Description
2-Pole Bolt-On Circuit Breaker
ABB TEY 2-Pole Bolt-On Circuit Breakers are compact lighting panel circuit breakers designed for compatible grounded electrical distribution systems. The TEY platform uses a one-inch-wide-per-pole bolt-on construction and is available here in ampere ratings from 20A through 50A.
All six models in this product group use a non-interchangeable LI trip configuration with fixed long-time and instantaneous functions. ABB lists these two-pole TEY breakers for 120V AC, 120/240V AC, 240V AC, and 277V AC system-voltage applications. :contentReference[oaicite:0]{index=0}
Product Highlights
- ABB TEY / Q-Line bolt-on circuit breakers
- 2-pole configuration
- 20A, 25A, 30A, 35A, 40A, and 50A options
- One-inch-wide-per-pole compact design
- Bolt-on mounting
- Non-interchangeable trip style
- LI trip function
- Fixed long-time and instantaneous functions
- Suitable for reverse feed
- Quick-make / quick-break mechanism
- Common trip-bar construction
- Easy-to-spot trip indication
- HACR and HID markings
- Compatible with auxiliary contact and shunt-trip accessories where applicable
Technical Specifications
| Manufacturer | ABB |
|---|---|
| Product Line | TEY / Q-Line |
| Product Type | Lighting Panel Circuit Breaker |
| Mounting | Bolt-On |
| Number of Poles | 2 |
| Available Ampere Ratings | 20A, 25A, 30A, 35A, 40A, 50A |
| System Voltages | 120V AC, 120/240V AC, 240V AC, 277V AC |
| 120V AC Interrupting Rating | 65 kAIC |
| 120/240V AC Interrupting Rating | 65 kAIC |
| 240V AC Interrupting Rating | 65 kAIC |
| 277V AC Interrupting Rating | 14 kAIC |
| Trip Style | Non-Interchangeable |
| Trip Function | LI |
| Long Time | Fixed |
| Instantaneous | Fixed |
| Continuous Current Rated | Standard |
| Reverse Feed | Suitable |
| Wire Range - Cu / Al | 14-8 / 12-8 |
| Special Markings | HACR, HID |
| CSA File | LR57114 |
| Available Catalog Numbers | TEY220, TEY225, TEY230, TEY235, TEY240, TEY250 |
Construction Details
ABB's TEY is a compact, one-inch-wide-per-pole bolt-on circuit breaker designed for compatible grounded 480Y/277V AC systems. ABB also offers a bolt-on mounting-base accessory for approved lug-to-lug applications. :contentReference[oaicite:1]{index=1}
The TEY platform features quick-make / quick-break mechanisms, common trip bars, and visible trip indication. ABB offers the TEY family in one-, two-, and three-pole versions, with auxiliary-contact and shunt-trip accessories available for compatible configurations. :contentReference[oaicite:2]{index=2}
All six breakers listed on this page are two-pole models with fixed, non-interchangeable LI trip configurations.
Available Circuit Breakers
Catalog Number & Ampere Rating
| Catalog Number | Ampere Rating | Poles | Mounting |
|---|---|---|---|
| TEY220 | 20A | 2 | Bolt-On |
| TEY225 | 25A | 2 | Bolt-On |
| TEY230 | 30A | 2 | Bolt-On |
| TEY235 | 35A | 2 | Bolt-On |
| TEY240 | 40A | 2 | Bolt-On |
| TEY250 | 50A | 2 | Bolt-On |
Selecting the Correct Breaker
20A
Select TEY220 for the 20A two-pole configuration.
25A
Select TEY225 for the 25A two-pole configuration.
30A
Select TEY230 for the 30A two-pole configuration.
35A
Select TEY235 for the 35A two-pole configuration.
40A
Select TEY240 for the 40A two-pole configuration.
50A
Select TEY250 for the 50A two-pole configuration.
Electrical Ratings
120V / 120-240V / 240V AC
ABB lists a 65 kAIC interrupting rating at 120V AC, 120/240V AC, and 240V AC for the two-pole TEY models in the supplied combined product details. :contentReference[oaicite:3]{index=3}
277V AC
ABB lists a 14 kAIC interrupting rating at 277V AC for these two-pole TEY breakers. :contentReference[oaicite:4]{index=4}
Trip & Protection Features
LI Trip Function
These breakers use an LI trip function with fixed long-time and instantaneous characteristics.
Common Trip Bar
ABB identifies common trip-bar construction as a standard TEY family feature. :contentReference[oaicite:5]{index=5}
Reverse Feed Suitable
ABB lists these two-pole TEY models as suitable for reverse-feed applications when used in an approved compatible configuration. :contentReference[oaicite:6]{index=6}
Conductor Compatibility
The supplied ABB product details list the following conductor ranges for these TEY two-pole breakers:
- Copper: 14-8
- Aluminum: 12-8
Confirm conductor material, size, preparation, and terminal torque requirements against the exact ABB installation information before termination.
