Goss 450 PSI Nitrogen Regulator CGA 580 x 1/4" Male Flare

Goss EN-450F Nitrogen Regulator is a professional-grade high-pressure regulator designed for controlled nitrogen delivery in HVAC, refrigeration, plumbing, and industrial service applications. With a maximum outlet pressure of 450 PSI, the EN-450F is well suited for high-pressure purging, pressure testing, and other nitrogen-service tasks requiring accurate outlet control.

The regulator features a standard CGA 580 nitrogen cylinder inlet, a 1/4" male flare outlet, dual 2" gauges, and a heavy-duty brass body for durable professional use. A precision adjustment knob allows the operator to fine-tune delivery pressure for the application.

Product Highlights

  • Professional high-pressure nitrogen regulator
  • Designed specifically for nitrogen service
  • Maximum outlet pressure of 450 PSI
  • Standard CGA 580 nitrogen cylinder inlet connection
  • 1/4" male flare outlet connection
  • Dual 2" gauges for inlet and outlet pressure monitoring
  • Heavy-duty brass body for long service life
  • Precision pressure adjustment knob
  • Suitable for purging, pressure testing, HVAC, refrigeration, plumbing, and industrial service
  • Manufacturer part number EN-450F

Technical Specifications

Manufacturer Goss
Part Number EN-450F
Product Type High-Pressure Nitrogen Regulator
Gas Service Nitrogen
Maximum Outlet Pressure 450 PSI
Inlet Connection CGA 580
Outlet Connection 1/4" Male Flare
Gauge Configuration Dual 2" Gauges
Gauge Functions Inlet Pressure and Outlet Pressure
Body Construction Heavy-Duty Brass
Pressure Adjustment Precision Adjustment Knob
Primary Applications HVAC, Refrigeration, Plumbing, Purging, Pressure Testing and Industrial Service

High-Pressure Nitrogen Control

Up to 450 PSI Outlet Pressure

The EN-450F supports outlet pressures up to 450 PSI, making it suitable for higher-pressure nitrogen applications such as system testing and purging where controlled delivery pressure is required.

Precision Adjustment

A dedicated pressure adjustment knob allows the operator to regulate nitrogen delivery and set outlet pressure according to the requirements of the application.

Dual-Gauge Monitoring

Inlet Pressure Gauge

One 2" gauge provides visibility of nitrogen-cylinder inlet pressure so the operator can monitor the available supply during use.

Outlet Pressure Gauge

The second 2" gauge displays regulated outlet pressure, providing a clear reference for nitrogen pressure being delivered downstream.

CGA 580 Nitrogen Connection

The regulator uses a standard CGA 580 inlet connection designed for compatible nitrogen cylinders. Confirm that the cylinder valve and regulator connection match before installation.

1/4" Male Flare Outlet

The EN-450F uses a 1/4" male flare outlet connection for attachment to compatible nitrogen hoses, service equipment, and downstream fittings commonly used in HVAC and refrigeration work.

Common Applications

HVAC & Refrigeration

  • Nitrogen purging
  • Pressure testing
  • Refrigeration service
  • HVAC installation and maintenance
  • System leak-check preparation

Plumbing & Industrial Service

  • Controlled nitrogen delivery
  • Pressure testing
  • Industrial maintenance
  • General nitrogen-service applications
  • Field and shop service work

Heavy-Duty Brass Construction

The Goss EN-450F features a heavy-duty brass regulator body designed for durable service in professional HVAC, refrigeration, plumbing, and industrial environments.

Regulator Selection Considerations

Confirm that the required nitrogen pressure, cylinder connection, downstream fitting, hose, and service equipment are compatible with the EN-450F before ordering. The regulator is designed specifically for nitrogen service, with a CGA 580 inlet and 1/4" male flare outlet.

Goss Torch Equipment Catalog

Refer to the Goss Torch Equipment Catalog for additional EN-450F information, regulator specifications, compatible fittings, and related Goss nitrogen-service equipment.

California Proposition 65 Warning

WARNING: This product may expose you to chemicals, including brass and lead compounds, which are known to the State of California to cause cancer and reproductive harm. Wash hands after handling.

Need Help Selecting a Nitrogen Regulator?

Our industrial specialists can help review your required nitrogen pressure, cylinder connection, outlet fitting, hose setup, and HVAC or refrigeration service application before you order.

Frequently Asked Questions

What is the Goss EN-450F used for?

The EN-450F is designed for controlled nitrogen delivery in HVAC, refrigeration, plumbing, purging, pressure testing, and industrial service applications.

What is the maximum outlet pressure of the EN-450F?

The maximum outlet pressure is 450 PSI.

What cylinder connection does the EN-450F use?

The regulator uses a CGA 580 inlet connection for compatible nitrogen cylinders.

What outlet connection does the EN-450F have?

The outlet connection is 1/4" male flare.

How many gauges are included?

The EN-450F includes two 2" gauges for monitoring inlet and regulated outlet pressure.

What is the regulator body made from?

The regulator features a heavy-duty brass body designed for professional service.

Can the EN-450F be used for HVAC pressure testing?

Yes. Pressure testing is one of the intended nitrogen-service applications for the EN-450F.

Can the EN-450F be used for nitrogen purging?

Yes. The regulator is suitable for controlled nitrogen purging applications.

How is outlet pressure adjusted?

The EN-450F uses a precision pressure adjustment knob to control regulated nitrogen delivery pressure.

Important Ordering Notes

  • Manufacturer part number: EN-450F.
  • Designed specifically for nitrogen service.
  • Maximum outlet pressure is 450 PSI.
  • Inlet connection is CGA 580.
  • Outlet connection is 1/4" male flare.
  • Includes dual 2" gauges for inlet and outlet pressure monitoring.
  • Features a heavy-duty brass regulator body.
  • Uses a precision pressure adjustment knob.
  • Confirm nitrogen cylinder, hose, flare connection, and downstream equipment compatibility before ordering.
  • Use only with compatible nitrogen-service equipment.
  • Follow applicable compressed-gas, regulator, pressure-testing, and workplace safety procedures.
  • Refer to the Goss Torch Equipment Catalog for additional product information.