Gasoila Leak-Tech Extreme Temperature Leak Detector
Gasoila® Leak-Tech Extreme Temperature Leak Detector is engineered for detecting leaks in compatible gas-carrying systems, including natural gas lines, gas cylinders, refrigeration condensers, air lines, air pumps, and other systems carrying gas.
Designed for extreme-temperature applications, Leak-Tech has a listed temperature range of -10°F (-23°C) to 350°F (177°C). Apply Leak-Tech directly to the area being tested and observe for bubble formation to help pinpoint escaping gas.
Product Highlights
- Extreme-temperature liquid leak detector
- Designed for compatible gas-carrying systems
- For natural gas lines and gas cylinders
- For refrigeration condensers
- For compatible air lines and air pumps
- Temperature range: -10°F (-23°C) to 350°F (177°C)
- Bubble formation helps pinpoint escaping gas
- Available in dauber, spray bottle, gallon, and bulk drum formats
- Not for use with FlowGuard Gold piping systems
- Do not use on oxygen systems
- Manufactured by Federal Process Corporation
Available Leak-Tech Options
| Part Number | Package | Units Per Case | Case Weight |
|---|---|---|---|
| LT08 | 8 oz with Dauber | 12 | 9 lb |
| LS16 | 1 Pint Spray Bottle | 12 | 17 lb |
| LT28 | 1 Gallon Bottle | 4 | 38 lb |
| LT55 | 55 Gallon Drum | 1 | 440 lb |
Technical Specifications
| Brand | Gasoila |
|---|---|
| Manufacturer | Federal Process Corporation |
| Product | Gasoila® Leak-Tech |
| Product Type | Leak Detector |
| Physical State | Liquid |
| Appearance | Clear Liquid |
| Color | Red |
| Odor | Mild |
| pH | 7.50 |
| Temperature Range | -10°F (-23°C) to 350°F (177°C) |
| Typical Applications | Natural Gas Lines, Gas Cylinders, Refrigeration Condensers, Air Lines, Air Pumps and Other Compatible Gas-Carrying Systems |
| FlowGuard Gold | Not for Use |
| Oxygen Systems | Do Not Use |
| Shelf Life | 1 Year from Date of Manufacture |
8 oz with Dauber
LT08
- 8 oz container with dauber applicator
- Manufacturer part number LT08
- 12 units per case
- 9 lb listed case weight
- Estimated individual shipping weight: 0.75 lb
- Dauber applicator allows controlled placement directly onto the area being tested
- Convenient size for service technicians, maintenance kits, and field use
1 Pint Spray Bottle
LS16
- 1 pint spray bottle
- Manufacturer part number LS16
- 12 units per case
- 17 lb listed case weight
- Estimated individual shipping weight: 1.42 lb
- Trigger-spray format provides convenient application over larger test areas
- Useful where spray application is preferred over a dauber
1 Gallon Bottle
LT28
- 1 gallon bottle
- Manufacturer part number LT28
- 4 units per case
- 38 lb listed case weight
- Estimated individual shipping weight: 9.50 lb
- Large-volume package for regular shop, service, maintenance, and industrial use
55 Gallon Drum
LT55
- 55 gallon drum
- Manufacturer part number LT55
- 1 drum per case
- 440 lb listed case weight
- Shipping weight: 440.00 lb
- Bulk package for high-volume industrial and maintenance applications
- Freight-size item
Designed for Gas Leak Detection
Natural Gas Systems
Gasoila Leak-Tech is engineered for leak testing on compatible natural gas lines and related gas-carrying systems.
Refrigeration Applications
Refrigeration condensers are among the applications identified for Leak-Tech Extreme Temperature Leak Detector.
Air Systems
Leak-Tech may also be used on compatible air lines, air pumps, and other systems carrying gas.
Extreme Temperature Performance
Gasoila Leak-Tech Extreme Temperature Leak Detector is designed for use across a listed temperature range of -10°F (-23°C) to 350°F (177°C).
This broad temperature range makes Leak-Tech useful for leak-testing applications where piping and equipment may be exposed to demanding operating temperatures.
How Leak-Tech Works
1. Apply Leak-Tech
Shake well before use. Liberally apply Gasoila® Leak-Tech directly to the area being tested.
2. Watch for Bubbles
Escaping gas causes the product to bubble, helping pinpoint the location of the leak. According to the supplied product directions, the bubbles remain for approximately ten minutes.
Directions for Use
- Shake well before using.
- Do not dilute or alter the product.
- Liberally apply Gasoila Leak-Tech directly to the area being tested.
- Observe the test area for bubble formation.
- Bubble formation helps pinpoint the location of escaping gas.
- Follow all current manufacturer directions and safety instructions.
Important Application Restrictions
Do Not Use on Oxygen Systems
Do not use Gasoila Leak-Tech on oxygen systems. Verify the system and intended application before use.
Not for FlowGuard Gold
Gasoila Leak-Tech is not for use with FlowGuard Gold piping systems. Confirm piping-system compatibility before application.
Safety & Handling
- Keep out of reach of children.