Special Markings & Classification
HACR & HID
ABB lists HACR and HID special markings for these TEY breakers. :contentReference[oaicite:7]{index=7}
CSA Classification
The supplied ABB product details identify CSA File LR57114 for the two-pole TEY models. :contentReference[oaicite:8]{index=8}
Common Applications
Lighting Panelboards
- Compatible lighting panelboards
- Commercial electrical distribution
- Industrial lighting distribution
- Institutional electrical systems
- Branch circuit protection
Maintenance & Replacement
- Compatible TEY breaker replacement
- Panelboard maintenance
- Electrical distribution servicing
- Approved bolt-on applications
- Compatible lug-to-lug applications with appropriate accessories
Installation & Selection Considerations
- Confirm the required ampere rating before ordering.
- Verify that a two-pole TEY bolt-on breaker is compatible with the exact panelboard or electrical equipment.
- Confirm system voltage before installation.
- Verify that available fault current does not exceed the applicable interrupting rating.
- Confirm conductor material and size.
- Follow ABB terminal torque requirements.
- Verify bolt-on mounting and bus compatibility.
- Do not exceed the electrical ratings of the breaker or connected equipment.
- Maintain applicable electrical working clearances.
- De-energize equipment before installation or service.
- Verify absence of voltage before working on electrical equipment.
- Installation should be performed by qualified electrical personnel.
- Follow current ABB instructions and applicable electrical codes.
Product Documents
Review the ABB combined TEY breaker product details for catalog-specific amperage, voltage ratings, interrupting ratings, trip configuration, conductor ranges, special markings, classifications, and manufacturer product information.
Need Help Selecting a Circuit Breaker?
Our electrical and industrial product specialists can help review your panelboard, ampere rating, system voltage, available fault current, mounting configuration, conductor requirements, and breaker compatibility before you order.
Frequently Asked Questions
How many poles do these breakers have?
All six breakers in this product group are two-pole TEY bolt-on circuit breakers.
What amperages are available?
Available ratings are 20A, 25A, 30A, 35A, 40A, and 50A.
What is TEY220?
TEY220 is the 20A two-pole bolt-on model.
What is TEY225?
TEY225 is the 25A two-pole bolt-on model.
What is TEY230?
TEY230 is the 30A two-pole bolt-on model.
What is TEY235?
TEY235 is the 35A two-pole bolt-on model.
What is TEY240?
TEY240 is the 40A two-pole bolt-on model.
What is TEY250?
TEY250 is the 50A two-pole bolt-on model.
What system voltages are listed?
ABB lists 120V AC, 120/240V AC, 240V AC, and 277V AC for these two-pole TEY breakers. :contentReference[oaicite:9]{index=9}
What is the interrupting rating?
The supplied ABB details list 65 kAIC at 120V AC, 120/240V AC, and 240V AC, and 14 kAIC at 277V AC. :contentReference[oaicite:10]{index=10}
Are these suitable for reverse feed?
Yes. ABB identifies the listed two-pole TEY breakers as suitable for reverse feed. :contentReference[oaicite:11]{index=11}
What trip style is used?
These breakers use a non-interchangeable LI trip configuration with fixed long-time and instantaneous functions.
Where can I review the exact ABB details?
The ABB Combined TEY Breaker Product Details PDF is linked in the Product Documents section above.
Important Ordering & Installation Notes
- Product: 2-Pole Bolt-On Circuit Breaker.
- TEY220: 20A.
- TEY225: 25A.
- TEY230: 30A.
- TEY235: 35A.
- TEY240: 40A.
- TEY250: 50A.
- Product line: ABB TEY / Q-Line.
- Number of poles: 2.
- Mounting: Bolt-On.
- Trip style: Non-Interchangeable.
- Trip function: LI.
- System voltages: 120V AC, 120/240V AC, 240V AC, 277V AC.
- 120V AC interrupting rating: 65 kAIC.
- 120/240V AC interrupting rating: 65 kAIC.
- 240V AC interrupting rating: 65 kAIC.
- 277V AC interrupting rating: 14 kAIC.
- Suitable for reverse feed: Yes.
- Special markings: HACR, HID.
- CSA File: LR57114.
- Confirm exact equipment compatibility before ordering.
- Verify conductor size, system voltage, and fault-current requirements before installation.
- De-energize equipment before installation or service.
- Installation should be performed by qualified electrical personnel.
- Follow current ABB instructions and applicable electrical codes.