Lesso America
ABS DWV Cleanout Wye (HUB x HUB x FIPT)
- SKU:
- LN604
- Availability:
- Usually Ships Same Day
- Weight:
- 0.00 LBS
Description
ABS DWV Cleanout Wye (HUB x HUB x FIPT)
ABS DWV Cleanout Wyes provide a smooth wye-style branch connection with a female threaded cleanout opening for inspection, maintenance, and drain-cleaning access.
Featuring two hub connections on the main run and a female iron pipe thread (FIPT) connection on the cleanout branch, this fitting is designed for non-pressure ABS drain, waste, and vent systems. The wye configuration provides a gradual branch transition while the threaded cleanout opening allows installation of a compatible cleanout plug or accessory for future service access. Manufactured for ABS DWV service, it meets recognized standards including ASTM D2661, CSA B181.1, and NSF Standard 14.
Product Highlights
- ABS DWV cleanout wye
- HUB x HUB x FIPT connection configuration
- Two hub connections form the main piping run
- Female iron pipe thread cleanout branch
- Provides convenient cleanout and inspection access
- Accepts a compatible threaded cleanout plug or accessory
- Wye-style branch provides a gradual access path
- Useful for rodding, snaking, and maintenance access
- Hub connections accept compatible ABS DWV pipe
- Designed for solvent-cement installation at hub connections
- Suitable for drain, waste, and vent systems
- Suitable for sewer and general drainage applications
- Non-pressure fitting
- Maximum operating temperature of 140°F
- Not intended for compressed air or gas service
- Not intended for pressure testing
- Manufactured from virgin ABS polymers
- Complies with ASTM D2661
- Certified to CSA B181.1
- Meets NSF Standard 14 requirements
Technical Specifications
| Product Type | ABS DWV Cleanout Wye |
|---|---|
| Material | ABS |
| Connection Type | Hub x Hub x Female Iron Pipe Thread (FIPT) |
| Main Run Connections | Hub x Hub |
| Cleanout Connection | Female Iron Pipe Thread (FIPT) |
| Joint Method | Solvent Cement at Hub Connections; Threaded Cleanout Branch |
| System Type | Drain, Waste, and Vent (DWV) |
| Pressure Service | Non-Pressure |
| Maximum Operating Temperature | 140°F |
| Primary Function | Provide Threaded Cleanout Access to an ABS DWV Piping Run |
| Referenced Standards | ASTM D3965, ASTM D2661, CSA B181.1, NSF Standard 14 |
| Typical Applications | Sanitary Drainage, Waste Lines, Sewer Piping, General Drainage, Cleanout Access, Inspection, and Maintenance |
Connection Configuration
Main Run Hubs
The two hub connections form the primary ABS DWV piping run and accept compatible pipe for solvent-cement installation.
Female Threaded Cleanout
The cleanout branch features female iron pipe threads for installation of a compatible threaded plug or cleanout accessory.
Cleanout Wye Design
The cleanout wye combines a gradual wye-style branch path with a threaded service opening.
The angled branch can provide a more direct path into the drainage line for appropriate cleaning equipment, while the FIPT connection allows the opening to be closed with a compatible threaded plug during normal system operation.
This design helps provide future maintenance access without requiring the main piping run to be cut or disassembled.
Why Choose an ABS DWV Cleanout Wye?
Maintenance Access
- Provides a dedicated cleanout opening
- Supports inspection and drain maintenance
- Useful for rodding or snaking access
- Threaded branch accepts a compatible plug
- Helps avoid cutting into the piping system for future access
ABS DWV Benefits
- Lightweight construction
- Easy handling and installation
- Suitable for non-pressure drainage systems
- Compatible with ABS DWV piping systems
- Designed for long-term sanitary drainage service
Typical Applications
Drainage Systems
- Sanitary drain lines
- Waste piping
- Sewer piping
- General building drainage
- ABS DWV piping runs
Service & Maintenance
- Cleanout access points
- Drain inspection
- Rodding access
- Snaking access
- Routine maintenance
Standards & Compliance
- ASTM D3965: ABS material requirements for pipe extrusion and molded fittings
- ASTM D2661: Schedule 40 ABS drain, waste, and vent pipe and fittings
- CSA B181.1: ABS drain, waste, and vent pipe, fittings, and accessories
- NSF Standard 14: Plastic piping system components and related materials
Installation
Verify both hub sizes and the FIPT cleanout size before installation. Position the fitting so the threaded cleanout opening will remain accessible after surrounding construction is complete.
