Midland Industries
Lead-Free Curb Stop Ball Valve - FIP to FIP
- Availability:
- Allow 2-3 Days to Ship
- Weight:
- 0.00 LBS
Description
Lead-Free Curb Stop Ball Valve - FIP to FIP
Lead-Free Curb Stop Ball Valves - FIP to FIP provide dependable shutoff control for compatible water service and plumbing applications. The female iron pipe threaded connections on both ends allow the valve to connect directly to compatible male-threaded piping or fittings.
The curb stop ball valve design provides quarter-turn operation for quick opening and closing, while the lead-free brass construction is intended for compatible potable-water and water-service applications where lead-free components are required.
Product Highlights
- Lead-free brass construction
- Curb stop ball valve design
- Female iron pipe thread x female iron pipe thread
- Quarter-turn shutoff operation
- Designed for compatible water-service applications
- Compact in-line valve configuration
- Suitable for compatible residential, commercial, municipal, and utility piping systems
Technical Specifications
| Product Type | Curb Stop Ball Valve |
|---|---|
| Material | Lead-Free Brass |
| Connection Style | FIP x FIP |
| Valve Type | Ball Valve |
| Operation | Quarter Turn |
| Primary Function | Shutoff / Isolation of Compatible Water Service Lines |
Construction Details
The valve features a lead-free brass body with female iron pipe threaded connections on both ends for direct installation between compatible male-threaded piping components.
Inside the valve body, a rotating ball controls flow through the passage. Turning the operating mechanism approximately one quarter turn moves the ball between open and closed positions.
The compact curb stop configuration is useful in water-service installations where a durable in-line isolation valve is needed for maintenance, service, or shutoff control.
Connection Configuration
Female Iron Pipe Thread - End 1
The first female threaded end accepts a compatible male-threaded pipe, nipple, adapter, or other fitting.
Female Iron Pipe Thread - End 2
The opposite female threaded end connects to another compatible male-threaded piping component to complete the in-line valve installation.
How the Curb Stop Ball Valve Works
Open Position
When the ball passage is aligned with the valve body, water can flow through the valve.
Closed Position
Rotating the ball approximately 90 degrees moves the solid portion of the ball across the flow path to shut off the line.
Lead-Free Brass Construction
Lead-free brass is commonly selected for compatible potable-water and water-service applications where lead-content requirements apply.
Always confirm that the selected valve meets the applicable plumbing code, certification, pressure, temperature, and installation requirements for the specific water system.
Curb Stop Applications
A curb stop is commonly used as an isolation valve in a water service line, allowing downstream piping or equipment to be shut off for maintenance, repair, or service.
The compact ball valve design provides positive quarter-turn operation and can be installed in compatible service-line, utility, plumbing, or equipment connections.
Common Applications
Water Service & Plumbing
- Water service lines
- Residential plumbing
- Commercial plumbing
- Utility water connections
- Meter and service assemblies
- Maintenance shutoff points
Municipal & General Service
- Municipal water systems
- Service-line isolation
- Compatible potable-water systems
- Building water connections
- Equipment isolation
- General water-distribution systems
Selecting the Correct Curb Stop Ball Valve
| Selection Point | What to Confirm |
|---|---|
| Valve Size | Match the valve size to the piping system and service-line requirements. |
| Connection Type | Confirm FIP x FIP connections are appropriate for both mating components. |
| Lead-Free Requirement | Verify the valve meets applicable lead-free requirements for the intended water application. |
| Operating Conditions | Confirm pressure and temperature requirements for the water system. |
| Installation Requirements | Confirm applicable plumbing code, accessibility, valve orientation, and service requirements. |
Installation & Selection Considerations
- Confirm the valve size and FIP x FIP connection requirements before ordering.
- Inspect mating male threads for damage or contamination before installation.
- Use a thread-sealing method appropriate for potable-water service and brass threaded connections.
- Install the valve so the operating mechanism remains accessible for service.
- Verify applicable lead-free, pressure, temperature, plumbing-code, and system requirements before use.

Our pipe, valve, and water-service product specialists can help review your valve size, FIP connections, lead-free requirements, water-service application, and installation needs before you order.
Email the GetPipe.com Team Visit Quick SupportFrequently Asked Questions
What is a Lead-Free Curb Stop Ball Valve?
It is a quarter-turn shutoff valve designed for compatible water-service applications and manufactured with lead-free brass construction.
What does FIP to FIP mean?
FIP to FIP means the valve has female iron pipe threaded connections on both ends.
How does the ball valve operate?
The internal ball rotates approximately 90 degrees between open and closed positions, providing quarter-turn shutoff operation.
Where is a curb stop commonly installed?
Curb stops are commonly installed in water service lines where an isolation point is needed for service, maintenance, or shutoff control.
Why is lead-free brass important?
Lead-free brass is commonly specified for potable-water and water-service applications where applicable lead-content requirements must be met.
What connects to the FIP ends?
Each female threaded end connects to a compatible male-threaded pipe, nipple, adapter, or fitting.
Should thread sealant be used?
Use a thread-sealing method appropriate for brass threaded connections, potable-water service when applicable, and the requirements of the piping system.
What should I confirm before ordering?
Confirm the valve size, FIP x FIP connections, lead-free requirements, pressure, temperature, water-service application, and applicable installation requirements.
Important Ordering & Installation Notes
- Lead-free brass curb stop ball valve.
- Connection configuration is FIP x FIP.
- Confirm the correct valve size and mating male-threaded connections before ordering.
- Use an appropriate thread-sealing method and install the valve for accessible operation.
- Verify lead-free, pressure, temperature, plumbing-code, and application requirements before use.