Dixon
D4BM4 - DF-Series Pneumatic Male Threaded Plug
- SKU:
- D4BM4
- Availability:
- Usually Ships Within 24 Hours
- Weight:
- 0.16 LBS
*Images are for visual reference only.
Description
Details
Compatibility & Interchange Data
- Foster 3, 4, 5 and 6 Series
- Parker 30 - Series Automatic Interchange & Parker 20-Series Manual Interchange
- Hansen 3000, 4000, 5000 and 6000 & Hansen 1000, 400 and 500
Construction
- Machined components are manufactured using solid bar stock.
- Steel componentry is plated using ROHS Compliant Trivalent Chrome.
How It Works
- To disconnect, begin by holding the hose on the nipple side with three of your fingers, leaving your thumb and index finger free.
- Grab the sleeve with your thumb and index finger and begin to pull the sleeve towards the palm of your hand.
- After pulling the sleeve, the nipple will move out of the coupler slightly. Continue to hold the hose and coupler sleeve until all air is fully exhausted.
- After the line is fully exhausted, you are able to safely separate the nipple from the coupler.After the line is fully exhausted, you are able to safely separate the nipple from the coupler.
Safety Notes
It is important to be safe when installing quick disconnect couplings into a pneumatic circuit. Never install a pneumatic coupling directly into an air tool, use a piece of hose that is at least 18" long, between the tool and the coupling, to prevent damage to the coupling. To protect the operator, safety devices, such as a safety check valve and safety cable should be installed in case there is a hose or coupling failure.
Specifications
- Rated pressure when connected with Brass D-Series Automatic Couplers: 500 PSI (35 bar) Maximum Working and 14,000 PSI (965 bar) Burst
- Rated pressure when connected with Steel F-Series Manual Couplers: 500 PSI (35 bar) Maximum Working and 15,500 PSI (1,070 bar) Burst
WARNING: This product contains lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm.