ABB

60A Non-Fusible AC Disconnect Switch

(No reviews yet) Write a Review
SKU:
TFN60RPRE
Availability:
Allow 2-3 Days to Ship
Weight:
2.50 LBS
*Images are for visual reference only.
  • 60A Non-Fusible AC Disconnect Switch
  • 60A Non-Fusible AC Disconnect Switch
  • 60A Non-Fusible AC Disconnect Switch
  • ABB Logo
$17.55

Represents the combined quantity sold of all the sizes under this product SKU.
Sold:
Frequently bought together:

Description

60A Non-Fusible AC Disconnect Switch

ABB 60A Non-Fusible AC Disconnect Switch provides a convenient outdoor disconnecting means for compatible air-conditioning, refrigeration, HVAC, and motor applications. Store SKU TFN60RPRE uses a pull-out disconnect design housed in a NEMA 3R enclosure for compatible outdoor installations.

This disconnect is rated 60A at 240V AC and does not contain fuses. It provides equipment isolation while required overcurrent protection is supplied elsewhere in the electrical system.

Product Highlights

  • ABB AC disconnect switch
  • Store SKU TFN60RPRE
  • ABB base catalog reference TFN60R
  • 60A ampere rating
  • 240V AC voltage rating
  • Non-fusible design
  • Pull-out disconnect operation
  • Up to 10 HP application rating
  • NEMA Type 3R enclosure
  • Suitable for compatible outdoor installations
  • Cu/Al conductor compatibility
  • #14 through #3 conductor range
  • Compact equipment-disconnect design
  • cULus listed

Technical Specifications

Manufacturer ABB
Store SKU TFN60RPRE
ABB Catalog Reference TFN60R
Product Type Puller-Type AC Disconnect
Ampere Rating 60A
Voltage Rating 240V AC
Fusing Non-Fusible / No Fuse
Enclosure NEMA Type 3R
Operation Pull-Out Disconnect
Motor Application Up to 10 HP
Conductor Material Copper / Aluminum
Wire Range #14 - #3 Cu/Al
Height 7.50"
Depth 2.50"
Weight 2.502 lb
Listing cULus Listed

Construction Details

The TFN60R-series disconnect uses a compact pull-out AC disconnect configuration designed to provide a readily accessible means of disconnecting compatible equipment from its electrical supply.

The enclosure is rated NEMA Type 3R, making the disconnect suitable for compatible outdoor applications when installed in accordance with manufacturer instructions and applicable electrical requirements.

The unit accepts compatible copper or aluminum conductors from #14 through #3.

Electrical Ratings

60A Rating

The disconnect is rated for a maximum current of 60 amps in the listed configuration.

240V AC

ABB specifies a 240V AC voltage rating for the TFN60R disconnect.

Non-Fusible

This is a non-fusible disconnect switch. Required circuit overcurrent protection must be provided separately as applicable.

Pull-Out Disconnect Design

Simple Equipment Isolation

The pull-out mechanism provides a straightforward method of disconnecting compatible HVAC or other equipment for inspection, maintenance, and service.

Visible Disconnect Status

The removable pull-out mechanism provides a clear physical disconnect arrangement for compatible equipment servicing applications.

NEMA 3R Outdoor Enclosure

The disconnect is supplied in a NEMA Type 3R enclosure for compatible outdoor installations.

NEMA 3R construction is commonly used where equipment requires protection from outdoor weather exposure such as falling rain and sleet while maintaining the proper installation orientation and enclosure integrity.

Conduit entries, mounting, drainage, and field modifications should be completed in accordance with ABB instructions so the enclosure's intended protection is maintained.

HVAC & Motor Applications

Air Conditioning & Refrigeration

  • Air-conditioning equipment
  • Outdoor condensing units
  • Heat pump equipment
  • Refrigeration systems
  • HVAC service disconnect applications

Motor & Equipment Isolation

  • Compatible motor loads
  • Equipment service disconnects
  • Residential outdoor equipment
  • Light commercial equipment
  • Maintenance isolation applications

Conductor Compatibility

ABB specifies a conductor range of #14 through #3 Cu/Al for the TFN60R disconnect.

