Goss JP-19 Series Oxy-Fuel Reverse Flow Check Valves - A Fittings
Goss JP-19 Series Reverse Flow Check Valves are designed to improve safety in oxy-fuel torch systems by helping prevent the reverse flow of oxygen and fuel gases. These valves install directly at the torch inlets and provide an added layer of protection against gas backflow during welding, brazing, cutting, and heating applications.
Designed for compatibility with standard "A" size torch fittings, the JP-19 Series offers a compact, durable safety accessory for professional oxy-fuel equipment used in shop, field, HVAC, plumbing, fabrication, and maintenance environments.
Product Highlights
- Reverse flow check valves for oxy-fuel torch systems
- Helps prevent reverse flow of oxygen and fuel gases
- Installs directly at compatible torch inlets
- Compatible with standard "A" size torch fittings
- Improves overall oxy-fuel torch system safety
- Compact design for installation at the torch connection
- Durable construction for professional use
- Suitable for welding, brazing, cutting, and heating applications
- Goss JP-19 Series
Technical Specifications
| Manufacturer | Goss |
|---|---|
| Series | JP-19 Series |
| Product Type | Oxy-Fuel Reverse Flow Check Valve |
| Primary Function | Helps Prevent Reverse Flow of Oxygen and Fuel Gases |
| Installation Location | Torch Inlet |
| Fitting Size | Standard "A" Size |
| System Type | Oxy-Fuel Torch Equipment |
| Primary Applications | Welding, Brazing, Cutting and Heating |
Reverse Flow Protection
Helps Prevent Gas Backflow
The JP-19 Series is designed to help stop oxygen or fuel gas from flowing backward through the torch system, providing an additional safety measure during normal oxy-fuel operation.
Supports Safer Torch Operation
By helping control reverse gas flow, these check valves contribute to a safer overall torch setup when used with compatible oxy-fuel equipment.
Direct Torch-Inlet Installation
JP-19 Series check valves are designed to connect directly to compatible torch inlets, placing the reverse-flow protection close to the torch handle and gas-entry points.
Standard "A" Size Fittings
The valves are designed for use with standard "A" size torch fittings, making them suitable for compatible Goss oxy-fuel torch systems and other equipment using the same connection standard.
Designed for Professional Oxy-Fuel Systems
The JP-19 Series is intended for professional oxy-fuel applications where dependable gas control and added system protection are important. The valves are suitable for use in welding, brazing, cutting, heating, and related torch operations.
Common Applications
Welding & Cutting
- Oxy-fuel welding systems
- Cutting torch assemblies
- Fabrication equipment
- Shop torch setups
- Professional field service
Brazing & Heating
- Brazing torch systems
- Heating applications
- HVAC service
- Plumbing work
- Maintenance and repair
Goss Torch Equipment Catalog
Refer to the Goss Torch Equipment Catalog for additional JP-19 Series information and related Goss torch safety accessories, regulators, hoses, and oxy-fuel equipment.
California Proposition 65 Warning
WARNING: This product may expose you to chemicals, including brass and lead compounds, which are known to the State of California to cause cancer and reproductive harm. Wash hands after handling.
Need Help With Torch Safety Accessories?
Our industrial specialists can help review your torch fitting size, oxy-fuel setup, and safety accessory requirements before you order.
Frequently Asked Questions
What is the purpose of the Goss JP-19 Series?
The JP-19 Series is designed to help prevent reverse flow of oxygen and fuel gases in compatible oxy-fuel torch systems.
Where are the JP-19 Series valves installed?
They are designed to connect directly to compatible torch inlets.
What fitting size do these valves use?
The JP-19 Series is designed for standard "A" size torch fittings.
Do these valves improve torch system safety?
Yes. They provide added protection against gas backflow in compatible oxy-fuel torch systems.
Can the JP-19 Series be used for welding applications?
Yes. The valves are suitable for compatible oxy-fuel welding systems.
Can they be used for brazing and cutting?
Yes. The JP-19 Series is suitable for compatible welding, brazing, cutting, and heating applications.
Are these flashback arrestors?
The JP-19 Series is identified as a reverse flow check valve. This listing should not be interpreted as describing additional flashback-arrestor functions unless specifically stated by the manufacturer.
Important Ordering Notes
- Product family: Goss JP-19 Series.
- Product type: Oxy-fuel reverse flow check valve.
- Designed to help prevent reverse flow of oxygen and fuel gases.
- Connects directly to compatible torch inlets.
- Uses standard "A" size torch fittings.
- Suitable for compatible oxy-fuel welding, brazing, cutting, and heating systems.
- Confirm fitting size and torch compatibility before ordering.
- This listing describes reverse-flow check-valve function only.
- Follow applicable oxy-fuel, torch, hose, regulator, and workplace safety procedures.
- Refer to the Goss Torch Equipment Catalog for additional product information.