ABB

200A Main Breaker Panelboard Enclosure - NEMA 1

(No reviews yet) Write a Review
SKU:
THQMV200NRE
Availability:
Allow 2-3 Days to Ship
Weight:
18.27 LBS
*Images are for visual reference only.
  • 200A Main Breaker Panelboard Enclosure - NEMA 1
  • 200A Main Breaker Panelboard Enclosure - NEMA 1
  • 200A Main Breaker Panelboard Enclosure - NEMA 1
  • ABB Logo
$1,024.44

Frequently bought together:

Description

200A Main Breaker Panelboard Enclosure - NEMA 1

ABB THQMV200NRE 200A Main Breaker Panelboard Enclosure is designed for compatible electrical distribution applications requiring a 200-amp main breaker enclosure with a NEMA 1 indoor enclosure rating.

Catalog number THQMV200NRE should be matched to the exact compatible panelboard, main breaker configuration, bus arrangement, conductor requirements, and complete electrical assembly before ordering or installation.

Product Highlights

  • ABB main breaker panelboard enclosure
  • Catalog number THQMV200NRE
  • 200A configuration
  • NEMA 1 enclosure
  • Designed for compatible indoor electrical distribution applications
  • Main breaker panelboard enclosure configuration
  • Single-SKU product
  • Verify exact equipment compatibility before ordering

Technical Specifications

Manufacturer ABB
Catalog Number THQMV200NRE
Product Type Main Breaker Panelboard Enclosure
Ampere Rating 200A
Enclosure Rating NEMA 1
Installation Environment Indoor
Primary Application Compatible Electrical Distribution / Panelboard Equipment

Enclosure & Application Details

The THQMV200NRE provides a NEMA 1 enclosure configuration for compatible indoor panelboard and electrical distribution applications.

NEMA 1 enclosures are intended for compatible indoor installations. The enclosure should be installed only where its environmental rating is appropriate for the location.

Confirm the exact panelboard, main breaker arrangement, mounting configuration, and equipment compatibility before installation.

Electrical Configuration

200A Configuration

THQMV200NRE is the 200A configuration supplied for compatible main breaker panelboard applications.

NEMA 1 Enclosure

The enclosure carries a NEMA 1 designation for compatible indoor electrical installations.

Single Model Selection Guide

Ampere Rating Catalog Number Enclosure Application
200A THQMV200NRE NEMA 1 Main Breaker Panelboard Enclosure

NEMA 1 Indoor Enclosure

The NEMA 1 configuration is intended for compatible indoor locations where the electrical equipment does not require an outdoor or weather-resistant enclosure rating.

Verify the installation environment before ordering. Do not use a NEMA 1 enclosure where a higher environmental enclosure rating is required.

Common Applications

Panelboard Applications

  • Compatible indoor panelboard installations
  • Main breaker panelboard configurations
  • Electrical distribution equipment
  • Commercial electrical systems
  • Replacement enclosure applications

Indoor Distribution Applications

  • Dry indoor electrical locations
  • Electrical rooms
  • Building distribution systems
  • Compatible service equipment configurations
  • Approved ABB panelboard installations

Installation & Selection Considerations

  • Confirm catalog number THQMV200NRE before ordering.
  • Verify that a 200A main breaker panelboard enclosure is required.
  • Confirm that a NEMA 1 indoor enclosure is appropriate for the installation environment.
  • Verify compatibility with the exact ABB panelboard and main breaker configuration.
  • Confirm the bus arrangement and mounting requirements.
  • Verify system voltage and complete panelboard electrical ratings before installation.
  • Confirm conductor material and wire size requirements.
  • Verify terminal and conductor requirements before installation.
  • Follow ABB terminal torque and equipment installation requirements.
  • Do not substitute an enclosure based only on ampere rating or physical dimensions.
  • Do not use a NEMA 1 enclosure where an outdoor or higher environmental rating is required.
  • Maintain all required electrical working clearances.
  • De-energize equipment before installation or service.
  • Verify absence of voltage before working inside electrical equipment.
  • Installation and service should be performed by qualified electrical personnel.
  • Follow current ABB instructions and applicable local and national electrical codes.

Product Documents

Review the ABB THQMV200NRE Product Details for manufacturer specifications, enclosure information, electrical ratings, dimensions, compatibility information, and additional product details.

Need Help Selecting a Panelboard Enclosure?

Our electrical and industrial product specialists can help review your panelboard, main breaker rating, enclosure requirements, bus configuration, conductor requirements, and equipment compatibility before you order.

Frequently Asked Questions

What is the catalog number?

The catalog number is THQMV200NRE.

What is the ampere rating?

THQMV200NRE is the 200A configuration.

What enclosure rating does THQMV200NRE have?

THQMV200NRE uses a NEMA 1 enclosure configuration.

Is this enclosure intended for indoor use?

Yes. NEMA 1 is intended for compatible indoor electrical installations.

Is THQMV200NRE a circuit breaker?

No. It is a main breaker panelboard enclosure configuration and should be matched to compatible electrical equipment.

Can I select this enclosure based only on the 200A rating?

No. Confirm the exact panelboard, main breaker arrangement, bus configuration, mounting requirements, and enclosure compatibility before ordering.

Can this NEMA 1 enclosure be installed outdoors?

Do not use a NEMA 1 enclosure where an outdoor or weather-resistant enclosure rating is required.

Where can I review the ABB product documentation?

The ABB THQMV200NRE Product Details PDF is linked in the Product Documents section above.

Important Ordering & Installation Notes

  • Product: 200A Main Breaker Panelboard Enclosure - NEMA 1.
  • Catalog number: THQMV200NRE.
  • Manufacturer: ABB.
  • Ampere rating: 200A.
  • Enclosure rating: NEMA 1.
  • Installation environment: Indoor.
  • Product type: Main Breaker Panelboard Enclosure.
  • Confirm the exact ABB panelboard and main breaker configuration before ordering.
  • Verify that THQMV200NRE is approved for the intended panelboard and bus arrangement.
  • Confirm that a 200A main breaker enclosure configuration is required.
  • Verify that a NEMA 1 indoor enclosure is appropriate for the installation environment.
  • Do not use a NEMA 1 enclosure where an outdoor, weather-resistant, or higher environmental enclosure rating is required.
  • Do not select the enclosure based only on amperage or physical appearance.
  • Verify system voltage and complete electrical equipment ratings before installation.
  • Confirm conductor material, wire size, terminal requirements, and mounting arrangement.
  • Follow ABB terminal torque and installation requirements.
  • Do not exceed the ampere, voltage, or electrical ratings of the enclosure, panelboard, main breaker, or connected equipment.
  • Maintain required barriers, covers, and electrical working clearances after installation.
  • De-energize equipment before installing, removing, or servicing the enclosure or associated electrical equipment.
  • Verify absence of voltage before working inside electrical equipment.
  • Installation and service should be performed by qualified electrical personnel.
  • Follow current ABB installation instructions, equipment labeling, and all applicable local and national electrical codes.