  • Copper conductors supported within the approved range
  • Aluminum conductors supported within the approved range
  • Maximum and minimum conductor size must be observed
  • Conductors should be prepared and terminated according to ABB requirements
  • Use the manufacturer-specified terminal torque for the exact installation

Non-Fusible vs. Fusible Disconnects

Non-Fusible Design

The TFN60R-series disconnect provides switching and equipment isolation without integral fuses.

Overcurrent Protection

Because the disconnect is non-fusible, required overcurrent protection must be provided by the appropriate upstream circuit breaker, fuse, or other approved protective device.

Installation & Selection Considerations

  • Confirm store SKU TFN60RPRE before ordering.
  • Verify that a 60A non-fusible disconnect is appropriate for the equipment.
  • Confirm that the electrical system does not exceed the 240V AC rating.
  • Verify equipment horsepower and disconnect requirements.
  • Confirm that NEMA 3R construction is appropriate for the installation environment.
  • Provide required overcurrent protection separately.
  • Verify conductor material and size are within the approved range.
  • Maintain enclosure integrity during conduit and cable installation.
  • Follow manufacturer terminal torque requirements.
  • Do not exceed the ratings of the disconnect or connected equipment.
  • Maintain applicable electrical working clearances.
  • De-energize all circuits before installation or service.
  • Verify absence of voltage before working on electrical equipment.
  • Installation and service should be performed by qualified electrical personnel.
  • Follow current ABB instructions and applicable electrical codes.

Product Documents

Review the ABB TFN60R Product Details for the manufacturer's ampere rating, voltage rating, non-fusible configuration, NEMA enclosure type, conductor range, dimensions, listing information, and additional product specifications.

Need Help Selecting an AC Disconnect?

Our electrical and industrial product specialists can help review your equipment amperage, voltage, horsepower, conductor requirements, enclosure location, and overcurrent-protection requirements before you order.

Frequently Asked Questions

What is the SKU for this disconnect?

The GetPipe.com SKU is TFN60RPRE. The supplied ABB product-details document identifies the base disconnect catalog number as TFN60R.

What is the ampere rating?

The disconnect is rated 60A.

What is the voltage rating?

ABB specifies a 240V AC rating.

Is this disconnect fusible?

No. This is a non-fusible AC disconnect. Required overcurrent protection must be provided separately.

What type of enclosure does it use?

The disconnect uses a NEMA Type 3R enclosure for compatible outdoor installations.

What conductor sizes are accepted?

ABB specifies a wire range of #14 through #3 Cu/Al.

Can copper conductors be used?

Yes. The published conductor range permits compatible copper conductors.

Can aluminum conductors be used?

Yes. The published conductor range also permits compatible aluminum conductors.

Is this commonly used for HVAC equipment?

Yes. Pull-out AC disconnects of this configuration are designed for compatible air-conditioning, refrigeration, heat pump, and related equipment-disconnect applications.

What is the height of the enclosure?

ABB lists the enclosure height as 7.50 inches.

What is the enclosure depth?

ABB lists the enclosure depth as 2.50 inches.

Is the disconnect listed?

Yes. ABB identifies the TFN60R as cULus Listed.

Where can I review the ABB specifications?

The ABB TFN60R Product Details PDF is linked in the Product Documents section above.

Important Ordering & Installation Notes

  • Product: 60A Non-Fusible AC Disconnect Switch.
  • Store SKU: TFN60RPRE.
  • ABB product-document catalog reference: TFN60R.
  • Ampere rating: 60A.
  • Voltage rating: 240V AC.
  • Fusing: Non-fusible / no fuse.
  • Operation: Pull-out AC disconnect.
  • Enclosure: NEMA Type 3R.
  • Wire range: #14 - #3 Cu/Al.
  • Height: 7.50".
  • Depth: 2.50".
  • Weight: 2.502 lb.
  • Listing: cULus Listed.
  • Provide required overcurrent protection separately.
  • Verify voltage, ampere, horsepower, conductor, and equipment requirements before ordering.
  • Maintain NEMA 3R enclosure integrity during installation.
  • De-energize equipment before installation or service.
  • Installation should be performed by qualified electrical personnel.
  • Follow current ABB instructions and applicable electrical codes.