Pro-Flex
Pro-Flex HearthMaster Log Lighter Bar - Natural Gas or LP
- Availability:
- Usually Ships in 5-7 Business Days
- Weight:
- 0.00 LBS
Description
Pro-Flex HearthMaster Log Lighter Bar - Natural Gas or LP
Pro-Flex HearthMaster Log Lighter Bars provide a convenient way to quickly start a wood-burning fireplace fire. Choose the correct model according to the fuel gas used in the installation: Natural Gas or LP / Propane.
The PF-940-10 is the Natural Gas Log Lighter Bar with 3 FIP inlets and 16 outlets, with 8 outlets on each side. The PF-941-L2 is specifically designed for LP / Propane Gas applications and features a malleable-iron mixing chamber and carbon-steel burner bar with 15 flame ports.
Product Highlights
- Pro-Flex HearthMaster fireplace log lighter bar
- Designed to help quickly start a wood-burning fireplace fire
- Natural Gas and LP / Propane configurations available
- PF-940-10 designed for Natural Gas
- PF-941-L2 designed for LP / Propane Gas only
- Fuel-specific configurations are not interchangeable
- Designed for installation with an appropriate upstream keyed gas valve
Available Gas Types
Natural Gas
- Manufacturer part number: PF-940-10
- Gas type: Natural Gas
- 3 FIP inlets
- 16 outlets total
- 8 outlets per side
LP / Propane
- Manufacturer part number: PF-941-L2
- Gas type: LP / Propane Gas only
- Malleable iron mixing chamber
- Carbon steel burner bar
- 15 flame ports
- 20" overall length
- 20,000 BTU/hr rating
Natural Gas Log Lighter
PF-940-10
The PF-940-10 HearthMaster Natural Gas Log Lighter Bar is the Natural Gas configuration in this listing. Pro-Flex identifies this model with 3 FIP inlets and 16 outlets, with 8 outlets on each side.
Select PF-940-10 only when the fireplace installation is supplied with Natural Gas.
LP / Propane Log Lighter Specifications
| Manufacturer Part Number | PF-941-L2 |
|---|---|
| Product Type | LP Gas (Propane) Log Lighter Bar |
| Approved Gas | LP (Propane) Gas Only |
| Mixing Chamber | Malleable Iron with 2 Inlet Ports |
| Burner Bar | Carbon Steel |
| Flame Ports | 15 |
| Maximum Working Pressure | 1/2 PSIG |
| Maximum Testing Pressure | 10 PSI |
| BTU/hr Rating | 20,000 |
| Overall Length | 20" |
| Mixing Chamber Length | 3-1/4" |
| Mixing Chamber Height | 2" |
| Inlet Threads | 1/2" FIP |
| Burner Bar Threads | 3/8" MIP |
LP / Propane Construction
Mixing Chamber
- Malleable iron construction
- 2 inlet ports
- 3-1/4" chamber length
- 2" chamber height
- 1/2" FIP inlet threads
Burner Bar
- Carbon steel construction
- 15 flame ports
- 3/8" MIP burner bar threads
- 20" overall assembly length
Natural Gas vs. LP / Propane
Natural Gas - PF-940-10
Use the PF-940-10 for a Natural Gas fireplace installation. Pro-Flex identifies this configuration with 3 FIP inlets and 16 outlets, 8 per side.
LP / Propane - PF-941-L2
Use the PF-941-L2 for an LP / Propane fireplace installation. Pro-Flex specifically states that the PF-941-L2 is for LP (Propane) Gas applications only.
Installation Requirements
Product installation and system testing shall be performed in accordance with NFPA 54/ANSI Z223.1 (National Fuel Gas Code), applicable state and local codes, and the manufacturer's instructions.
For the PF-941-L2 LP / Propane Log Lighter Bar, Pro-Flex specifies that a HearthMaster PF-952 or PF-954 Series keyed valve must be installed upstream within 6 feet of the log lighter.
Important: Pro-Flex states that log lighter bars may not be connected directly to CSST.
Product Documents
Pro-Flex HearthMaster PF-941-L2 LP Gas Log Lighter Spec Sheet
Review the manufacturer specification sheet for PF-941-L2 materials, approved gas, pressure ratings, BTU rating, dimensions, connection sizes, and installation requirements.
Need Help Selecting a Log Lighter?
Our industrial PVF specialists can help confirm whether your fireplace installation requires the Natural Gas or LP / Propane HearthMaster log lighter.
Frequently Asked Questions
What is a HearthMaster Log Lighter Bar used for?
A log lighter provides a convenient way to help start a wood-burning fireplace fire using the appropriate fuel gas supply.
Which model is for Natural Gas?
PF-940-10 is the Natural Gas Log Lighter Bar.
Which model is for LP / Propane?
PF-941-L2 is the LP Gas (Propane) Log Lighter Bar.
Can I use PF-941-L2 with Natural Gas?
No. Pro-Flex specifies PF-941-L2 for LP (Propane) Gas applications only.
How many outlets does PF-940-10 have?
The PF-940-10 Natural Gas Log Lighter Bar has 16 outlets, with 8 outlets on each side.
How many inlets does PF-940-10 have?
The PF-940-10 is identified with 3 FIP inlets.
What is the PF-941-L2 BTU rating?
The LP / Propane model is rated at 20,000 BTU/hr.
How long is PF-941-L2?
The manufacturer specifies a 20" overall length.
How many flame ports does PF-941-L2 have?
The carbon-steel burner bar has 15 flame ports.
Does the LP log lighter require a keyed gas valve?
Yes. Pro-Flex specifies a PF-952 or PF-954 Series HearthMaster keyed valve installed upstream within 6 feet.
Can a log lighter bar connect directly to CSST?
No. Pro-Flex states that log lighter bars may not be connected directly to CSST.
Important Ordering & Installation Notes
- Select the correct Gas Type before ordering.
- PF-940-10 is the Natural Gas configuration.
- PF-941-L2 is the LP / Propane configuration.
- PF-941-L2 is for LP (Propane) Gas only.
- Natural Gas and LP / Propane log lighters are not interchangeable.
- Log lighter bars may not be connected directly to CSST.
- Installation and testing must comply with applicable codes and manufacturer instructions.