Midland Industries
Midland Copper Solder Joint Tee - C x C x C
- Availability:
- Usually Ships in 5-7 Business Days
- Weight:
- 0.00 LBS
Description
Midland Copper Solder Joint Tee - C x C x C
Midland Copper Solder Joint Tees provide a three-way connection for compatible copper tubing systems. These copper fittings feature C x C x C solder-joint / sweat connections and are available in both equal-size and reducing configurations for branching copper piping systems.
Choose from equal tees for same-size branch connections or reducing tee configurations when the branch or run requires a different nominal copper tube size.
Product Highlights
- Midland copper tee fitting
- C x C x C connection configuration
- Cup-style solder-joint / sweat connections
- Copper construction
- Three-way piping connection
- Equal and reducing configurations available
- Designed for compatible copper tubing systems
- 25 configurations on one listing
- Nominal connection sizes through 3"
Available Configurations
| Part Number | Size | Configuration |
|---|---|---|
| 77338 | 1/8" | Equal Tee |
| 77339 | 1/4" | Equal Tee |
| 77340 | 3/8" | Equal Tee |
| 77341 | 3/8" x 1/2" | Reducing Tee |
| 77342 | 3/8" x 1/4" | Reducing Tee |
| 77343 | 1/2" | Equal Tee |
| 77344 | 1/2" x 1" | Reducing Tee |
| 77345 | 1/2" x 3/4" | Reducing Tee |
| 77346 | 1/2" x 3/8" | Reducing Tee |
| 77347 | 1/2" x 1/4" | Reducing Tee |
| 77349 | 3/4" | Equal Tee |
| 77353 | 3/4" x 1" | Reducing Tee |
| 77402 | 1" | Equal Tee |
| 77403 | 1" x 1-1/4" | Reducing Tee |
| 77404 | 1" x 3/4" | Reducing Tee |
| 77405 | 1" x 1/2" | Reducing Tee |
| 77406 | 1-1/4" | Equal Tee |
| 77407 | 1-1/4" x 1-1/2" | Reducing Tee |
| 77408 | 1-1/4" x 1" | Reducing Tee |
| 77410 | 1-1/2" | Equal Tee |
| 77412 | 1/8" x 1/4" | Reducing Tee |
| 77413 | 2" | Equal Tee |
| 77414 | 2-1/2" | Equal Tee |
| 77415 | 1/4" x 3/8" | Reducing Tee |
| 77416 | 3" | Equal Tee |
Technical Specifications
| Manufacturer | Midland |
|---|---|
| Product Type | Copper Solder Joint Tee |
| Material | Copper |
| Connection Type | C x C x C |
| Connection Style | Cup / Sweat |
| Joining Method | Solder Joint |
| Configuration | Three-Way Tee |
| Available Styles | Equal and Reducing Configurations |
| Maximum Listed Nominal Size | 3" |
What Is a Copper Tee?
A copper tee creates a three-way connection in a copper tubing system. It is commonly used to add a branch connection to an existing or new piping run.
- Two connections form the primary run.
- The third connection forms the branch.
- Equal tees are used when the connections are the same nominal size.
- Reducing configurations allow different nominal tube sizes to be incorporated into the tee connection.
Equal vs. Reducing Tee Configurations
Equal Tee
An equal tee is intended for a three-way connection using the same nominal tube size. These variants are identified by a single nominal size, such as 1/2", 1", or 2".
Reducing Tee
A reducing configuration incorporates different nominal connection sizes, allowing the piping system to branch or transition between compatible copper tube sizes.
Available Equal Tee Sizes
- 1/8"
- 1/4"
- 3/8"
- 1/2"
- 3/4"
- 1"
- 1-1/4"
- 1-1/2"
- 2"
- 2-1/2"
- 3"
Why Use a Copper Tee?
Create a Branch
Add a third copper tube connection to a primary piping run.
Maintain Copper Construction
Provides a copper fitting for compatible copper tubing installations.