Cut mating ABS pipe ends square and remove burrs. Clean and prepare the pipe and hub surfaces according to accepted ABS solvent-cement installation procedures.
Dry-fit the assembly before applying solvent cement to confirm main-run alignment and cleanout branch orientation.
Apply compatible ABS solvent cement as required and fully seat each pipe into its corresponding hub while maintaining proper alignment.
Install a compatible threaded cleanout plug or accessory in the FIPT branch according to manufacturer recommendations. Allow completed solvent-cement joints to cure before placing the system into service.

Our piping specialists can help review your main-run size, cleanout thread size, fitting orientation, and ABS DWV compatibility before you order.
Email the GetPipe.com Team Visit Quick SupportFrequently Asked Questions
What is an ABS DWV cleanout wye used for?
It provides a threaded access point to an ABS DWV piping run for inspection, maintenance, rodding, snaking, and other appropriate drain-cleaning procedures.
What does HUB x HUB x FIPT mean?
It means the fitting has two hub connections for the main run and one female iron pipe threaded connection for the cleanout branch.
What is the purpose of the FIPT connection?
The female threaded branch allows installation of a compatible male-threaded cleanout plug or accessory.
Why use a wye for cleanout access?
The angled wye branch provides a gradual access path into the drainage run, which can be useful when inserting appropriate drain-cleaning equipment.
Does the cleanout plug come with the fitting?
The supplied product description identifies the branch as FIPT but does not state that a plug is included. Verify the specific listing contents before ordering.
Should the cleanout remain accessible?
Yes. The fitting should be positioned so the threaded opening can be reached for future inspection and maintenance.
Do the hub connections require solvent cement?
Yes. The hub connections are intended for compatible ABS solvent-cement installation.
Is this fitting intended for pressure systems?
No. This fitting is intended for non-pressure drain, waste, vent, sewer, and general drainage applications.
Can it be used for compressed air or gas?
No. The supplied product information states that ABS DWV fittings are not intended for transporting compressed air or gas.
What is the maximum operating temperature?
The supplied product information specifies use in applications where operating temperatures do not exceed 140°F.
What should I verify before ordering?
Confirm both hub sizes, the FIPT cleanout size, cleanout accessibility, fitting orientation, and compatibility with the intended non-pressure ABS DWV system.
Important Ordering & Installation Notes
- This listing is for an ABS DWV Cleanout Wye with HUB x HUB x FIPT connections.
- Verify both nominal hub sizes before ordering.
- Verify the female threaded cleanout size before ordering.
- The cleanout branch uses female iron pipe threads.
- The supplied description does not confirm that a cleanout plug is included.
- Use a compatible male-threaded cleanout plug or accessory where required.
- Position the cleanout so it remains accessible after installation.
- Provide sufficient clearance for future plug removal and drain-cleaning equipment.
- Confirm main-run and cleanout branch orientation before installation.
- Dry-fit the complete assembly before applying solvent cement.
- Hub connections are intended for compatible ABS solvent-cement installation.
- This fitting is intended for non-pressure DWV, sewer, and general drainage applications.
- Do not use for transporting compressed air or gas.
- Do not use for pressure testing.
- Maximum operating temperature is 140°F.
- Cut pipe square and remove burrs before assembly.
- Clean and prepare all mating surfaces before solvent-cement installation.
- Fully seat each ABS pipe into its corresponding hub.
- Use only compatible threaded components at the FIPT cleanout connection.
- Maintain proper main-run and cleanout alignment while the joints set.
- Allow completed joints to cure according to the solvent cement manufacturer's recommendations before service.
- Protect the fitting from incompatible chemicals, fire-stopping materials, thread sealants, and other aggressive agents that may damage ABS compounds.
- Consult manufacturer documentation for complete dimensions and installation requirements.
- Follow applicable plumbing codes and manufacturer installation recommendations.