PVC-25 Aqua Blue Wet-N-Dry Solvent Cement
Spears® Manufacturing PVC-25 Aqua Blue Wet-N-Dry Solvent Cement is a very fast-setting, medium-bodied PVC solvent cement specially formulated for joining compatible PVC pipe and fittings in wet conditions and applications where quick pressurization is important.
The Aqua Blue Wet-N-Dry formulation is designed for irrigation, plumbing, and pool & spa applications, with compatibility for all classes and schedules through 6" interference fit and Schedule 80 PVC through 4", while the aqua blue color gradually fades toward clear when exposed to sunlight.
Product Highlights
- Aqua blue color
- Medium-bodied consistency
- Very fast-setting formula
- Wet-N-Dry PVC formulation
- Designed for quick pressurization
- Ideal for irrigation, plumbing, pool & spa
- All classes and schedules through 6" interference fit
- Schedule 80 PVC applications through 4" interference fit
Technical Specifications
| Product Type | Wet-N-Dry PVC Solvent Cement |
|---|---|
| Manufacturer | Spears® Manufacturing |
| Product Series | PVC-25 |
| Color | Aqua Blue - Fades Toward Clear in Sunlight |
| Resin | PVC |
| Body | Medium Body |
| Relative Set | Very Fast |
| Specific Gravity | 0.925 ± 0.04 |
| Minimum Viscosity | 500 cP @ 73 ± 2°F |
| General Maximum Size | Through 6" Interference Fit |
| Schedule 80 Maximum Size | Through 4" Interference Fit |
| Primerless Use | Non-Pressure Systems Where Local Code Permits |
| ASTM Standard | ASTM D2564 |
| Maximum VOC Emissions | 425 g/L |
| Shelf Life | 3 Years from Date Stamped on Container |
Wet-N-Dry PVC Joining
PVC-25 is specifically formulated for wet conditions and quick pressurization, providing a specialized solvent-cement option for compatible PVC installations where moisture or limited installation time can make conventional joining conditions more challenging.
The medium-bodied consistency and very fast relative set are designed to support properly prepared interference-fit connections through 6" for all compatible classes and schedules, including Schedule 80 PVC applications through 4" diameter.
Irrigation, Plumbing & Pool Applications
PVC-25 is designed for compatible irrigation, plumbing, pool, and spa piping applications, making it particularly useful for repair and installation environments where wet conditions and the need for quick pressurization are important considerations.
Always confirm the PVC pipe size, schedule, fitting configuration, system pressure, service conditions, and applicable Spears® joining requirements before selecting PVC-25 and placing the completed piping system into service.
Primerless Non-Pressure Use
PVC-25 can be used without a separate primer on qualifying non-pressure PVC piping systems where local code permits, providing a simplified joining option when the specific installation meets the applicable Spears® and code requirements.
Applications that require primer should follow the complete specified preparation and joining procedure, including proper surface preparation, cement application, joint assembly, set time, and cure time before testing or pressurizing the system.
Aqua Blue Appearance
The aqua blue formulation provides a clearly visible appearance during application, helping installers identify cement coverage around properly assembled PVC pipe and fitting connections while completing the solvent-cement joining process.
The aqua blue color is designed to fade toward clear when exposed to sunlight, so a change in the visible color of the cured cement during outdoor service is a normal characteristic of the PVC-25 formulation.
Installation & Selection Considerations
- Check the cement before use.
- Keep the container tightly sealed.
- Confirm pipe size and schedule compatibility.
- Verify primerless use is permitted for non-pressure service.
- Follow Spears® joining and cure requirements before pressurizing the system.

Review the supplied Spears® documents for additional solvent-cement information, PVC joining guidance, product selection details, application requirements, and technical information before completing your installation.
Need Help Selecting Wet-N-Dry PVC Solvent Cement?
Our PVC product specialists can help review your pipe size, schedule, wet-condition installation, irrigation or pool application, primer requirements, pressurization needs, and service conditions before you order.
Frequently Asked Questions
What color is PVC-25 cement?
PVC-25 is supplied in an aqua blue formulation that provides visible cement coverage during installation and gradually fades toward clear when exposed to sunlight.
How fast does PVC-25 set?
Spears® identifies PVC-25 as a very fast-setting PVC solvent cement, making it particularly useful for compatible applications where wet conditions and quick pressurization are important.
What is PVC-25 designed for?
PVC-25 is formulated for wet conditions and quick pressurization and is designed for compatible irrigation, plumbing, pool, and spa PVC piping applications.
What size PVC can PVC-25 be used with?
PVC-25 is suitable for compatible all-class and all-schedule PVC interference-fit connections through 6" diameter, with Schedule 80 applications through 4" diameter.
Can PVC-25 be used with Schedule 80 PVC?
Yes. PVC-25 is suitable for compatible Schedule 80 PVC interference-fit pipe and fitting connections through 4" diameter when installed according to the applicable joining requirements.
Can PVC-25 be used without primer?
Yes, on qualifying non-pressure PVC systems where local code permits primerless installation, but the requirements for the specific piping system and application should always be confirmed before joining.
Is PVC-25 intended for wet conditions?
Yes. Wet-condition installation is one of the primary characteristics of PVC-25, which is specifically formulated for wet environments and applications where quick pressurization may be required.
What is the shelf life of PVC-25?
PVC-25 has a specified shelf life of three years from the date stamped on the bottom of the container when properly stored and tightly sealed between uses.
Important Ordering & Installation Notes
- Check the container date before use.
- Do not add thinner to thickened cement.
- Verify the PVC pipe size and schedule before joining.
- Confirm primerless use is permitted for the installation.
- Follow required cure times before testing or pressurizing the completed system.