Multiple Configurations
Choose equal or reducing configurations based on the required piping layout.
Solder Joint Installation
- Verify all required copper tube connection sizes before installation.
- Cut tubing squarely.
- Remove internal and external burrs.
- Clean the copper tube ends and fitting cups thoroughly.
- Apply joining materials appropriate for the piping application.
- Insert the tubing fully into the fitting sockets.
- Confirm the branch is correctly oriented before heating.
- Use proper soldering and heating procedures.
- Allow completed joints to cool naturally.
- Inspect and test the completed piping system as appropriate.
Common Applications
Plumbing & Mechanical
- Copper water piping
- Heating systems
- Cooling systems
- Mechanical rooms
- Equipment connections
- Branch piping
Commercial & Industrial
- Facility piping
- Process piping
- Industrial equipment connections
- Maintenance and repair
- Copper distribution systems
- Piping modifications
How to Select the Correct Tee
- Step 1: Determine the nominal copper tube size of the primary run.
- Step 2: Determine the required branch connection size.
- Step 3: Choose an equal or reducing configuration as required.
- Step 4: Match the complete size configuration to the correct Midland part number.
- Step 5: Verify C x C x C solder-joint connections are appropriate for the application.
Complete Variant Reference
| Part Number | Size |
|---|---|
| 77338 | 1/8" |
| 77339 | 1/4" |
| 77340 | 3/8" |
| 77341 | 3/8" x 1/2" |
| 77342 | 3/8" x 1/4" |
| 77343 | 1/2" |
| 77344 | 1/2" x 1" |
| 77345 | 1/2" x 3/4" |
| 77346 | 1/2" x 3/8" |
| 77347 | 1/2" x 1/4" |
| 77349 | 3/4" |
| 77353 | 3/4" x 1" |
| 77402 | 1" |
| 77403 | 1" x 1-1/4" |
| 77404 | 1" x 3/4" |
| 77405 | 1" x 1/2" |
| 77406 | 1-1/4" |
| 77407 | 1-1/4" x 1-1/2" |
| 77408 | 1-1/4" x 1" |
| 77410 | 1-1/2" |
| 77412 | 1/8" x 1/4" |
| 77413 | 2" |
| 77414 | 2-1/2" |
| 77415 | 1/4" x 3/8" |
| 77416 | 3" |
Installation Guidance
- Verify every connection size before installation, particularly on reducing configurations.
- Dry-fit the piping layout before soldering where practical.
- Make sure the tee branch points in the required direction.
- Clean all mating copper surfaces before joining.
- Insert the tubing properly into each fitting cup.
- Use soldering materials appropriate for the piping application.
- Support the connected piping to minimize stress on the fitting.
- Use appropriate additional support for larger copper tubing.
- Pressure-test the completed piping system according to applicable requirements.

Our pipe, fitting, and industrial product specialists can help review your copper tube sizes, equal or reducing tee configuration, C x C x C connections, branch requirements, solder-joint installation, piping layout, and application before you order.
Email the GetPipe.com Team Visit Quick SupportFrequently Asked Questions
What is a copper tee used for?
A copper tee creates a three-way connection, allowing a branch to be added to a copper tubing system.
What does C x C x C mean?
C x C x C indicates cup-style solder-joint connections used with compatible copper tubing.
What is an equal tee?
An equal tee uses the same nominal tube size for its connections. Equal-size variants in this listing are identified by a single size.
Are reducing configurations available?
Yes. This listing includes both equal-size tees and configurations with different nominal connection sizes.
What sizes are available?
The listed configurations include nominal connection sizes from 1/8" through 3".
How are these copper tees installed?
They use solder-joint / sweat connections with compatible copper tubing.
Important Ordering Notes
- This listing contains 25 Midland copper tee configurations.
- Equal and reducing configurations are included.
- Verify the complete connection-size configuration before ordering.
- Reducing configurations may contain different nominal connection sizes.
- Select the Midland part number matching the required piping layout.