Dixon

B7RMP-R250200 - Clamp Reducing Tee

(No reviews yet) Write a Review
SKU:
B7RMP-R250200
Availability:
Usually Ships Same Day
Weight:
1.21 LBS
*Images are for visual reference only.
$103.91

Represents the combined quantity sold of all the sizes under this product SKU.
Sold:
Frequently bought together:

Description

B7RMP-R250200 Clamp Reducing Tee - 2-1/2" x 2" 316L Stainless Steel

Dixon B7RMP-R250200 is a 2-1/2" x 2" sanitary clamp reducing tee manufactured from 316L stainless steel for hygienic and process piping applications.

The fitting provides a 2-1/2" sanitary clamp main run with a reduced 2" branch connection. This configuration allows a smaller sanitary process line to branch from a larger main line while maintaining removable clamp connections for cleaning, inspection, maintenance, and equipment service.

Product Highlights

  • Genuine Dixon sanitary clamp reducing tee
  • Manufacturer part number B7RMP-R250200
  • 2-1/2" x 2" tube O.D. configuration
  • 316L stainless steel construction
  • 2-1/2" main run with 2" reduced branch
  • Three sanitary clamp connections
  • Designed for hygienic and sanitary process piping
  • Published dimension A: 2.84"
  • Published dimension B: 2.81"
  • Older published overall run length: 5.688"
  • 304 stainless steel equivalent: B7RMP-G250200
  • Part of Dixon's B7RMP Clamp Reducing Tee family

Technical Specifications

Brand Dixon
Manufacturer Part Number B7RMP-R250200
Product Type Clamp Reducing Tee
Series B7RMP
Tube O.D. 2-1/2" x 2"
Main Run Size 2-1/2"
Branch Size 2"
Material 316L Stainless Steel
Connection Type Sanitary Clamp
Number of Connections 3
Configuration Reducing Tee
Published Dimension A 2.84"
Published Dimension B 2.81"
Older Published Overall Run Length 5.688"
304 Stainless Steel Equivalent B7RMP-G250200
Application Hygienic process piping branch and size-reduction connections

Reducing Tee Configuration

The B7RMP-R250200 combines a straight 2-1/2" sanitary run with a reduced 2" sanitary branch.

This configuration allows a 2" process line to branch from a larger 2-1/2" main line without requiring a separate reducing adapter at the branch connection.

All three ports use sanitary clamp-style connections, allowing the fitting to be assembled and removed using compatible sanitary ferrules, gaskets, and clamps.

316L Stainless Steel Construction

The B7RMP-R250200 is manufactured from 316L stainless steel, a corrosion-resistant material commonly used in sanitary and hygienic process piping systems.

316L stainless steel is frequently selected for compatible food, beverage, dairy, pharmaceutical, and industrial process applications where corrosion resistance and hygienic construction are important.

Material suitability should always be confirmed for the actual process fluid, concentration, operating temperature, cleaning chemistry, sanitation procedures, and environmental conditions.

Sanitary Clamp Connections

2-1/2" Main Run

  • Two 2-1/2" sanitary clamp connections
  • Maintains the larger line size through the tee
  • Removable clamp-style joints
  • Designed for compatible sanitary tubing systems
  • Allows access during cleaning and maintenance

2" Reduced Branch

  • One 2" sanitary clamp connection
  • Provides a reduced branch from the 2-1/2" main run
  • Useful for smaller process-line takeoffs
  • Provides an integrated size transition
  • Eliminates the need for a separate reducer at the branch

Published Dimensions

Tube O.D. 2-1/2" x 2"
Current Catalog Dimension A 2.84"
Current Catalog Dimension B 2.81"
Older Published Overall Run 5.688"
Older Published Center-to-End 2.844"
Older Published Branch Height 2.812"

Dixon's current sanitary/hygienic fittings literature lists B7RMP-R250200 with dimensions of 2.84" and 2.81". Older Dixon dimensional literature provides the same geometry at greater precision, listing a 5.688" overall run length, 2.844" center-to-end, and 2.812" branch height.

304 vs. 316L Version

B7RMP-R250200

  • 2-1/2" x 2" tube O.D.
  • 316L stainless steel
  • Dixon R-series material configuration
  • For systems requiring compatible 316L stainless steel construction

B7RMP-G250200

  • 2-1/2" x 2" tube O.D.
  • 304 stainless steel
  • Dixon G-series material configuration
  • Corresponding 304 stainless steel version

Typical Applications

Food & Beverage

  • Food processing systems
  • Beverage production
  • Dairy processing
  • Breweries
  • Wineries and distilleries

Hygienic Process Systems

  • Compatible pharmaceutical process piping
  • Sanitary fluid-transfer systems
  • Process equipment connections
  • Reduced branch takeoffs
  • Compatible industrial hygienic systems

Sanitary Fitting Selection

Dixon identifies B7RMP-R250200 as a 2-1/2" x 2" tube O.D. reducing tee. The 2-1/2" dimension applies to the straight main run, while the 2" dimension applies to the reduced branch.

Do not automatically substitute conventional nominal pipe sizing for sanitary tube O.D. Confirm the dimensions of the existing sanitary tubing and mating clamp connections before ordering.

Also confirm that 316L stainless steel is the required material for the process media, cleaning chemistry, and sanitation conditions.

Gasket & Clamp Selection

Sanitary Gaskets

  • Two 2-1/2" gaskets for the main-run connections
  • One 2" gasket for the reduced branch
  • Select gasket material for the process media
  • Verify operating-temperature compatibility
  • Verify compatibility with cleaning chemicals

Sanitary Clamps

  • Use correctly sized clamps for each connection
  • Verify 2-1/2" and 2" mating ferrule compatibility
  • Inspect clamps before use
  • Align mating ferrule faces before tightening
  • Do not use clamps to correct piping misalignment

Standards & Sanitary Applications

Dixon's product resources for B7RMP-R250200 reference 3-A Sanitary Standard 63-04 under Certificate Authorization Number 621.

Application-specific sanitary, regulatory, material, documentation, and installation requirements should still be confirmed for the complete process system before placing the fitting into service.

Installation

Confirm the 2-1/2" main-run size, 2" reduced branch size, 316L stainless steel construction, and sanitary clamp configuration before installation.

Inspect all three clamp faces for contamination, scratches, dents, deformation, or other damage that could interfere with proper gasket sealing.

Install compatible sanitary gaskets between each mating ferrule face. Select gasket material according to the process fluid, operating temperature, cleaning chemistry, sanitation procedures, and other system requirements.

Align all piping and equipment before installing the clamps. Do not use the fitting or clamps to force misaligned tubing into position.

Properly support connected piping so external loads are not transferred unnecessarily to the reducing tee or its sanitary joints.

After assembly, inspect all three connections and verify leak-free operation under appropriate process conditions before returning the system to service.

Willy knows his Dixon sanitary fittings
Ask Willy: Need Help Selecting a Dixon Clamp Reducing Tee?

Our team can help confirm your main-line size, branch size, stainless steel grade, clamp size, gasket material, and mating sanitary components before you order.

Email the GetPipe.com Team Visit Quick Support

Frequently Asked Questions

What size is Dixon B7RMP-R250200?

B7RMP-R250200 is a 2-1/2" x 2" tube O.D. sanitary clamp reducing tee.

Which size is the main run?

The straight main run is 2-1/2" tube O.D.

What size is the reduced branch?

The reduced branch connection is 2" tube O.D.

What material is B7RMP-R250200?

Dixon identifies B7RMP-R250200 as 316L stainless steel.

How many sanitary clamp connections are provided?

The fitting has three clamp connections: two 2-1/2" connections on the main run and one 2" reduced branch connection.

What are the current published dimensions?

Dixon lists dimension A as 2.84" and dimension B as 2.81".

What is the older overall run length?

Older Dixon dimensional literature lists a 5.688" overall run length.

What is the 304 stainless steel equivalent?

B7RMP-G250200 is the corresponding 2-1/2" x 2" 304 stainless steel clamp reducing tee.

Are clamps and gaskets included?

Do not assume clamps or gaskets are included unless specifically stated in the GetPipe.com offering. They are normally selected separately according to connection size and process requirements.

Is the 2-1/2" x 2" size based on tube O.D.?

Yes. Dixon identifies this fitting using sanitary tube outside diameter.

What is a clamp reducing tee used for?

It allows a smaller sanitary branch line to connect to a larger main process line while retaining removable hygienic clamp connections.

What should I verify before ordering B7RMP-R250200?

Confirm the B7RMP-R250200 part number, 2-1/2" main-run tube O.D., 2" branch tube O.D., 316L stainless steel requirement, fitting dimensions, gasket materials, and clamp compatibility.

Important Ordering & Installation Notes

  • This listing is for Dixon part number B7RMP-R250200.
  • Product type is a sanitary clamp reducing tee.
  • Main run tube O.D. is 2-1/2".
  • Reduced branch tube O.D. is 2".
  • Material is 316L stainless steel.
  • Three sanitary clamp connections are provided.
  • Current Dixon literature lists dimension A as 2.84".
  • Current Dixon literature lists dimension B as 2.81".
  • Older Dixon literature lists a 5.688" overall run length.
  • B7RMP-G250200 is the corresponding 304 stainless steel version.
  • Verify sanitary tube O.D. before ordering.
  • Do not confuse sanitary tube O.D. with conventional nominal pipe size.
  • Confirm 316L compatibility with process media and cleaning chemistry.
  • Select 2-1/2" and 2" sanitary gaskets separately unless specifically included.
  • Select corresponding sanitary clamps separately unless specifically included.
  • Verify gasket material for chemical and temperature compatibility.
  • Inspect all three clamp faces before assembly.
  • Do not use damaged or distorted sealing surfaces.
  • Properly support connected piping and equipment.
  • Do not use the fitting or clamps to force misaligned tubing into position.
  • Verify complete system pressure and temperature limitations before operation.
  • Follow applicable sanitary installation, cleaning, inspection, and process requirements.
View AllClose

Reviews