Description
SDR35 Gasketed Cap
The SDR35 Gasketed Cap is designed to close the end of compatible SDR35 PVC sewer and drainage piping. It provides an end closure for sewer piping installations where a cap is required to terminate a line.
Manufactured by Tigre DuraPlastic, these PVC caps are available in 4", 6", 8", 10", and 12" nominal sizes. They are part of Tigre's SDR35 gasketed fitting family and are manufactured for compatible sewer and drainage applications. Confirm the cap's mating connection requirements before ordering.
Product Highlights
- SDR35 gasketed fitting family
- Cap configuration for sewer pipe ends
- Designed to close compatible SDR35 piping
- Available in 4", 6", 8", 10", and 12" sizes
- Suitable for compatible PVC sewer and drainage systems
- PVC construction
- Injection-molded fitting size range
- Manufactured from virgin PVC compound
- PVC cell classification 12454 or 13343
- Injection-molded PVC compound certified to ASTM D1784
- Manufactured to applicable ASTM D3034, ASTM F1336, and CSA B182.2 requirements
- SDR35 product classification
- Manufacturer part numbers available for each size
- Manufacturer drawing dimensions provided for all five sizes
- Part of Tigre's USA-made SDR35 fitting program
- Connection compatibility should be confirmed before installation
Available Sizes & Part Numbers
Select the appropriate nominal cap size for the intended SDR35 sewer piping system. The unit weights below are provided for individual fittings.
| Nominal Size | Part Number | SKU | Unit Weight |
|---|---|---|---|
| 4" | 35-1623 | 100029246 | 0.463 lb |
| 6" | 35-1624 | 100029247 | 1.202 lb |
| 8" | 35-1625 | 100029245 | 2.296 lb |
| 10" | 35-83 | 300003461 | 4.720 lb |
| 12" | 35-84 | 300003519 | 8.300 lb |
Technical Specifications
| Brand | Tigre DuraPlastic |
|---|---|
| Product Type | SDR35 Gasketed Cap |
| Manufacturer Drawing Designation | Cap |
| Product Family | SDR35 Gasketed Fittings |
| Application | End closure for compatible SDR35 sewer and drainage piping |
| Available Nominal Sizes | 4", 6", 8", 10", and 12" |
| SDR Classification | SDR35 |
| Material | PVC |
| Construction | Injection Molded |
| PVC Compound | Virgin PVC Compound |
| PVC Cell Classification | 12454 or 13343 |
| PVC Material Standard | ASTM D1784 |
| Manufacturing Standards | ASTM D3034, ASTM F1336, and CSA B182.2, as applicable |
| Connection Configuration | Confirm mating connection requirements with manufacturer |
| Gasket Standards | ASTM F477 or ASTM F913 for applicable gasketed connections |
| Gasketed Joint Standard | ASTM D3212 for applicable gasketed joints |
| Gasketed Joint Testing | Applicable gasketed joints are tested for internal pressure (exfiltration) and vacuum (infiltration), including joint misalignment and 5% top-load deflection. |
| Certification | Third-party NSF tested, certified, and listed to applicable ASTM D3034, ASTM F1336, and CSA B182.2 requirements, where applicable |
| Country of Manufacture | USA |
Manufacturer Technical Drawing Dimensions
The following measurements are taken from Tigre's Cap technical drawing. Dimensions A, B, and C correspond to the labeled measurement locations in the manufacturer's illustration. All dimensions are in inches.
| Part Number | Size | A | B | C |
|---|---|---|---|---|
| 35-1623 | 4" | 5.24" | 2.88" | 0.13" |
| 35-1624 | 6" | 7.44" | 4.50" | 0.19" |
| 35-1625 | 8" | 9.80" | 5.25" | 0.25" |
| 35-83 | 10" | 11.81" | 6.00" | 0.32" |
| 35-84 | 12" | 14.34" | 7.50" | 0.38" |
Refer to the Technical Drawings PDF for the illustrated measurement locations of dimensions A, B, and C. Verify any additional dimensions required for installation clearance.
Product Details
Pipe End Closure
Designed to close the end of compatible SDR35 PVC sewer piping.
Five Nominal Sizes
Available in 4", 6", 8", 10", and 12" nominal sizes.
SDR35 Compatibility
Part of Tigre's SDR35 fitting program for compatible sewer and drainage systems.
PVC Construction
Manufactured from PVC compound specified for Tigre's injection-molded SDR35 fittings.
Manufacturer Dimensions
Dimensions A, B, and C are available for all five listed part numbers.
Connection Verification
Confirm the required mating connection and installation method before ordering.
Product Resources & Support
Review Tigre's SDR35 gasketed fitting specifications, technical drawings, and product catalog. Contact GetPipe.com for assistance confirming cap sizes, pipe compatibility, or manufacturer dimensions.
Frequently Asked Questions
What is an SDR35 gasketed cap?
It is a PVC fitting in Tigre's SDR35 gasketed product family, designed to close the end of compatible sewer piping.
What sizes are available?
These caps are available in 4", 6", 8", 10", and 12" nominal sizes.
What is the purpose of a sewer cap?
A sewer cap closes the end of a compatible pipe or fitting where an end termination is required.
Does the cap have a gasketed connection?
These caps are listed within Tigre's SDR35 gasketed fitting family. The supplied cap drawing does not explicitly identify the connection type. Confirm the mating connection before installation.
Are these the same as temporary plugs?
No. Tigre lists caps and temporary plugs as separate fitting types with different manufacturer part numbers.
Are these fittings injection molded?
Yes. These sizes fall within Tigre's specified 4" through 12" injection-molded SDR35 fitting range.
What material is used?
Tigre specifies virgin PVC compound with cell classification 12454 or 13343, certified to ASTM D1784, for injection-molded fittings.
What manufacturing standards apply?
Tigre identifies ASTM D3034, ASTM F1336, and CSA B182.2 as applicable SDR35 fitting standards.
Where can I find the manufacturer's dimensions?
Dimensions A, B, and C are provided above for all five part numbers. Refer to the Technical Drawings PDF for measurement locations.
Can these caps be used for compressed air or gas testing?
No. Tigre prohibits using these fittings with compressed air or gases and prohibits testing PVC piping systems with compressed air or gases.
Important Ordering & Safety Notes
Ordering: Confirm the required nominal size and manufacturer part number before ordering.
Connection Compatibility: Verify the cap's mating connection requirements and installation method with the manufacturer.
Application: Use only with compatible SDR35 PVC sewer and drainage piping systems.
Cap vs. Plug: Confirm that a cap, rather than a temporary or permanent plug, is required for the installation.
Installation: Follow Tigre's applicable installation instructions and connection requirements.
Dimensions: Review the manufacturer's technical drawing for dimensions A, B, and C before installation.
Compressed Air and Gases: Do not use these fittings for compressed air or gases. Do not test PVC piping systems with compressed air or gases.
Fluid Compatibility: Do not use these fittings with liquids not recommended by Tigre.
Warranty: Modification of fittings voids the manufacturer's warranty. Specifications are subject to change without notice.