- Do not breathe mist, vapors, or spray.
- Wash hands thoroughly after handling.
- Do not eat, drink, or smoke when using this product.
- Avoid contact with eyes.
- Do not swallow.
- Ensure adequate ventilation, particularly in confined areas.
- Keep the container tightly closed when stored.
- Store in a dry, cool, well-ventilated location.
- Review the complete current Safety Data Sheet before handling or use.
SDS Hazard Information
The Safety Data Sheet uses the signal word Warning and identifies hazards including harmful if swallowed, serious eye irritation, and potential organ damage through prolonged or repeated exposure.
Review the complete Safety Data Sheet for current precautions, first-aid measures, handling requirements, storage information, exposure controls, and disposal instructions.
Physical Properties
| Physical State | Liquid |
|---|---|
| Appearance | Clear Liquid |
| Color | Red |
| Odor | Mild |
| pH | 7.50 |
| Specific Gravity | 1.015 |
| Water Solubility | Soluble |
| Flash Point | None Listed |
Selecting the Correct Size
8 oz Dauber or 1 Pint Spray
Select LT08 when controlled dauber application is preferred. Select LS16 when a trigger-spray bottle is more convenient for applying Leak-Tech across larger or harder-to-reach test areas.
1 Gallon or 55 Gallon
Select LT28 for higher-volume shop and maintenance requirements. Select LT55 for bulk industrial applications requiring a 55 gallon drum.
Before Use
- Confirm compatibility with the piping, equipment, and system being tested.
- Do not use on oxygen systems.
- Do not use with FlowGuard Gold piping systems.
- Shake well before application.
- Do not dilute or alter Leak-Tech.
- Review the current Safety Data Sheet before handling or use.
- Follow manufacturer instructions for handling, application, storage, first aid, and disposal.
Safety Data Sheet
Review the current Gasoila® Leak-Tech Safety Data Sheet before handling or using this product. Follow all manufacturer safety, handling, application, storage, first-aid, and disposal instructions.
Need Help Selecting a Leak Detector?
Our industrial PVF specialists can help review system type, operating temperature, package size, application method, and Gasoila Leak-Tech compatibility before you order.
Frequently Asked Questions
What is Gasoila Leak-Tech?
Gasoila® Leak-Tech is a liquid leak detector designed for use on compatible gas-carrying systems.
What product numbers are covered by the Leak-Tech Safety Data Sheet?
The Gasoila Leak-Tech Safety Data Sheet identifies product codes LT08, LS16, LT28, and LT55.
What systems can Leak-Tech be used on?
The supplied product information identifies natural gas lines, gas cylinders, refrigeration condensers, air lines, air pumps, and other compatible systems carrying gas.
What is the temperature range?
The supplied product information lists a temperature range of -10°F (-23°C) to 350°F (177°C).
How does Leak-Tech indicate a leak?
Leak-Tech is applied directly to the area being tested. Escaping gas causes bubbles to form, helping pinpoint the location of the leak.
How long do the bubbles remain?
The supplied product directions state that bubbles remain for approximately ten minutes.
Should Gasoila Leak-Tech be diluted?
No. The supplied directions warn that dilution or alteration may lead to failure of the product and its intended application.
Can Leak-Tech be used on oxygen systems?
No. Do not use Gasoila Leak-Tech on oxygen systems.
Can Leak-Tech be used with FlowGuard Gold piping?
No. The supplied product information states that Leak-Tech is not for use with FlowGuard Gold piping systems.
What is LT08?
LT08 is the 8 oz with Dauber version of Gasoila Leak-Tech.
What is LS16?
LS16 is the 1 Pint Spray Bottle version of Gasoila Leak-Tech.
What is LT28?
LT28 is the 1 Gallon Bottle version of Gasoila Leak-Tech.
What is LT55?
LT55 is the 55 Gallon Drum version of Gasoila Leak-Tech.
What is the shelf life?
The supplied product information states a shelf life of one year from the date of manufacture.
What safety hazards are identified in the SDS?
The SDS uses the signal word Warning and identifies hazards including harmful if swallowed, serious eye irritation, and potential organ damage through prolonged or repeated exposure. Review the complete current SDS before use.
Where can I find the Safety Data Sheet?
The PDF Safety Data Sheet is linked in the Safety Data Sheet section directly above. A Word document version can also be linked there once it has a public website or CDN URL.
Are the individual shipping weights exact manufacturer unit weights?
The individual shipping weights shown in this listing are calculated from the supplied case weights and units-per-case quantities for catalog and shipping purposes.
Important Ordering Notes
- LT08: 8 oz with Dauber.
- LS16: 1 Pint Spray Bottle.
- LT28: 1 Gallon Bottle.
- LT55: 55 Gallon Drum.
- LT55 is a freight-size bulk item.
- Temperature range: -10°F (-23°C) to 350°F (177°C).
- Do not use on oxygen systems.
- Not for use with FlowGuard Gold piping systems.
- Do not dilute or alter the product.
- Review the current Safety Data Sheet before handling or use.
- Follow current manufacturer application and safety instructions.