistant Industrial Joining

CPVC-29 is specially formulated for compatible CPVC and PVC systems requiring chemical resistance to demanding services such as caustics, hypochlorite solutions, mineral acids, aggressive water, and aqueous salt solutions.

This industrial-grade formulation makes CPVC-29 a strong choice for chemical-processing and other demanding piping installations where material compatibility, chemical resistance, and properly assembled solvent-cement joints are important.

Extra-Heavy Body & High Gap Fill

The extra-heavy-bodied formulation provides high gap-filling properties for large-diameter piping systems, fabricated fittings, and other compatible connections where a substantial cement body is desirable during assembly.

Proper interference fit and surface preparation remain essential, and CPVC-29 should always be applied according to current Spears® installation instructions and the requirements of the selected CPVC or PVC piping system.

Large-Diameter CPVC & PVC Systems

CPVC-29 is suitable for all classes and schedules of compatible CPVC and PVC through 24" nominal pipe size, providing broad coverage for large industrial piping and fabricated fitting applications.

The slow-setting formulation provides additional working time for applying cement, inserting the pipe, and properly aligning larger components before the completed connection begins to set.

Fume, Duct & Chemical Applications

CPVC-29 is recommended for compatible chemical piping, large fabricated fittings, and fume and duct fittings, making it a versatile industrial solvent cement for applications where both PVC and CPVC components may be encountered.

Always verify material compatibility, nominal pipe size, schedule, chemical service, operating temperature, system pressure, and installation requirements before selecting CPVC-29 for the intended piping system.

Installation & Selection Considerations

  • Check the cement before use.
  • Keep the container tightly sealed.
  • Confirm CPVC or PVC compatibility.
  • Verify chemical and operating conditions before installation.
  • Follow Spears® joining and cure requirements before placing the system in service.
Willy knows his pipe sizes
Ask Willy: Need CPVC-29 Solvent Cement Information?

Review the supplied Spears® documents for additional CPVC-29 specifications, CPVC and PVC compatibility, chemical-resistant applications, large-diameter joining requirements, product standards, handling guidance, and solvent-cement installation information before use.

Need Help Selecting CPVC Solvent Cement?

Our product specialists can help review your CPVC or PVC material, pipe size, schedule, chemical service, operating conditions, large-diameter fitting requirements, and installation needs before you order.

Frequently Asked Questions

What colors is CPVC-29 available in?

Spears® CPVC-29 is available in gray or orange, allowing the appropriate version to be selected for the intended industrial piping installation.

How fast does CPVC-29 set?

CPVC-29 has a slow relative set, providing additional working time for applying the cement and assembling larger compatible CPVC or PVC connections.

Can CPVC-29 be used with PVC?

Yes. CPVC-29 is recommended for compatible PVC as well as CPVC piping systems, particularly in industrial and chemical applications.

Is CPVC-29 an extra-heavy-bodied cement?

Yes. CPVC-29 is an extra-heavy-bodied industrial solvent cement formulated to provide high gap-filling properties for demanding piping and fabricated fitting applications.

What size pipe can CPVC-29 be used with?

CPVC-29 is suitable for all classes and schedules of compatible CPVC or PVC pipe and fittings with interference-fit connections through 24" nominal pipe size.

Is CPVC-29 intended for chemical applications?

Yes. CPVC-29 is formulated for compatible systems requiring chemical resistance to services including caustics, hypochlorite solutions, mineral acids, aggressive water, and aqueous salt solutions.

Where is CPVC-29 commonly used?

CPVC-29 is particularly useful for large-diameter industrial piping, chemical applications, fabricated fittings, and compatible CPVC or PVC fume and duct fittings.

What is the shelf life of CPVC-29?

CPVC-29 has a specified shelf life of two years from the date stamped on the bottom of the container when properly stored and kept tightly sealed between uses.

Important Ordering & Installation Notes

  • Check the container date before use.
  • Do not add thinner to thickened cement.
  • Verify CPVC or PVC compatibility before joining.
  • Confirm chemical and operating conditions before installation.
  • Allow large solvent-cement connections to properly cure before system operation.
View AllClose